Plan Review Stops For Permit 20081406 |
Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
Rev No |
1 |
Status |
N |
Date |
2020-09-28 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-09-28 |
Time |
14:35 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-09-28 |
Time |
14:34 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2021-01-13 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-01-13 |
Time |
09:12 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-01-13 |
Time |
09:12 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2020-12-16 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-12-16 |
Time |
15:49 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-12-16 |
Time |
15:49 |
Sent To |
|
|
Notes |
2020-12-16 16:01:41 | ADD RESTROOM | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected] | | CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1 | | AMENDMENTS | | | | 3RD REVIEW | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | 1) PLEASE SHOW THE BUILDING USE (OCCUPANCY | | CLASSIFICATION PER FBC CHAPTER 3. | | 2) PLEASE SHOW THE RESTROOM WALL AND FLOOR FINISHES TO | | COMPLY WITH FBC 1210.2 (DRYWALL IS NOT CONSIDERED A | | HARD SURFACE) | | 3) PLEASE SHOW THE BOTTOM OF THE MIRROR REFLECTION TO | | THE FINISHED FLOOR TO COMPLY WITH FBC ACCESSIBILITY | | 603.3 MIRRORS. | | MIRRORS LOCATED ABOVE LAVATORIES OR COUNTERTOPS SHALL | | BE INSTALLED WITH THE BOTTOM EDGE OF THE REFLECTING | | SURFACE 40 INCHES (1015 MM) MAXIMUM ABOVE THE FINISH | | FLOOR OR GROUND. | | 4) THE TOILET PAPER DISPENSER = SEE FBC ACCESSIBILITY | | FIGURE 604.7 | | 5) PLEASE SHOW THE BUILDING EXIT DOOR AND THE RESTROOM | | DOOR MANUVERING CLEARANCE TO COMPLY WITH FBC | | ACCESSIBILITY 404.2.4 SEE FIGURE 404.2.4.1 | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2020-10-29 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-10-29 |
Time |
14:43 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-10-29 |
Time |
14:28 |
Sent To |
|
|
Notes |
2020-10-29 14:43:21 | ADD RESTROOM | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected] | | CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1 | | AMENDMENTS | | | | 2ND REVIEW | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | 1) PLEASE SHOW THE BUILDING USE (OCCUPANCY | | CLASSIFICATION PER FBC CHAPTER 3. | | 2) PLEASE SHOW THE WALL AND FLOOR FINISHES TO COMPLY | | WITH FBC 1210.2 (DRYWALL IS NOT CONSIDERED A HARD | | SURFACE) | | 3) PLEASE SHOW THE BOTTOM OF THE MIRROR REFLECTION TO | | THE FINISHED FLOOR TO COMPLY WITH FBC ACCESSIBILITY | | 603.3 MIRRORS. | | MIRRORS LOCATED ABOVE LAVATORIES OR COUNTERTOPS SHALL | | BE INSTALLED WITH THE BOTTOM EDGE OF THE REFLECTING | | SURFACE 40 INCHES (1015 MM) MAXIMUM ABOVE THE FINISH | | FLOOR OR GROUND. | | 4) THE 36" GRAB BAR ON THE BACK WALL OF THE WATER | | CLOSET = 24" AND 12" NEED TO BE SHOWN FROM THE CENTER | | LINE OF THE WATER CLOSET SEE FBC ACCESSIBILITY FIGURE | | 604.5.2 | | 5) THE TOILET PAPER DISPENSER = THE 7" TO 9" NEEDS TO | | BE SHOWN TO THE CENTER OF THE DISPENSER SEE FBC | | ACCESSIBILITY FIGURE 604.7 | | 6) PLEASE SHOW THE BUILDING EXIT DOOR AND THE RESTROOM | | DOOR MANUVERING CLEARANCE TO COMPLY WITH FBC | | ACCESSIBILITY 404.2.4 SEE FIGURE 404.2.4.1 | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2020-09-28 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-09-28 |
Time |
14:34 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-09-28 |
Time |
13:56 |
Sent To |
|
|
Notes |
2020-09-28 14:34:25 | ADD RESTROOM | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected] | | CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1 | | AMENDMENTS | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | 1) PLEASE SHOW THE BUILDING USE (OCCUPANCY | | CLASSIFICATION PER FBC CHAPTER 3. | | 2) PLEASE SHOW THE WALL AND FLOOR FINISHES TO COMPLY | | WITH FBC 1210.2 (DRYWALL IS NOT CONSIDERED A HARD | | SURFACE) | | 3) DOOR CANNOT SWING INTO THE PATH OF EGRESS FBC | | 1005.7.1 DOORS. | | DOORS, WHEN FULLY OPENED, SHALL NOT REDUCE THE REQUIRED | | WIDTH BY MORE THAN 7 INCHES (178 MM). DOORS IN ANY | | POSITION SHALL NOT REDUCE THE REQUIRED WIDTH BY MORE | | THAN ONE-HALF. | | 4) PLEASE SHOW THE BOTTOM OF THE MIRROR REFLECTION TO | | THE FINISHED FLOOR TO COMPLY WITH FBC ACCESSIBILITY | | 603.3 MIRRORS. | | MIRRORS LOCATED ABOVE LAVATORIES OR COUNTERTOPS SHALL | | BE INSTALLED WITH THE BOTTOM EDGE OF THE REFLECTING | | SURFACE 40 INCHES (1015 MM) MAXIMUM ABOVE THE FINISH | | FLOOR OR GROUND. | | 5) PLEASE SHOW THE BUILDING EXIT DOOR MANUVERING | | CLEARANCE TO COMPLY WITH FBC ACCESSIBILITY 404.2.4 | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2020-12-16 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2020-12-16 |
Time |
09:20 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2020-12-16 |
Time |
09:20 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2020-11-02 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2020-11-02 |
Time |
11:25 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2020-11-02 |
Time |
11:23 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2020-09-23 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2020-09-23 |
Time |
15:07 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2020-09-23 |
Time |
15:04 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2020-12-10 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2020-12-10 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2020-12-10 |
Time |
16:05 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2020-10-22 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2020-10-22 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2020-10-22 |
Time |
13:43 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2020-09-15 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2020-09-15 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2020-09-15 |
Time |
10:43 |
Sent To |
|
|
Notes |
2020-09-15 10:51:57 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED | | AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE | | PROVISO COMMENTS WILL RESULT IN A FAILED FIRE | | INSPECTION. | | | | | | 1) THE BATHROOM DOOR IS INDICATED AS OPENING INTO THE | | PATH OF EGRESS. THE BATHROOM DOOR SHALL NOT BLOCK THE | | EXTERIOR EXIT DOOR. | | | | DOES THAT EXTERIOR DOOR HAVE AN EXIT SIGN OVER IT | | AND/OR IS IT A REQUIRED EXIT DOOR? SOME BUSINESSES CAN | | HAVE A SINGLE EXIT (FRONT DOOR) IF IT MEETS THE CODE | | REQUIRMENTS FOR A SINGLE EXIT. | | | | PER NFPA 101 CHAPTER 7, MEANS OF EGRESS | | | | 7.2.1.4.3 DOOR LEAF ENCROACHMENT | | 7.2.1.4.3.1 DURING ITS SWING, ANY DOOR LEAF IN A MEANS | | OF EGRESS SHALL | | LEAVE NOT LESS THAN ONE-HALF OF THE REQUIRED WIDTH OF | | AN AISLE, A CORRIDOR, A | | PASSAGEWAY, OR A LANDING UNOBSTRUCTED AND SHALL NOT | | PROJECT NOT MORE THAN | | 7 IN. INTO THE REQUIRED WIDTH OF AN AISLE, A CORRIDOR, | | A PASSAGE WAY, OR A | | LANDING, WHEN FULLY OPEN, UNLESS BOTH OF THE FOLLOWING | | CONDITIONS ARE MET: | | (1) THE DOOR OPENING PROVIDES