Plan Review Details - Permit 20080726
Plan Review Stops For Permit 20080726
Review Stop G GAS REVIEW
Rev No 2 Status P Date 2020-08-25 Cont ID  
Sent By ccole Date 2020-08-25 Time 16:50 Rev Time 0.00
Received By ccole Date 2020-08-25 Time 16:50 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2020-08-20 Cont ID  
Sent By ccole Date 2020-08-20 Time 15:02 Rev Time 0.00
Received By ccole Date 2020-08-20 Time 12:28 Sent To  
Notes
2020-08-20 15:03:131ST REVIEW FBC-2017 RES.
 PERMIT- 20080726
 8/20/2020
  
 CODES IN EFFECT:
  
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH
 EDITION 2017
 FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) THE GAS ISOMETRIC SHOWS THE NEW PIPING TO THE
 GENERATOR IN COMPLIANCE, HOWEVER THE EXISTING GAS
 PIPING SHOWN FROM THE NEW REGULATOR AT 12" WC IS
 UNDERSIZED PER SECTIONS G2413.2, G2413.3, G2413.4, &
 G2413.4.1 FBC RES.
  
 A) USING THE LONGEST LENGTH METHOD, THE TOTAL DEVELOPED
 LENGTH OF THE SYSTEM IS 142 FT. FROM THE NEW REGULATOR
 TO THE MOST REMOTE OUTLET (BBQ). THE TOTAL LOAD OF THE
 SYSTEM IS 610 BTUH. BASED ON TABLE G2413.1 THE PIPE RUN
 FROM THE REGULATOR TO THE TEE, THE 12 FT. BRANCH LENGTH
 OF 1-INCH GALVANIZED PIPE RUN UP THE HOUSE WALL (277
 BTUH LOAD), AND THE 21 FT. BRANCH LENGTH OF PIPE RUN TO
 THE POOL HEATER (333 BTUH LOAD) SHALL EACH BE MINIMUM
 1-1/4 INCHES.
 BASED ON TABLE G2413.4(16) THE 70 FT. LENGTH OF 1-INCH
 CSST (277 BTUH LOAD) SHALL BE SIZED AT A MINIMUM 39
 EHD, AND ALL PIPES DOWNSTREAM OF THE CSST WILL HAVE TO
 INCREASE IN SIZE ACCORDING TO THE TABLES. PLEASE SUBMIT
 A CORRECT ISOMETRIC DRAWING.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-08-25 Cont ID  
Sent By ccole Date 2020-08-25 Time 16:50 Rev Time 0.00
Received By ccole Date 2020-08-24 Time 07:42 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2020-08-20 Time   Rev Time 0.00
Received By lmarchan Date 2020-08-17 Time 11:26 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status N Date 2020-08-25 Cont ID  
Sent By ccole Date 2020-08-25 Time 16:50 Rev Time 0.00
Received By ccole Date 2020-08-25 Time 16:50 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status N Date 2020-08-20 Cont ID  
Sent By ccole Date 2020-08-20 Time 15:05 Rev Time 0.00
Received By ccole Date 2020-08-20 Time 12:28 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status N Date 2020-08-20 Cont ID  
Sent By ccole Date 2020-08-20 Time 15:05 Rev Time 0.00
Received By ccole Date 2020-08-20 Time 12:28 Sent To  
Notes
2020-08-20 15:06:48GAS CONTRACTOR PLANS- DRAWN AND SIGNED BY CONTRACTOR.


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved