Plan Review Details - Permit 20080987
Plan Review Stops For Permit 20080987
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2020-11-17 Cont ID  
Sent By cthroop Date 2020-11-17 Time 09:46 Rev Time 0.00
Received By cthroop Date 2020-11-17 Time 08:01 Sent To  
Notes
2020-11-17 09:50:40PROVISO: PROVIDE ICC-ES REPORT FOR SPRAY FOAM
 INSULATION TO CITY INSPECTOR. CT
  
 NOTICE: PROPERTY IS LOCATED IN A SFHA. FLOOD ZONE AE
 W/BFE'S OF 6.0 ' AND 7.0' NAVD. PROJECT DOES NOT
 QUALIFY AS A S/I PER FEMA.
 IMPROVEMENT VALUE PER PAPA - $1,159,654. VALUE OF
 PERMIT W/5 YR TAIL - $126,325. CT

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2021-04-23 Cont ID  
Sent By equinone Date 2021-04-23 Time 10:30 Rev Time 0.00
Received By equinone Date 2021-04-23 Time 10:12 Sent To  
Notes
2021-04-23 10:31:41CODES IN EFFECT
 CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 FAC = FLORIDA ADMINISTRATIVE CODE
  
 ELECTRICAL REVIEW STATUS: APPROVED, SEE COMMENTS BELOW.
  
 1) SPACING OF RECEPTACLES NEEDS TO COMPLY WITH NEC
 210.52(A). FLOOR RECEPTACLES NEED TO BE LOCATED WITHIN
 18 INCHES OF THE WALL TO COUNT FOR THE REQUIRED NUMBER
 OF RECEPTACLES. NEC 210.52(A)
  
 CORRECTED
  
 2) EXISTING RISER DIAGRAM SHOWS #2/0 FEEDERS FROM 200
 AMPS BREAKERS TO ELECTRICAL PANELS. SIZE #2/0 IS ONLY
 GOOD FOR 175 AMPS AND BECAUSE THIS AMPACITY MATCHES A
 175 AMPS STANDARD SIZE BREAKER YOU ARE NOT ALLOWED TO
 JUMP TO THE NEXT STANDARD SIZE AND A #3/0 CU IS
 REQUIRED. PLEASE DOUBLE CHECK WHAT SIZE IS CURRENTLY
 EXISTING TO MAKE SURE INSTALLATION COMPLIES WITH NEC
 240.4 (B)(2).
  
 RISER SHOWS 2 SETS OF #2/0
  
  
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  
  
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2021-03-08 Cont ID  
Sent By equinone Date 2020-11-17 Time 10:59 Rev Time 0.00
Received By equinone Date 2020-11-17 Time 10:59 Sent To  
Notes
2021-03-08 11:29:32CODES IN EFFECT
 CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 FAC = FLORIDA ADMINISTRATIVE CODE
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1) SPACING OF RECEPTACLES NEEDS TO COMPLY WITH NEC
 210.52(A). FLOOR RECEPTACLES NEED TO BE LOCATED WITHIN
 18 INCHES OF THE WALL TO COUNT FOR THE REQUIRED NUMBER
 OF RECEPTACLES. NEC 210.52(A)
 2) EXISTING RISER DIAGRAM SHOWS #2/0 FEEDERS FROM 200
 AMPS BREAKERS TO ELECTRICAL PANELS. SIZE #2/0 IS ONLY
 GOOD FOR 175 AMPS AND BECAUSE THIS AMPACITY MATCHES A
 175 AMPS STANDARD SIZE BREAKER YOU ARE NOT ALLOWED TO
 JUMP TO THE NEXT STANDARD SIZE AND A #3/0 CU IS
 REQUIRED. PLEASE DOUBLE CHECK WHAT SIZE IS CURRENTLY
 EXISTING TO MAKE SURE INSTALLATION COMPLIES WITH NEC
 240.4 (B)(2).
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD
 SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER
 SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN
 THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS
 PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS
 PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR
 UPDATED.
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
  
 IF THE RESUBMITTAL IS NOT PREPARED BY A DESIGN
 PROFESSIONAL (ARCHITECT OR ENGINEER), AND THE PAGES ARE
 11X17 OR SMALLER, YOU MAY RESUBMIT, ALONG WITH A
 COMPLETED RESUBMITTAL FORM, VIA EMAIL TO
 [email protected]. THE EMAIL SHOULD INCLUDE THE PERMIT
 NUMBER AND "RESUBMITTAL" IN THE SUBJECT LINE. THE
 RESUBMITTAL FORM CAN BE FOUND AT THIS WEBSITE:
  
 HTTPS://WWW.WPB.ORG/GOVERNMENT/DEVELOPMENT-SERVICES/FOR
 MS
  
 ENRIQUE QUINONEZ P.E.
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-05-14 Cont ID  
Sent By rmcphers Date 2021-05-14 Time 13:46 Rev Time 0.00
Received By rmcphers Date 2021-04-13 Time 09:53 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-12-03 Cont ID  
Sent By lmarchan Date 2020-12-03 Time 07:59 Rev Time 0.00
Received By lmarchan Date 2020-11-02 Time 17:23 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2021-05-29 Cont ID  
Sent By lmarchan Date 2021-05-29 Time 08:32 Rev Time 0.00
Received By lmarchan Date 2021-05-25 Time 13:44 Sent To  
Notes
2021-05-29 08:32:32RECEIPT MU-2021-26367 - $0.00 NO FEES DUE
2021-05-25 13:44:295/25/21 EMAILED IMPACT OFFICE FOR REVIEW. LEM

