Plan Review Details - Permit 20081404
Plan Review Stops For Permit 20081404
Review Stop AD ADDRESSING
Rev No 2 Status P Date 2020-09-02 Cont ID  
Sent By cpuell Date 2020-09-02 Time 13:09 Rev Time 0.00
Received By cpuell Date 2020-09-02 Time 13:09 Sent To  
Notes
2020-09-02 13:09:54NEW ADDRESS CREATED 718 20TH ST

Review Stop AD ADDRESSING
Rev No 1 Status F Date 2020-08-31 Cont ID  
Sent By cpuell Date 2020-08-31 Time 12:03 Rev Time 0.00
Received By cpuell Date 2020-08-31 Time 12:03 Sent To  
Notes
2020-08-31 12:04:00PLEASE CONTACT [email protected] TO ESTABLISH ADDRESS FOR
 THIS PREVIOUSLY UNADDRESSED PARCEL

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2020-10-21 Cont ID  
Sent By rmcphers Date 2020-10-21 Time 15:09 Rev Time 0.00
Received By rmcphers Date 2020-10-21 Time 15:09 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-09-24 Cont ID  
Sent By rmcphers Date 2020-09-24 Time 09:09 Rev Time 0.00
Received By rmcphers Date 2020-09-24 Time 07:57 Sent To  
Notes
2020-09-24 09:18:08NEW SFR
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1
 AMENDMENTS
  
 CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107
 1) PLEASE PROVIDE A SIGNED AND SEALED SOIL REPORT AS
 NOTED ON THE FOUNDATION PLAN.
 2) BUILDING VALUE APPEARS TO BE LOW - PLEASE REVISE THE
 BUILDING PERMIT APPLICATION IF NEEDED. COST FBC WPB
 AMENDMENTS ? FOR PERMITTING PURPOSES THE VALUE OF ALL
 LABOR AND MATERIALS REQUIRED TO COMPLETE THE PROJECT
 ARE REQUIRED TO BE INCLUDED IN THE COST. FBC 109.3
 BUILDING PERMIT VALUATION. FOR PERMITTING PURPOSES,
 VALUATION OF BUILDINGS AND SYSTEMS SHALL BE TOTAL
 REPLACEMENT VALUE TO INCLUDE STRUCTURAL, ELECTRIC,
 PLUMBING, MECHANICAL, INTERIOR FINISH, RELATIVE SITE
 WORK, ARCHITECTURAL AND DESIGN FEES, MARKETING COST,
 OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE.
 VALUATION REFERENCES MAY INCLUDE THE LATEST PUBLISHED
 DATA OF NATIONAL CONSTRUCTION COST ANALYSIS SERVICES
 (MARSHALL ? SWIFT, MEANS, ETC.) AS PUBLISHED BY
 INTERNATIONAL CODE CONGRESS. FINAL BUILDING PERMIT
 VALUATION SHALL BE SET BY THE BUILDING OFFICIAL.
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2020-09-15 Cont ID  
Sent By fgiaquin Date 2020-09-15 Time 21:58 Rev Time 0.00
Received By fgiaquin Date 2020-09-15 Time 21:11 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-10-21 Cont ID  
Sent By rmcphers Date 2020-10-21 Time 15:12 Rev Time 0.00
Received By rmcphers Date 2020-10-14 Time 16:07 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-09-24 Cont ID  
Sent By rmcphers Date 2020-09-24 Time 09:21 Rev Time 0.00
Received By rmcphers Date 2020-09-02 Time 07:12 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 3 Status P Date 2020-10-23 Cont ID  
Sent By lmarchan Date 2020-10-23 Time 11:01 Rev Time 0.00
Received By lmarchan Date 2020-10-23 Time 09:35 Sent To  
Notes
2020-10-23 09:36:27RECEIPT - MU-2020-40777 - $11,913.65 - PAID

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status F Date 2020-10-21 Cont ID  
Sent By rmcphers Date 2020-10-21 Time 15:10 Rev Time 0.00
Received By rmcphers Date 2020-10-21 Time 15:10 Sent To  
Notes
2020-10-21 15:11:53PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF
  
 UPON APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE
 RECEIPT TO YOUR PROJECT OR EMAIL IT TO
 [email protected] .
  