ACCESS TO A STAIR IN AN | | EXISTING BUILDING. | | (2) THE DOOR OPENING MEETS THE REQUIREMENTS THAT LIMITS | | PROJECTION TO | | NOT MORE THAN 7 IN. INTO THE REQUIRED WIDTH OF THE | | STAIR LANDING | | WHEN THE DOOR LEAF IS FULLY OPEN. | | | | NFPA 101 CH 39 EXISTING BUSINESS | | | | 39.2.4.2 EXIT ACCESS, AS REQUIRED BY 39.2.4.1(3), SHALL | | BE PERMITTED | | TO INCLUDE A SINGLE EXIT ACCESS PATH FOR THE DISTANCES | | PERMITTED AS | | COMMON PATHS OF TRAVEL BY 39.2.5.3. | | | | 39.2.4.3 A SINGLE EXIT SHALL BE PERMITTED FOR A ROOM OR | | AREA WITH A | | TOTAL OCCUPANT LOAD OF LESS THAN 100 PERSONS, PROVIDED | | THAT ALL OF | | THE FOLLOWING CRITERIA ARE MET: | | (1) THE EXIT SHALL DISCHARGE DIRECTLY TO THE OUTSIDE AT | | THE LEVEL OF | | EXIT DISCHARGE FOR THE BUILDING. | | (2) THE TOTAL DISTANCE OF TRAVEL FROM ANY POINT, | | INCLUDING TRAVEL | | WITHIN THE EXIT, SHALL NOT EXCEED 100 FT (30 M). | | (3) THE TOTAL DISTANCE OF TRAVEL SPECIFIED IN | | 39.2.4.3(2) SHALL BE | | ON THE SAME STORY, OR, IF TRAVERSING OF STAIRS IS | | NECESSARY, SUCH | | STAIRS SHALL NOT EXCEED 15 FT (4570 MM) IN HEIGHT, AND | | BOTH OF | | THE FOLLOWING ALSO SHALL APPLY: | | (A) INTERIOR STAIRS SHALL BE PROVIDED WITH COMPLETE | | ENCLOSURES TO SEPARATE THEM FROM ANY OTHER PART OF THE | | BUILDING, WITH NO DOOR OPENINGS THEREIN. | | (B) A SINGLE OUTSIDE STAIR IN ACCORDANCE WITH 7.2.2 | | SHALL BE | | PERMITTED TO SERVE ALL STORIES PERMITTED WITHIN THE 15 | | FT | | (4570 MM) VERTICAL TRAVEL LIMITATION. | | | | IF THAT EXIT DOOR IS A REQUIRED EXIT THEN THE BATHROOM | | DOOR SHALL NOT OPEN OUT TO BLOCK THE EXIT. THE DOOR | | SHALL SWING INTO THE BATHROOM. | | | | IF THERE IS AN EXIT SIGN OVER THE DOOR BUT IS NOT A | | REQUIRED EXIT, REMOVE THE EXIT SIGN AND THE DOOR CAN | | REMAIN SWINGING OUT. | | | | THE FIRE INSPECTOR WITH VERIFY ON INSPECTION. | | | | PLEASE ENSURE COMPLIANCE. | | | | | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2021-01-13 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-01-13 |
Time |
09:13 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-01-13 |
Time |
08:30 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2021-01-07 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2021-01-07 |
Time |
08:54 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2020-12-09 |
Time |
07:35 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2020-11-03 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2020-11-03 |
Time |
09:42 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2020-10-21 |
Time |
07:28 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2020-09-28 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-09-28 |
Time |
14:36 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-09-11 |
Time |
11:04 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
P |
Date |
2021-01-13 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2021-01-13 |
Time |
08:11 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2021-01-13 |
Time |
08:11 |
Sent To |
|
|
Notes |
2021-01-13 08:12:13 | 01/13/21 REVIEWED FOR CODE COMPLIANCE (PLUMBING) | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES | | FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, | | STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT | | THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK | | OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | AVOID VOIDING OF THE PERMIT. | | | | LUIS A. CRESPO | | PLUMBING PLAN EXAMINER / INSPECTOR | | EMAIL: [email protected] OFFICE: 561 805-6720 | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
