Plan Review Stops For Permit 20080541 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2020-09-03 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-09-03 |
Time |
15:15 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-09-03 |
Time |
14:42 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2020-08-26 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-08-26 |
Time |
10:15 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-08-26 |
Time |
09:49 |
Sent To |
|
|
Notes |
2020-08-26 10:17:18 | PLAN REVIEW - BUILDING | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER BUILDING - PX3169 | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | CODES IN EFFECT: | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | 1ST REVIEW | | | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. PROVIDE A STRUCTURAL REPAIR DETAIL FOR SLAB CUTS IN | | KITCHEN, M-BATH AND GUEST BATH. | | | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | 107.2.5. | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2020-09-03 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-09-03 |
Time |
15:16 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-09-03 |
Time |
14:42 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2020-08-26 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-08-26 |
Time |
10:18 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-08-26 |
Time |
09:49 |
Sent To |
|
|
Notes |
2020-08-26 10:19:58 | PLAN REVIEW - ELECTRICAL | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER BUILDING - PX3169 | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | CODES IN EFFECT: | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | 1ST REVIEW | | | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. ELECTRICAL DEVICES ARE MISSING IN GUEST BATH. SHOW | | LOCATION AND TYPE ON FLOOR PLAN. | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | 107.2.5. | | | | | | | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
N |
Date |
2020-08-21 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2020-08-21 |
Time |
16:24 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2020-08-21 |
Time |
16:24 |
Sent To |
|
|
Notes |
2020-08-21 16:25:40 | A SEPARATE PERMIT IS REQUIRED FOR THE GAS PIPING | | INSTALLTION TO THE NEW RANGE. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2020-09-03 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-09-03 |
Time |
15:16 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-08-31 |
Time |
09:22 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2020-08-26 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-08-26 |
Time |
10:20 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-08-17 |
Time |
08:28 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2020-09-01 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2020-09-01 |
Time |
13:10 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2020-09-01 |
Time |
13:09 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2020-08-25 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2020-08-25 |
Time |
11:36 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2020-08-25 |
Time |
11:11 |
Sent To |
|
|
Notes |
2020-08-25 11:39:57 | NEW KITCHEN FLOOR PLAN INDICATES A NEW HOOD ABOVE THE | | GAS RANGE. PLEASE PROVIDE MORE DETAILS ABOUT THE RANGE | | AND HOOD. IS THE HOOD VENTED TO THE OUTDOORS? IF SO, | | DOES THE RANGE REQUIRE A CERTAIN AMOUNT OF EXHAUST? | | PROVIDE THE SPEC SHEETS FOR THE NEW RANGE AND NEW HOOD. | | IF THE HOOD IS VENTED TO THE OUTDOORS A MECHANICAL SUB | | PERMIT WILL BE REQUIRED. | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2020-09-01 |
|
|
Cont ID |
|
Sent By |
abelisle |
Date |
2020-09-01 |
Time |
09:53 |
Rev Time |
0.00 |
Received By |
abelisle |
Date |
2020-09-01 |
Time |
09:22 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2020-08-21 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2020-08-21 |
Time |
15:33 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2020-08-21 |
Time |
14:13 |
Sent To |
|
|
Notes |
2020-08-21 15:34:49 | 1ST REVIEW FBC-2017 RES. | | PERMIT-20080541 | | 8/21/2020 | | | | CODES IN EFFECT: | | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | EDITION 2017 | | FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017 | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | 2017 | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2017 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) PROVIDE PLUMBING RISER DRAWINGS FOR THE ALTERATIONS | | LISTED BELOW AS REQUIRED BY SECTION 107.3.5.3 WPB | | AMENDMENTS TO THE FBC-17: | | A) RELOCATED SINK AND DISHWASHER IN THE KITCHEN. | | B) REPLACED SHOWER AND NEW AND RELOCATED LAVATORIES IN | | THE MASTER BATH. | | | | 2) CONCERNING THE RELOCATED SHOWER DRAIN IN THE MASTER | | BATH AND THE NEW SHOWER DRAIN IN THE GUEST BATH PLEASE | | NOTE THAT THE HORIZONTAL DISTANCE FROM THE CENTERLINE | | OF THE NEW SHOWER DRAIN OUTLET TO THE CENTERLINE OF THE | | INLET OF THE EXISTING TRAP SHALL NOT EXCEED 30? ? | | SECTION P3201.6 FBC RES. | | | | 3) PROVIDE A SHOWER PLAN DETAIL PER SECTION P2709.1 & | | P2709.2. | | | | 4) PLEASE NOTE THAT THE A BACKFLOW PREVENTER IS | | REQUIRED FOR THE SUPPLY LINE TO THE ICE MAKER- P2902.1, | | AND WATER HAMMER ARRESTORS ARE REQUIRED FOR THE SUPPLY | | LINES TO THE ICE MAKER AND THE DISHWASHER- SECTION | | P2903.5. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | CHRISTOPHER L. COLE | | MECHANICAL/PLUMBING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2020-09-03 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-09-03 |
Time |
15:16 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-09-03 |
Time |
14:42 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2020-08-25 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2020-08-25 |
Time |
11:40 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2020-08-25 |
Time |
11:40 |
Sent To |
|
|
Notes |
|
|