Plan Review Stops For Permit 20080956 |
Review Stop |
E |
ELECTRICAL |
Rev No |
5 |
Status |
P |
Date |
2021-04-12 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2021-04-12 |
Time |
10:03 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2021-04-12 |
Time |
10:03 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
P |
Date |
2021-04-05 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2021-04-05 |
Time |
13:00 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2021-04-05 |
Time |
13:00 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
F |
Date |
2021-03-29 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2021-03-29 |
Time |
16:22 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2021-03-29 |
Time |
15:59 |
Sent To |
|
|
Notes |
2021-03-29 16:25:24 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | FLORIDA BUILDING CODE 2017 6TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | NFPA 70 2014 EDITION | | | | JAKE LEAHY BN, BU, PX | | ELECTRICAL PLANS EXAMINER II | | 561-805-6713 | | [email protected] | | | | PLANS SUBMITTED ARE FOR THREE DIFFEFERNT ADDRESSES | | PLEASE PICK ONE AND STAY WITH IT. | | | | IS IT FOR A 10HP PUMP OR A 1.5HP PUMP PLEASE CLARIFY | | BEFORE RESUBMITTING. | | | | PULL OUT PLANS THAT DO NOT HAVE ANYTHING TO DO WITH | | THIS ADDRESS. | | | | DO NOT RESUB PLANS WITHOUT THE RIGHT INFORMATION AND | | PLANS NEED TO BE SIGNED BY THE QUALIFIER. IF IT FAILS | | AGAIN THE NEXT TIME A 4X THE FEE WILL BE ACCESSED FOR | | MULITPLE REVIEWS. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2021-02-12 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2021-02-12 |
Time |
16:35 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2021-02-12 |
Time |
16:35 |
Sent To |
|
|
Notes |
2021-03-24 14:57:53 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | FLORIDA BUILDING CODE 2017 6TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | NFPA 70 2014 EDITION | | | | JAKE LEAHY BN, BU, PX | | ELECTRICAL PLANS EXAMINER II | | 561-805-6713 | | [email protected] | | | | 1) LOAD CALCULATION NEEDED ADDING A 10HP PUMP TO | | SERVICE. | | | | PROVIDE LOAD CALCULATION FOR SERVICE, INCLUDE EXISTING | | AND NEW LOADS TO CONFIRM CAPACITY OF SERVICE IS | | ADEQUATE. NEC 215.2, 220, 408.30; FBC RE3602.3 | | | | 2) VALUE OF PERMIT IS LOW FOR A 10HP PUMP. | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2021-01-12 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2021-01-12 |
Time |
16:22 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2021-01-12 |
Time |
16:06 |
Sent To |
|
|
Notes |
2021-01-12 16:26:41 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | FLORIDA BUILDING CODE 2017 6TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | NFPA 70 2014 EDITION | | | | JAKE LEAHY BN, BU, PX | | ELECTRICAL PLANS EXAMINER II | | 561-805-6713 | | [email protected] | | | | 1) LOAD CALCULATION NEEDED ADDING A 10HP PUMP TO | | SERVICE. | | | | PROVIDE LOAD CALCULATION FOR SERVICE, INCLUDE EXISTING | | AND NEW LOADS TO CONFIRM CAPACITY OF SERVICE IS | | ADEQUATE. NEC 215.2, 220, 408.30; FBC RE3602.3 | | | | 2) VALUE OF PERMIT IS LOW FOR A 10HP PUMP. | | | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
7 |
Status |
N |
Date |
2021-04-12 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-04-12 |
Time |
09:27 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-04-09 |
Time |
09:13 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2021-04-08 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2021-04-08 |
Time |
09:08 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2021-04-07 |
Time |
16:03 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2021-04-06 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2021-04-06 |
Time |
13:15 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2021-04-01 |
Time |
10:21 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2021-03-29 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2021-03-29 |
Time |
16:29 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2021-03-25 |
Time |
08:28 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2021-02-12 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2021-02-12 |
Time |
16:37 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2021-02-09 |
Time |
12:18 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2021-01-12 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2021-01-12 |
Time |
16:30 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2021-01-04 |
Time |
08:46 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2020-09-08 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2020-09-08 |
Time |
09:44 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2020-09-05 |
Time |
14:45 |
Sent To |
|
|
Notes |
2020-09-05 14:45:26 | ROUTED TO PLUMBING BIN |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2020-09-08 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2020-09-08 |
Time |
09:44 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2020-09-08 |
Time |
09:44 |
Sent To |
|
|
Notes |
2020-09-08 09:45:30 | 09/08/20 REVIEWED FOR CODE COMPLIANCE | | (PLUMBING/IRRIGATION) | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM | | THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND | | NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF | | PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY | | ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | AVOID VOIDING OF THE PERMIT. | | | | LUIS A. CRESPO | | PLUMBING PLAN EXAMINER / INSPECTOR | | EMAIL: [email protected] OFFICE: 561 805-6720 | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
6 |
Status |
P |
Date |
2021-04-12 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-04-12 |
Time |
09:27 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-04-12 |
Time |
09:23 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
5 |
Status |
F |
Date |
2021-04-08 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2021-04-08 |
Time |
09:07 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2021-04-08 |
Time |
09:07 |
Sent To |
|
|
Notes |
2021-04-08 09:08:44 | PLEASE HAVE A SIGNATURE ON THE DRAWING OF THE PERSON | | DESIGNING THE SYSTEM, NOT IN ACCORDANCE WITH FLORIDA | | ADMINISTRATIVE CODE 61G15-23.001, FLORIDA STATUTE 471 | | PER THE WPB AMENDMENTS TO THE FBC SEC. 107.1 GENERAL. | | | | REFER TO PREVIOUS COMMENT |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
4 |
Status |
F |
Date |
2021-04-05 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2021-04-05 |
Time |
13:01 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2021-04-05 |
Time |
13:01 |
Sent To |
|
|
Notes |
2021-04-05 13:12:28 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | FLORIDA BUILDING CODE 2017 6TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | NFPA 70 2014 EDITION | | | | JAKE LEAHY BN, BU, PX | | ELECTRICAL PLANS EXAMINER II | | 561-805-6713 | | [email protected] | | | | LINDSEY PLAN NOT SIGNED. |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
F |
Date |
2021-03-29 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2021-03-29 |
Time |
16:28 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2021-03-29 |
Time |
16:28 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
F |
Date |
2021-02-12 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2021-02-12 |
Time |
16:36 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2021-02-12 |
Time |
16:36 |
Sent To |
|
|
Notes |
2021-02-12 16:37:10 | SEE LAST REVIEW COMMENTS. |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2021-01-12 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2021-01-12 |
Time |
16:10 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2021-01-12 |
Time |
16:06 |
Sent To |
|
|
Notes |
2021-01-12 16:11:24 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | FLORIDA BUILDING CODE 2017 6TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | NFPA 70 2014 EDITION | | | | JAKE LEAHY BN, BU, PX | | ELECTRICAL PLANS EXAMINER II | | 561-805-6713 | | [email protected] | | | | PLAN IS REQUIRED TO BE SIGNED AND SEALED BY A DESIGN | | PROFESSIONAL OR THE ELECTRICAL CONTRACTOR QUALIFIER. FS | | 471.003(2)(H); 471.025; FBC 107.2.1 | | | | |
|
|