F |
Date |
2021-01-07 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2021-01-07 |
Time |
08:50 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2020-12-29 |
Time |
16:11 |
Sent To |
|
|
Notes |
2021-01-07 08:55:08 | 01/07/20 3RD PLUMBING REVIEW**DENIED** WITH COMMENTS | | | | NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS | | TIME, AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE | | GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS. | | | | THIS IS THE THIRD PLAN REVIEW THAT HAS NOT PASSED. | | PLEASE GET WITH THE PLAN REVIEWER AND MAKE AN | | APPOINTMENT TO COME INTO THE BUILDING DEPARTMENT TO | | EXPLAIN WHAT IS NEEDED. | | | | 1. PLEASE SHOW THE BUILDING USE (OCCUPANCY | | CLASSIFICATION PER FBC CHAPTER 3. | | | | 2. PLEASE SHOW THE WALL AND FLOOR FINISHES TO COMPLY | | WITH FBC 1210.2.2. EPOXY PAINT ON DRYWALL DOES NOT MEET | | THE INTENT OF THE CODE. | | | | 3. PLEASE SHOW THE BOTTOM OF THE MIRROR'S REFLECTIVE | | SURFACE TO THE FINISHED FLOOR TO COMPLY WITH FBC | | ACCESSIBILITY 603.3 MIRRORS, NOT THE MIRROR'S FRAME. | | | | 4. THE 24" AND 12" ON THE GRAB BAR BEHIND THE TOILET | | NEED TO BE SHOWN FROM THE CENTERLINE OF THE WATER | | CLOSET, NOT TO THE EDGE OF THE TOILET SEE FBC | | ACCESSIBILITY FIGURE 604.5.2. | | | | 5. TOILET PAPER DISPENSER - THE 7" TO 9" NEEDS TO BE | | SHOWN TO THE CENTER OF THE DISPENSER, REMOVE THE 9?? | | AND PUT 15? TO TOP OF DISPENSER SEE FBC ACCESSIBILITY | | FIGURE 604.7. | | | | 6. PLEASE SHOW THE REQUIRED CLEAR FLOOR SPACE AND | | DIMENSIONS FOR THE TOILET AND LAVATORY IN THE TOILET | | ROOM PER FBC-ACCESS. SECS. 604.3.1 AND FIGURE 604.3.1 | | AND 606..2 AND SECS.305 & 306. | | | | WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION & | | REMOVE ANY VOIDED SHEETS & REPLACE ANY NECESSARY PAGES. | | A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | HTTPS://CODES.ICCSAFE.ORG/CODES/FLORIDA | | | | LUIS A. CRESPO | | PLUMBING PLAN EXAMINER / INSPECTOR | | EMAIL: [email protected] OFFICE: 561 805-6720 | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2020-11-03 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2020-11-03 |
Time |
09:42 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2020-11-03 |
Time |
09:04 |
Sent To |
|
|
Notes |
2020-11-03 09:42:34 | | | 1) PLEASE SHOW THE BUILDING USE (OCCUPANCY | | CLASSIFICATION PER FBC CHAPTER 3. | | 2) PLEASE SHOW THE WALL AND FLOOR FINISHES TO COMPLY | | WITH FBC 1210.2.2. EPOXY PAINT ON DRYWALL DOES NOT MEET | | THE INTENT OF THE CODE. | | 3) PLEASE SHOW THE BOTTOM OF THE MIRROR'S REFLECTIVE | | SURFACE TO THE FINISHED FLOOR TO COMPLY WITH FBC | | ACCESSIBILITY 603.3 MIRRORS. | | MIRRORS LOCATED ABOVE LAVATORIES OR COUNTERTOPS SHALL | | BE INSTALLED WITH THE BOTTOM EDGE OF THE REFLECTING | | SURFACE 40 INCHES (1015 MM) MAXIMUM ABOVE THE FINISH | | FLOOR OR GROUND. | | 4) THE 24" AND 12" ON THE GRAB BAR BEHIND THE TOILET | | NEED TO BE SHOWN FROM THE CENTER LINE OF THE WATER | | CLOSET SEE FBC ACCESSIBILITY FIGURE 604.5.2 | | 5) TOILET PAPER DISPENSER - THE 7" TO 9" NEEDS TO BE | | SHOWN TO THE CENTER OF THE DISPENSER SEE FBC | | ACCESSIBILITY FIGURE 604.7 | | 6) THE LOCATION OF THE GRAB BAR ADJACENT TO THE TOILET | | SHALL COMPLY WITH FBC-ACCESS. SEC.604.5.1 & FIGURE | | 604.5.1. | | 7) THE SIDE ELEVATION STILL SHOWS THE GRAB BAR MEASURED | | TO THE CENTERLINE OF THE BAR. THE BAR SHALL BEE MEASURE | | TO THE TOP OF THE GRIPPING SURFACE. FBS- ACCESS. | | 609..4. | | 8) SHOW THE REQUIRED CLEAR FLOOR SPACE DIMENSIONS FOR | | THE TOILET AND LAVATORY IN THE TOILET ROOM PER | | FBC-ACCESS. SECS. 604.3.1 AND FIGURE 604.3.1 AND 606..2 | | AND SECS.305 & 306. | | | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | CITY OF WEST PALM BEACH | | 561-805-6692; [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2020-09-16 |