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2021-05-14 Cont ID  
Sent By rmcphers Date 2021-05-14 Time 13:44 Rev Time 0.00
Received By rmcphers Date 2021-05-14 Time 13:44 Sent To  
Notes
2021-05-14 13:44:532ND FLOOR AC SPACE ADDED - -
 PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF
  
 UPON APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE
 RECEIPT TO YOUR PROJECT OR EMAIL IT TO
 [email protected] .
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2021-04-22 Cont ID  
Sent By medwards Date 2021-04-22 Time 08:04 Rev Time 0.00
Received By medwards Date 2021-04-22 Time 08:01 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2020-11-04 Cont ID  
Sent By medwards Date 2020-11-04 Time 15:40 Rev Time 0.00
Received By medwards Date 2020-11-04 Time 15:02 Sent To  
Notes
2020-11-04 15:40:561ST REVIEW FBC-2017 MECHANICAL
 PERMIT-20080987
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH
 EDITION 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) PLEASE SHOW ON THE DRAWING HOW THE CONDENSATION WILL
 BE REMOVED. FBC RES M1411.3
  
 2) PLEASE SHOW HOW THE CONDENSING UNIT WILL BE ANCHORED
 DOWN. FBC RES M1307.2
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD
 SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER
 SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN
 THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS
 PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS
 PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR
 UPDATED.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 1 Status N Date 2021-05-15 Cont ID  
Sent By cthroop Date 2021-05-15 Time 11:25 Rev Time 0.00
Received By cthroop Date 2021-05-15 Time 11:25 Sent To  
Notes
2021-05-15 11:26:47NOTICE: PROPERTY IS LOCATED IN A SFHA. FLOOD ZONE AE
 W/BFE'S OF 6.0 ' AND 7.0' NAVD. PROJECT DOES NOT
 QUALIFY AS A S/I PER FEMA 50% RULE.
 IMPROVEMENT VALUE PER PAPA - $1,159,654. VALUE OF
 PERMIT W/5 YR TAIL - $126,325. CT

Review Stop P PLUMBING
Rev No 1 Status N Date 2020-11-04 Cont ID  
Sent By lcrespo Date 2020-11-04 Time 09:35 Rev Time 0.00
Received By lcrespo Date 2020-11-04 Time 09:35 Sent To  
Notes
2020-11-04 09:36:31PER PLANS THERE IS NO PLUMBING ON THE SCOPE OF WORK.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status N Date 2020-11-17 Cont ID  
Sent By cthroop Date 2020-11-17 Time 09:46 Rev Time 0.00
Received By cthroop Date 2020-11-17 Time 08:01 Sent To  
Notes
2020-11-17 09:46:33PROVISO: SEPERATE ROOFING PERMIT REQUIRED. CT

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2021-04-22 Cont ID  
Sent By medwards Date 2021-04-22 Time 08:04 Rev Time 0.00
Received By medwards Date 2021-04-22 Time 08:04 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2020-11-04 Cont ID  
Sent By medwards Date 2020-11-04 Time 15:46 Rev Time 0.00
Received By medwards Date 2020-11-04 Time 15:46 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2021-05-11 Cont ID  
Sent By rthermid Date 2021-05-11 Time   Rev Time 0.00
Received By rthermid Date 2021-05-11 Time   Sent To I
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2020-11-05 Cont ID  
Sent By rthermid Date 2020-11-05 Time   Rev Time  
Received By rthermid Date 2020-11-05 Time   Sent To I
Notes
2020-11-05 13:24:23ZONING PLAN REVIEW
 ________________________________________
  
 DATE OF REVIEW: 11/5/2020
 ________________________________________
  
 REVIEW STATUS: FAILED
 ________________________________________
  
 PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN
 REVIEW COMMENTS:
  
 1. PLEASE PROVIDE A SURVEY OF THE PROPERTY INDICATING
 THE SETBACKS OF THE PROPOSED WORK TO ALL PROPERTY
 LINES.
 ________________________________________
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 IF YOU SUBMITTED A PAPER APPLICATION, AND YOU WOULD
 LIKE TO RESUBMIT ELECTRONICALY, EMAIL
 [email protected] AND REQUEST TO HAVE YOUR
 PROJECT CONVERTED TO PROJECTDOX. YOU WILL RECEIVE LOGIN
 INFORMATION AND A LINK TO UPLOAD YOUR RESUBMITTAL.
 PLEASE BE SURE TO ?COMPLETE THE UPLOAD TASK? WHEN YOU
 ARE FINISHED UPLOADING.
  
 ________________________________________
  
 QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING:
  
 RAFAELA THERMIDOR, ASSOCIATE PLANNER
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION
 401 CLEMATIS STREET - P.O. BOX 3147
 WEST PALM BEACH, FLORIDA 33402
  
 TTY: 800.955.8771
 E: [email protected]
 W: WPB.ORG
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved