Plan Review Details - Permit 20080811
Plan Review Stops For Permit 20080811
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2020-08-31 Cont ID  
Sent By rmcdouga Date 2020-08-31 Time 15:17 Rev Time 0.00
Received By rmcdouga Date 2020-08-31 Time 15:16 Sent To  
Notes
2020-08-31 15:19:30SPOKE TO ROGER WHO WORKS FOR THE CONTRACTOR AND AGREED
 TO SELECT A DIFFERENT ROOFING ASSEMBLY IN THE SAME NOA
 THAT WAS SUBMITTED.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2020-08-31 Cont ID  
Sent By rmcdouga Date 2020-08-31 Time 09:39 Rev Time 0.00
Received By rmcdouga Date 2020-08-31 Time 09:39 Sent To  
Notes
2020-08-31 09:40:41PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC SIXTH EDITION (2017)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) THE PRODUCT APPROVAL FOR THE FLAT DECK DOES NOT
 CORRESPOND WITH THE APPLICATION. FBC 107.1.2

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-08-20 Cont ID  
Sent By shill Date 2020-08-20 Time 14:28 Rev Time 0.00
Received By shill Date 2020-08-20 Time 14:24 Sent To  
Notes
2020-08-20 14:30:04****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 1. FBC R 301, FOR THE FLAT DECK INDICATE WHICH APPROVED
 ASSEMBLY IS PROPOSED. SOME COMPONENTS WERE HIGHLIGHTED
 BUT IT IS NOT CLEAR WHICH ASSEMBLY WILL BE INSTALLED.
 IF THE PROPOSED ASSEMBLY DOES NOT MEET THE DESIGN
 PRESSURES FOR ZONES 2 AND 3 (PERIMETER AND CORNER,
 ENGINEERING WILL BE REQUIRED).
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-08-31 Cont ID  
Sent By rmcdouga Date 2020-08-31 Time 09:41 Rev Time 0.00
Received By rmcdouga Date 2020-08-24 Time 14:22 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-08-20 Cont ID  
Sent By shill Date 2020-08-20 Time 14:30 Rev Time 0.00
Received By shill Date 2020-08-19 Time 10:09 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status N Date 2020-08-31 Cont ID  
Sent By rmcdouga Date 2020-08-31 Time 15:19 Rev Time 0.00
Received By rmcdouga Date 2020-08-31 Time 15:19 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2020-08-31 Cont ID  
Sent By rmcdouga Date 2020-08-31 Time 09:40 Rev Time 0.00
Received By rmcdouga Date 2020-08-31 Time 09:40 Sent To  
Notes
2020-08-31 09:41:19ENGINEERING MAY BE REQUIRED
 IF ENGINEERING IS NOT DIGITALLY SIGNED, A PAPER
 ORIGINAL WILL BE REQUIRED (DROPPED OFF OR MAILED)
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2020-08-20 Cont ID  
Sent By shill Date 2020-08-20 Time 14:30 Rev Time 0.00
Received By shill Date 2020-08-20 Time 14:30 Sent To  
Notes
2020-08-20 14:31:14ENGINEERING MAY BE REQUIRED
 IF ENGINEERING IS NOT DIGITALLY SIGNED, A PAPER
 ORIGINAL WILL BE REQUIRED (DROPPED OFF OR MAILED)
  
  