|
|
Cont ID |
|
Sent By |
abelisle |
Date |
2020-09-16 |
Time |
19:09 |
Rev Time |
0.00 |
Received By |
abelisle |
Date |
2020-09-16 |
Time |
18:14 |
Sent To |
|
|
Notes |
2020-09-16 18:14:33 | 1ST REVIEW FBC-2017 PLUMBING | | PERMIT-20081406 | | 9/16/2020 | | | | CODES IN EFFECT: | | | | FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017 | | FBC ACC- FLORIDA ACCESSIBILITY CODE SIXTH ADDITION 2017 | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | 2017 | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | 2017 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2017 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1. A SUB PLUMBING PERMIT IS REQUIRED BY A LICENSED | | CONTRACTOR FOR THE SCOPE OF WORK PER THE WPB AMENDMENTS | | TO THE FBC SEC. 105.1. | | | | 2. SUBMIT A SLAB REPAIR DETAIL FOR REVIEW. SHOW THE | | WIDTH OF THE REPAIR, THE MINIMUM THICKNESS OF THE | | CONCRETE TO BE REPLACED, AND THE PSI OF THE CONCRETE. | | SHOW THE SIZE AND LENGTH OF THE DOWELS, THE MINIMUM | | EMBEDMENT DEPTH INTO THE EXISTING SLAB, AND THE SPACING | | OF THE DOWELS ON THE CENTER. THE REPAIR SHALL ALSO | | INCLUDE TERMITE TREATMENT OF THE SOIL AND THE REQUIRED | | VAPOR BARRIER OVER THE SOIL. A COPY OF THE TERMITE | | CERTIFICATE SHALL BE ONSITE FOR A FINAL INSPECTION. | | | | 3. PLEASE PROVIDE WHAT TYPE OF OCCUPANCY THIS INTERIOR | | BUILD-OUT WILL BE AND THE OCCUPANCY LOAD WPB AMENDMENTS | | TO THE FBC SEC. 107.2.1 INFORMATION ON CONSTRUCTION | | DOCUMENTS. | | | | 4. THERE IS MEASUREMENT DISCREPANCIES ON THE GRAB BAR | | LOCATIONS AND THE TOILET PAPER LOCATION PLEASE REFER TO | | FBC ACC 603, FBC ACC 604.5.1 FBC ACC 604.7 | | | | 5. DOOR CANNOT SWING OUT AND OBSTRUCT LIFESAFETY TRAVEL | | PATH TO THE EXIT REAR DOOR FBC ACC 603.2.3 | | | | 6. THE PLUMBING PLAN SHALL BEAR THE TITLE BLOCK AND | | ELECTRONIC SEAL AND SIGNATURE OF THE FL. LICENSED | | ARCHITECT OR ENGINEER WHO PREPARED THE DRAWING- SECTION | | 107.2.1 WPB, FL. STATUTES 471.025 & 481.221, AND | | SECTIONS 61G15-23.005 & 61G1-16.005 FAC. | | CONTRACTOR- DRAWN PLANS SHALL BEAR THE TITLE BLOCK, | | LICENSE NUMBER, AND SIGNATURE OF THE FL. LICENSED | | CONTRACTOR OR QUALIFIER WHO PREPARED THE DRAWING- | | SECTION 107.2.1 WPB. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | ATELYO BELISLE | | PLUMBING INSPECTOR / | | PLUMBING PLAN REVIEW | | AVAILABLE FROM 1:00 PM TO 4:00 PM | | [email protected] | | 561-805-6695 | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
N |
Date |
2020-12-16 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-12-16 |
Time |
16:01 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-12-16 |
Time |
16:01 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
N |
Date |
2020-10-29 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-10-29 |
Time |
14:43 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-10-29 |
Time |
14:43 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
N |
Date |
2020-09-28 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-09-28 |
Time |
14:36 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-09-28 |
Time |
14:36 |
Sent To |
|
|
Notes |
|
|