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2020-09-24 Cont ID  
Sent By rmcphers Date 2020-09-24 Time 09:18 Rev Time 0.00
Received By rmcphers Date 2020-09-24 Time 09:18 Sent To  
Notes
2020-09-24 09:20:46PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF
  
 UPON APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE
 RECEIPT TO YOUR PROJECT OR EMAIL IT TO
 [email protected] .
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2020-09-14 Cont ID  
Sent By medwards Date 2020-09-14 Time 11:38 Rev Time 0.00
Received By medwards Date 2020-09-14 Time 10:45 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2020-10-15 Cont ID  
Sent By ccole Date 2020-10-15 Time 07:41 Rev Time 0.00
Received By ccole Date 2020-10-15 Time 07:09 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2020-09-14 Cont ID  
Sent By ccole Date 2020-09-14 Time 07:22 Rev Time 0.00
Received By ccole Date 2020-09-14 Time 06:56 Sent To  
Notes
2020-09-14 07:24:391ST REVIEW FBC-2017 RES. PLUMBING
 PERMIT- 20081404
 9/14/2020
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH
 EDITION 2017
 FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET P1: SUBMIT MANUFACTURER'S SPECIFICATIONS FOR
 THE WATER HEATER AND PROVIDE AN EQUIPMENT SCHEDULE ON
 THE PLAN INDICATING MAKE, MODEL, GALLON SIZE, AND
 EFFICIENCY RATING- SECTION C404.2 FBC EC.
  
 2) P1, WATER RISER: SHOW THE WATER LINE CONNECTIONS TO
 THE ISLAND SINK, DISHWASHER, REFRIGERATOR ICE MAKER,
 AND THE HOSE BIBB- P2903.7 FBC RES.
  
 3) P1, WATER RISER: SHOW THE LOCATIONS OF REQUIRED
 WATER HAMMER ARRESTORS FOR SUPPLY LINES TO THE
 DISHWASHER, WASHING MACHINE AND REFRIGERATOR ICE MAKER-
 SECTION P2903.5 FBC RES.
  
 4) P1, WATER RISER: SHOW THE REQUIRED BACKFLOW
 PREVENTER FOR THE SUPPLY LINE TO THE ICE MAKER-
 SECTION- P2902.1 FBC RES.
  
 5) P1: PLEASE NOTE THAT A FL. LICENSED PLUMBING
 CONTRACTOR SHALL OBTAIN A SEPARATE PERMIT FOR
 INSTALLATION OF THE WATER SERVICE BACKFLOW PREVENTER IN
 ACCORDANCE WITH SECTION 105.1 WPB AND SEC, 90-33 WPB
 CODE OF ORDINANCES. THE DEVICE SHALL BE TESTED AND
 CERTIFIED BY THE WPB UTILITIES DEPARTMENT PRIOR TO
 FINAL INSPECTION BY THE BUILDING DEPARTMENT. PLEASE
 CONTACT THE WPB UTILITIES CENTRAL OPERATIONS DEPT.AT
 561-822-2210 FOR FURTHER INFORMATION.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2020-09-24 Cont ID  
Sent By rmcphers Date 2020-09-24 Time 09:20 Rev Time 0.00
Received By rmcphers Date 2020-09-24 Time 09:20 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2020-10-15 Cont ID  
Sent By medwards Date 2020-10-15 Time 16:15 Rev Time 0.00
Received By medwards Date 2020-10-15 Time 16:15 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2020-09-14 Cont ID  
Sent By medwards Date 2020-09-14 Time 11:38 Rev Time 0.00
Received By medwards Date 2020-09-14 Time 11:38 Sent To  
Notes
2020-09-14 11:38:351ST REVIEW FBC-2017 MECHANICAL
 PERMIT-20081404
  
 CODES IN EFFECT:
  
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH
 EDITION 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) DESIGNER OF THE ENERGY GAUGE DOCUMENT NEEDS TO FILL
 IN THE ?PREPARED BY? AREA OF THE DOCUMENT. ALSO ON PAGE
 2 OF THIS DOCUMENT PLEASE ADD THE PHYSICAL ADDRESS OF
 THIS NEW SFD. FBC FS 107.2.1
  
 2) PER THE WPB AMENDMENTS TO THE FBC, EACH SHEET OF
 PLAN IS REQUIRED TO BE SIGNED AND SEALED BY THE PERSON
 RESPONSIBLE FOR THE DESIGN. A DIGITAL PLAN REQUIRES A
 DIGITAL SIGNATURE WITH THE PROPER THIRD PARTY
 VERIFICATION. PROVIDE CORRECTION. ALTERNATIVELY, A
 SIGNED/SEALED PAPER SET MAY BE SUPPLIED TO THE BUILDING
 DEPARTMENT WHEN ALL TRADES ARE APPROVED. WPB FBC 107.1;
 FS 471/481
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD
 SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER
 SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN
 THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS
 PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS
 PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR
 UPDATED.
  
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop Z ZONING
Rev No 1 Status P Date 2020-09-15 Cont ID  
Sent By rthermid Date 2020-09-15 Time   Rev Time  
Received By rthermid Date 2020-09-15 Time   Sent To I
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved