Plan Review Details - Permit 20081406
Plan Review Stops For Permit 20081406
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status N Date 2020-09-28 Cont ID  
Sent By rmcphers Date 2020-09-28 Time 14:35 Rev Time 0.00
Received By rmcphers Date 2020-09-28 Time 14:34 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2021-01-13 Cont ID  
Sent By rmcphers Date 2021-01-13 Time 09:12 Rev Time 0.00
Received By rmcphers Date 2021-01-13 Time 09:12 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2020-12-16 Cont ID  
Sent By rmcphers Date 2020-12-16 Time 15:49 Rev Time 0.00
Received By rmcphers Date 2020-12-16 Time 15:49 Sent To  
Notes
2020-12-16 16:01:41ADD RESTROOM
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1
 AMENDMENTS
  
 3RD REVIEW
  
 CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107
 1) PLEASE SHOW THE BUILDING USE (OCCUPANCY
 CLASSIFICATION PER FBC CHAPTER 3.
 2) PLEASE SHOW THE RESTROOM WALL AND FLOOR FINISHES TO
 COMPLY WITH FBC 1210.2 (DRYWALL IS NOT CONSIDERED A
 HARD SURFACE)
 3) PLEASE SHOW THE BOTTOM OF THE MIRROR REFLECTION TO
 THE FINISHED FLOOR TO COMPLY WITH FBC ACCESSIBILITY
 603.3 MIRRORS.
 MIRRORS LOCATED ABOVE LAVATORIES OR COUNTERTOPS SHALL
 BE INSTALLED WITH THE BOTTOM EDGE OF THE REFLECTING
 SURFACE 40 INCHES (1015 MM) MAXIMUM ABOVE THE FINISH
 FLOOR OR GROUND.
 4) THE TOILET PAPER DISPENSER = SEE FBC ACCESSIBILITY
 FIGURE 604.7
 5) PLEASE SHOW THE BUILDING EXIT DOOR AND THE RESTROOM
 DOOR MANUVERING CLEARANCE TO COMPLY WITH FBC
 ACCESSIBILITY 404.2.4 SEE FIGURE 404.2.4.1
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2020-10-29 Cont ID  
Sent By rmcphers Date 2020-10-29 Time 14:43 Rev Time 0.00
Received By rmcphers Date 2020-10-29 Time 14:28 Sent To  
Notes
2020-10-29 14:43:21ADD RESTROOM
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1
 AMENDMENTS
  
 2ND REVIEW
  
 CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107
 1) PLEASE SHOW THE BUILDING USE (OCCUPANCY
 CLASSIFICATION PER FBC CHAPTER 3.
 2) PLEASE SHOW THE WALL AND FLOOR FINISHES TO COMPLY
 WITH FBC 1210.2 (DRYWALL IS NOT CONSIDERED A HARD
 SURFACE)
 3) PLEASE SHOW THE BOTTOM OF THE MIRROR REFLECTION TO
 THE FINISHED FLOOR TO COMPLY WITH FBC ACCESSIBILITY
 603.3 MIRRORS.
 MIRRORS LOCATED ABOVE LAVATORIES OR COUNTERTOPS SHALL
 BE INSTALLED WITH THE BOTTOM EDGE OF THE REFLECTING
 SURFACE 40 INCHES (1015 MM) MAXIMUM ABOVE THE FINISH
 FLOOR OR GROUND.
 4) THE 36" GRAB BAR ON THE BACK WALL OF THE WATER
 CLOSET = 24" AND 12" NEED TO BE SHOWN FROM THE CENTER
 LINE OF THE WATER CLOSET SEE FBC ACCESSIBILITY FIGURE
 604.5.2
 5) THE TOILET PAPER DISPENSER = THE 7" TO 9" NEEDS TO
 BE SHOWN TO THE CENTER OF THE DISPENSER SEE FBC
 ACCESSIBILITY FIGURE 604.7
 6) PLEASE SHOW THE BUILDING EXIT DOOR AND THE RESTROOM
 DOOR MANUVERING CLEARANCE TO COMPLY WITH FBC
 ACCESSIBILITY 404.2.4 SEE FIGURE 404.2.4.1
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-09-28 Cont ID  
Sent By rmcphers Date 2020-09-28 Time 14:34 Rev Time 0.00
Received By rmcphers Date 2020-09-28 Time 13:56 Sent To  
Notes
2020-09-28 14:34:25ADD RESTROOM
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1
 AMENDMENTS
  
 CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107
 1) PLEASE SHOW THE BUILDING USE (OCCUPANCY
 CLASSIFICATION PER FBC CHAPTER 3.
 2) PLEASE SHOW THE WALL AND FLOOR FINISHES TO COMPLY
 WITH FBC 1210.2 (DRYWALL IS NOT CONSIDERED A HARD
 SURFACE)
 3) DOOR CANNOT SWING INTO THE PATH OF EGRESS FBC
 1005.7.1 DOORS.
 DOORS, WHEN FULLY OPENED, SHALL NOT REDUCE THE REQUIRED
 WIDTH BY MORE THAN 7 INCHES (178 MM). DOORS IN ANY
 POSITION SHALL NOT REDUCE THE REQUIRED WIDTH BY MORE
 THAN ONE-HALF.
 4) PLEASE SHOW THE BOTTOM OF THE MIRROR REFLECTION TO
 THE FINISHED FLOOR TO COMPLY WITH FBC ACCESSIBILITY
 603.3 MIRRORS.
 MIRRORS LOCATED ABOVE LAVATORIES OR COUNTERTOPS SHALL
 BE INSTALLED WITH THE BOTTOM EDGE OF THE REFLECTING
 SURFACE 40 INCHES (1015 MM) MAXIMUM ABOVE THE FINISH
 FLOOR OR GROUND.
 5) PLEASE SHOW THE BUILDING EXIT DOOR MANUVERING
 CLEARANCE TO COMPLY WITH FBC ACCESSIBILITY 404.2.4
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2020-12-16 Cont ID  
Sent By jleahy Date 2020-12-16 Time 09:20 Rev Time 0.00
Received By jleahy Date 2020-12-16 Time 09:20 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2020-11-02 Cont ID  
Sent By jleahy Date 2020-11-02 Time 11:25 Rev Time 0.00
Received By jleahy Date 2020-11-02 Time 11:23 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2020-09-23 Cont ID  
Sent By jleahy Date 2020-09-23 Time 15:07 Rev Time 0.00
Received By jleahy Date 2020-09-23 Time 15:04 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2020-12-10 Cont ID  
Sent By pleduc Date 2020-12-10 Time   Rev Time 0.00
Received By pleduc Date 2020-12-10 Time 16:05 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2020-10-22 Cont ID  
Sent By pleduc Date 2020-10-22 Time   Rev Time 0.00
Received By pleduc Date 2020-10-22 Time 13:43 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2020-09-15 Cont ID  
Sent By pleduc Date 2020-09-15 Time   Rev Time 0.00
Received By pleduc Date 2020-09-15 Time 10:43 Sent To  
Notes
2020-09-15 10:51:57THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC,
 FIRE MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 PLEASE CONSIDER THE FOLLOWING AS PROVISO:
  
 THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED
 AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE
 PROVISO COMMENTS WILL RESULT IN A FAILED FIRE
 INSPECTION.
  
  
 1) THE BATHROOM DOOR IS INDICATED AS OPENING INTO THE
 PATH OF EGRESS. THE BATHROOM DOOR SHALL NOT BLOCK THE
 EXTERIOR EXIT DOOR.
  
 DOES THAT EXTERIOR DOOR HAVE AN EXIT SIGN OVER IT
 AND/OR IS IT A REQUIRED EXIT DOOR? SOME BUSINESSES CAN
 HAVE A SINGLE EXIT (FRONT DOOR) IF IT MEETS THE CODE
 REQUIRMENTS FOR A SINGLE EXIT.
  
 PER NFPA 101 CHAPTER 7, MEANS OF EGRESS
  
 7.2.1.4.3 DOOR LEAF ENCROACHMENT
 7.2.1.4.3.1 DURING ITS SWING, ANY DOOR LEAF IN A MEANS
 OF EGRESS SHALL
 LEAVE NOT LESS THAN ONE-HALF OF THE REQUIRED WIDTH OF
 AN AISLE, A CORRIDOR, A
 PASSAGEWAY, OR A LANDING UNOBSTRUCTED AND SHALL NOT
 PROJECT NOT MORE THAN
 7 IN. INTO THE REQUIRED WIDTH OF AN AISLE, A CORRIDOR,
 A PASSAGE WAY, OR A
 LANDING, WHEN FULLY OPEN, UNLESS BOTH OF THE FOLLOWING
 CONDITIONS ARE MET:
 (1) THE DOOR OPENING PROVIDES ACCESS TO A STAIR IN AN
 EXISTING BUILDING.
 (2) THE DOOR OPENING MEETS THE REQUIREMENTS THAT LIMITS
 PROJECTION TO
 NOT MORE THAN 7 IN. INTO THE REQUIRED WIDTH OF THE
 STAIR LANDING
 WHEN THE DOOR LEAF IS FULLY OPEN.
  
 NFPA 101 CH 39 EXISTING BUSINESS
  
 39.2.4.2 EXIT ACCESS, AS REQUIRED BY 39.2.4.1(3), SHALL
 BE PERMITTED
 TO INCLUDE A SINGLE EXIT ACCESS PATH FOR THE DISTANCES
 PERMITTED AS
 COMMON PATHS OF TRAVEL BY 39.2.5.3.
  
 39.2.4.3 A SINGLE EXIT SHALL BE PERMITTED FOR A ROOM OR
 AREA WITH A
 TOTAL OCCUPANT LOAD OF LESS THAN 100 PERSONS, PROVIDED
 THAT ALL OF
 THE FOLLOWING CRITERIA ARE MET:
 (1) THE EXIT SHALL DISCHARGE DIRECTLY TO THE OUTSIDE AT
 THE LEVEL OF
 EXIT DISCHARGE FOR THE BUILDING.
 (2) THE TOTAL DISTANCE OF TRAVEL FROM ANY POINT,
 INCLUDING TRAVEL
 WITHIN THE EXIT, SHALL NOT EXCEED 100 FT (30 M).
 (3) THE TOTAL DISTANCE OF TRAVEL SPECIFIED IN
 39.2.4.3(2) SHALL BE
 ON THE SAME STORY, OR, IF TRAVERSING OF STAIRS IS
 NECESSARY, SUCH
 STAIRS SHALL NOT EXCEED 15 FT (4570 MM) IN HEIGHT, AND
 BOTH OF
 THE FOLLOWING ALSO SHALL APPLY:
 (A) INTERIOR STAIRS SHALL BE PROVIDED WITH COMPLETE
 ENCLOSURES TO SEPARATE THEM FROM ANY OTHER PART OF THE
 BUILDING, WITH NO DOOR OPENINGS THEREIN.
 (B) A SINGLE OUTSIDE STAIR IN ACCORDANCE WITH 7.2.2
 SHALL BE
 PERMITTED TO SERVE ALL STORIES PERMITTED WITHIN THE 15
 FT
 (4570 MM) VERTICAL TRAVEL LIMITATION.
  
 IF THAT EXIT DOOR IS A REQUIRED EXIT THEN THE BATHROOM
 DOOR SHALL NOT OPEN OUT TO BLOCK THE EXIT. THE DOOR
 SHALL SWING INTO THE BATHROOM.
  
 IF THERE IS AN EXIT SIGN OVER THE DOOR BUT IS NOT A
 REQUIRED EXIT, REMOVE THE EXIT SIGN AND THE DOOR CAN
 REMAIN SWINGING OUT.
  
 THE FIRE INSPECTOR WITH VERIFY ON INSPECTION.
  
 PLEASE ENSURE COMPLIANCE.
  
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  
  

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2021-01-13 Cont ID  
Sent By rmcphers Date 2021-01-13 Time 09:13 Rev Time 0.00
Received By rmcphers Date 2021-01-13 Time 08:30 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2021-01-07 Cont ID  
Sent By lcrespo Date 2021-01-07 Time 08:54 Rev Time 0.00
Received By lcrespo Date 2020-12-09 Time 07:35 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-11-03 Cont ID  
Sent By tklarge Date 2020-11-03 Time 09:42 Rev Time 0.00
Received By tklarge Date 2020-10-21 Time 07:28 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-09-28 Cont ID  
Sent By rmcphers Date 2020-09-28 Time 14:36 Rev Time 0.00
Received By rmcphers Date 2020-09-11 Time 11:04 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 4 Status P Date 2021-01-13 Cont ID  
Sent By lcrespo Date 2021-01-13 Time 08:11 Rev Time 0.00
Received By lcrespo Date 2021-01-13 Time 08:11 Sent To  
Notes
2021-01-13 08:12:1301/13/21 REVIEWED FOR CODE COMPLIANCE (PLUMBING)
  
 BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE
 COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN
 PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES
 FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL,
 STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT
 THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK
 OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM
 REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES
 / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO
 AVOID VOIDING OF THE PERMIT.
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  

Review Stop P PLUMBING
Rev No 3 Status F Date 2021-01-07 Cont ID  
Sent By lcrespo Date 2021-01-07 Time 08:50 Rev Time 0.00
Received By lcrespo Date 2020-12-29 Time 16:11 Sent To  
Notes
2021-01-07 08:55:0801/07/20 3RD PLUMBING REVIEW**DENIED** WITH COMMENTS
  
 NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS
 TIME, AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE
 GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS.
  
 THIS IS THE THIRD PLAN REVIEW THAT HAS NOT PASSED.
 PLEASE GET WITH THE PLAN REVIEWER AND MAKE AN
 APPOINTMENT TO COME INTO THE BUILDING DEPARTMENT TO
 EXPLAIN WHAT IS NEEDED.
  
 1. PLEASE SHOW THE BUILDING USE (OCCUPANCY
 CLASSIFICATION PER FBC CHAPTER 3.
  
 2. PLEASE SHOW THE WALL AND FLOOR FINISHES TO COMPLY
 WITH FBC 1210.2.2. EPOXY PAINT ON DRYWALL DOES NOT MEET
 THE INTENT OF THE CODE.
  
 3. PLEASE SHOW THE BOTTOM OF THE MIRROR'S REFLECTIVE
 SURFACE TO THE FINISHED FLOOR TO COMPLY WITH FBC
 ACCESSIBILITY 603.3 MIRRORS, NOT THE MIRROR'S FRAME.
  
 4. THE 24" AND 12" ON THE GRAB BAR BEHIND THE TOILET
 NEED TO BE SHOWN FROM THE CENTERLINE OF THE WATER
 CLOSET, NOT TO THE EDGE OF THE TOILET SEE FBC
 ACCESSIBILITY FIGURE 604.5.2.
  
 5. TOILET PAPER DISPENSER - THE 7" TO 9" NEEDS TO BE
 SHOWN TO THE CENTER OF THE DISPENSER, REMOVE THE 9??
 AND PUT 15? TO TOP OF DISPENSER SEE FBC ACCESSIBILITY
 FIGURE 604.7.
  
 6. PLEASE SHOW THE REQUIRED CLEAR FLOOR SPACE AND
 DIMENSIONS FOR THE TOILET AND LAVATORY IN THE TOILET
 ROOM PER FBC-ACCESS. SECS. 604.3.1 AND FIGURE 604.3.1
 AND 606..2 AND SECS.305 & 306.
  
 WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION &
 REMOVE ANY VOIDED SHEETS & REPLACE ANY NECESSARY PAGES.
 A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 HTTPS://CODES.ICCSAFE.ORG/CODES/FLORIDA
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  

Review Stop P PLUMBING
Rev No 2 Status F Date 2020-11-03 Cont ID  
Sent By tklarge Date 2020-11-03 Time 09:42 Rev Time 0.00
Received By tklarge Date 2020-11-03 Time 09:04 Sent To  
Notes
2020-11-03 09:42:34 
 1) PLEASE SHOW THE BUILDING USE (OCCUPANCY
 CLASSIFICATION PER FBC CHAPTER 3.
 2) PLEASE SHOW THE WALL AND FLOOR FINISHES TO COMPLY
 WITH FBC 1210.2.2. EPOXY PAINT ON DRYWALL DOES NOT MEET
 THE INTENT OF THE CODE.
 3) PLEASE SHOW THE BOTTOM OF THE MIRROR'S REFLECTIVE
 SURFACE TO THE FINISHED FLOOR TO COMPLY WITH FBC
 ACCESSIBILITY 603.3 MIRRORS.
 MIRRORS LOCATED ABOVE LAVATORIES OR COUNTERTOPS SHALL
 BE INSTALLED WITH THE BOTTOM EDGE OF THE REFLECTING
 SURFACE 40 INCHES (1015 MM) MAXIMUM ABOVE THE FINISH
 FLOOR OR GROUND.
 4) THE 24" AND 12" ON THE GRAB BAR BEHIND THE TOILET
 NEED TO BE SHOWN FROM THE CENTER LINE OF THE WATER
 CLOSET SEE FBC ACCESSIBILITY FIGURE 604.5.2
 5) TOILET PAPER DISPENSER - THE 7" TO 9" NEEDS TO BE
 SHOWN TO THE CENTER OF THE DISPENSER SEE FBC
 ACCESSIBILITY FIGURE 604.7
 6) THE LOCATION OF THE GRAB BAR ADJACENT TO THE TOILET
 SHALL COMPLY WITH FBC-ACCESS. SEC.604.5.1 & FIGURE
 604.5.1.
 7) THE SIDE ELEVATION STILL SHOWS THE GRAB BAR MEASURED
 TO THE CENTERLINE OF THE BAR. THE BAR SHALL BEE MEASURE
 TO THE TOP OF THE GRIPPING SURFACE. FBS- ACCESS.
 609..4.
 8) SHOW THE REQUIRED CLEAR FLOOR SPACE DIMENSIONS FOR
 THE TOILET AND LAVATORY IN THE TOILET ROOM PER
 FBC-ACCESS. SECS. 604.3.1 AND FIGURE 604.3.1 AND 606..2
 AND SECS.305 & 306.
  
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 CITY OF WEST PALM BEACH
 561-805-6692; [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2020-09-16 Cont ID  
Sent By abelisle Date 2020-09-16 Time 19:09 Rev Time 0.00
Received By abelisle Date 2020-09-16 Time 18:14 Sent To  
Notes
2020-09-16 18:14:331ST REVIEW FBC-2017 PLUMBING
 PERMIT-20081406
 9/16/2020
  
 CODES IN EFFECT:
  
 FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017
 FBC ACC- FLORIDA ACCESSIBILITY CODE SIXTH ADDITION 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1. A SUB PLUMBING PERMIT IS REQUIRED BY A LICENSED
 CONTRACTOR FOR THE SCOPE OF WORK PER THE WPB AMENDMENTS
 TO THE FBC SEC. 105.1.
  
 2. SUBMIT A SLAB REPAIR DETAIL FOR REVIEW. SHOW THE
 WIDTH OF THE REPAIR, THE MINIMUM THICKNESS OF THE
 CONCRETE TO BE REPLACED, AND THE PSI OF THE CONCRETE.
 SHOW THE SIZE AND LENGTH OF THE DOWELS, THE MINIMUM
 EMBEDMENT DEPTH INTO THE EXISTING SLAB, AND THE SPACING
 OF THE DOWELS ON THE CENTER. THE REPAIR SHALL ALSO
 INCLUDE TERMITE TREATMENT OF THE SOIL AND THE REQUIRED
 VAPOR BARRIER OVER THE SOIL. A COPY OF THE TERMITE
 CERTIFICATE SHALL BE ONSITE FOR A FINAL INSPECTION.
  
 3. PLEASE PROVIDE WHAT TYPE OF OCCUPANCY THIS INTERIOR
 BUILD-OUT WILL BE AND THE OCCUPANCY LOAD WPB AMENDMENTS
 TO THE FBC SEC. 107.2.1 INFORMATION ON CONSTRUCTION
 DOCUMENTS.
  
 4. THERE IS MEASUREMENT DISCREPANCIES ON THE GRAB BAR
 LOCATIONS AND THE TOILET PAPER LOCATION PLEASE REFER TO
 FBC ACC 603, FBC ACC 604.5.1 FBC ACC 604.7
  
 5. DOOR CANNOT SWING OUT AND OBSTRUCT LIFESAFETY TRAVEL
 PATH TO THE EXIT REAR DOOR FBC ACC 603.2.3
  
 6. THE PLUMBING PLAN SHALL BEAR THE TITLE BLOCK AND
 ELECTRONIC SEAL AND SIGNATURE OF THE FL. LICENSED
 ARCHITECT OR ENGINEER WHO PREPARED THE DRAWING- SECTION
 107.2.1 WPB, FL. STATUTES 471.025 & 481.221, AND
 SECTIONS 61G15-23.005 & 61G1-16.005 FAC.
 CONTRACTOR- DRAWN PLANS SHALL BEAR THE TITLE BLOCK,
 LICENSE NUMBER, AND SIGNATURE OF THE FL. LICENSED
 CONTRACTOR OR QUALIFIER WHO PREPARED THE DRAWING-
 SECTION 107.2.1 WPB.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 ATELYO BELISLE
 PLUMBING INSPECTOR /
 PLUMBING PLAN REVIEW
 AVAILABLE FROM 1:00 PM TO 4:00 PM
 [email protected]
 561-805-6695
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status N Date 2020-12-16 Cont ID  
Sent By rmcphers Date 2020-12-16 Time 16:01 Rev Time 0.00
Received By rmcphers Date 2020-12-16 Time 16:01 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status N Date 2020-10-29 Cont ID  
Sent By rmcphers Date 2020-10-29 Time 14:43 Rev Time 0.00
Received By rmcphers Date 2020-10-29 Time 14:43 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status N Date 2020-09-28 Cont ID  
Sent By rmcphers Date 2020-09-28 Time 14:36 Rev Time 0.00
Received By rmcphers Date 2020-09-28 Time 14:36 Sent To  
Notes
***NONE***