Plan Review Stops For Permit 20080500 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2020-11-19 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2020-11-19 |
Time |
10:22 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2020-11-19 |
Time |
09:57 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2020-11-12 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2020-11-12 |
Time |
13:01 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2020-11-12 |
Time |
13:01 |
Sent To |
|
|
Notes |
2020-11-12 13:02:16 | JONATHAN BROOKS JR. | | BUILDING PLANS EXAMINER | | WORK HOURS TUESDAY & THURSDAY 7:00 AM TO 3:00 PM | | ALTERNATE: CONTACT PETER VALENTI (561) 805-6673 | | [email protected] | | | | 1ST REVIEW: FBC 2017 6TH EDITION | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | FBC B = FBC BUILDING | | FBC R = FBC RESIDENTIAL | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | CITY HALL, OR EMAIL [email protected] AND REQUEST | | THAT IT BE CONVERTED TO PROJECTDOX. | | | | 1 FBC B 107.2.1. ON THE SCHEDULE FOR INSTALLATION OF | | PROTECTIVE DEVICES OR ASSEMBLIES: PLEASE CORRECT COLUMN | | HEADING ?ANCHOR SPACING?; ??ELCO ULTRACON WITH 2.5? | | MIN. EDGE DISTANCE, C-3 CONNECTION TYPE INTO HOLLOW | | (CONCRETE) BLOCK IS NOT AN ACCEPTABLE ANCHOR CONDITION; | | PLEASE CORRECT FOR ITEMS 1-6. VERIFY ALL ANCHOR | | SPACINGS AS REQUIRED FOR CONNECTION TYPES, DESIGN | | PRESSURES, STRUCTURE TYPE AND ANCHOR TYPE USED. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2020-11-03 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2020-11-03 |
Time |
13:27 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2020-11-03 |
Time |
12:19 |
Sent To |
|
|
Notes |
2020-11-03 13:28:42 | JONATHAN BROOKS JR. | | BUILDING PLANS EXAMINER | | WORK HOURS TUESDAY & THURSDAY 7:00 AM TO 3:00 PM | | ALTERNATE: CONTACT PETER VALENTI (561) 805-6673 | | [email protected] | | | | 1ST REVIEW: FBC 2017 6TH EDITION | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | FBC B = FBC BUILDING | | FBC R = FBC RESIDENTIAL | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | CITY HALL, OR EMAIL [email protected] AND REQUEST | | THAT IT BE CONVERTED TO PROJECTDOX. | | | | 1. FBC B 107.2.1. PROVIDE DRAWING DETAIL SHOWING | | CONSTRUCTION METHOD OF PROPOSED NEW SHOWER WALLS AND | | SHOWING COMPLIANCE WITH R307.2 AND R702.4.2. | | 2. FBC R 310.4. REVISE PLAN TO SHOW REQUIRED MEANS OF | | ESCAPE. INCLUDE ROOM DESIGNATION. MUST SHOW/DESIGNATE | | ON PLANS. SECOND REQUEST. | | 3. SUBMITTED PRODUCT APPROVAL COVER PAGE FL11943-R3 IS | | FOR ACCORDION SHUTTERS; SUBMITTED PRODUCT APPROVAL | | EVALUATION REPORT AND INSTALLATION INSTRUCTIONS | | FL11398-R4 IS FOR STORM PANELS. PROVIDE A COMPLETE SET | | OF PRODUCT APPROVALS FOR THE CORRECT HURRICANE | | PROTECTION SYSTEM USED. | | 4. FBC B 107.2.1. ON THE SCHEDULE FOR INSTALLATION OF | | PROTECTIVE DEVICES OR ASSEMBLIES: COLUMN HEADING | | ?SHUTTER MOUNTING CONNECTION TYPE PER PRODUCT | | APPROVAL?; PROVIDE INFORMATION FROM PRODUCT APPROVAL, | | USE ALPHABETICAL LETTERS AND NUMBERS THAT CORRESPONDS | | WITH THE CONNECTION TYPE FOR THE TOP AND BOTTOM | | CONNECTIONS. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2020-09-03 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2020-08-20 |
Time |
07:36 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2020-08-20 |
Time |
07:36 |
Sent To |
|
|
Notes |
2020-08-25 13:01:36 | JONATHAN BROOKS JR. | | BUILDING PLANS EXAMINER | | WORK HOURS TUESDAY & THURSDAY 7:00 AM TO 3:00 PM | | ALTERNATE: CONTACT SAMANTHA HILL (561) 805-6724 | | [email protected] | | | | 1ST REVIEW: FBC 2017 6TH EDITION | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | FBC B = FBC BUILDING | | FBC R = FBC RESIDENTIAL | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | CITY HALL, OR EMAIL [email protected] AND REQUEST | | THAT IT BE CONVERTED TO PROJECTDOX. | | | | 1 FBC B 107.2.1 FOR CLARITY PROVIDE AN EXISTING FLOOR | | PLAN AND INCLUDE DEMOLITION PLAN. | | 2. FBC R 301, COMPLETE THE "SCHEDULE FOR INSTALLATION | | OF OPENING PROTECTIVE DEVICES" OR PROVIDE ALL | | INFORMATION REQUIRED IN ANOTHER FORMAT (SUCH AS EXCEL | | SPREADSHEET): | | HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B | | UILDING-PERMIT-FORMS?PAGE=2 | | 3. REVISE PLAN TO SHOW MEANS OF ESCAPE REQUIRED BY FBC | | R 310.4; INCLUDE ROOM DESIGNATION | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2020-08-27 |
|
|
Cont ID |
|
Sent By |
ppetty |
Date |
2020-08-27 |
Time |
09:34 |
Rev Time |
0.00 |
Received By |
ppetty |
Date |
2020-08-27 |
Time |
09:34 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2020-11-19 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2020-11-19 |
Time |
10:22 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2020-11-13 |
Time |
10:36 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2020-11-12 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2020-11-12 |
Time |
13:02 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2020-11-10 |
Time |
13:57 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2020-11-03 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2020-11-03 |
Time |
13:28 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2020-10-27 |
Time |
08:08 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2020-09-02 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2020-09-02 |
Time |
15:01 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2020-08-20 |
Time |
15:39 |
Sent To |
|
|
Notes |
2020-08-20 15:40:03 | ROUTED TO BLDG. MISC 1 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2020-11-16 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2020-11-16 |
Time |
09:46 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2020-11-16 |
Time |
09:37 |
Sent To |
|
|
Notes |
2020-11-16 09:46:03 | 11/16/20 REVIEWED FOR CODE COMPLIANCE (PLUMBING) | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES | | FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, | | STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT | | THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK | | OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | AVOID VOIDING OF THE PERMIT. | | | | LUIS A. CRESPO | | PLUMBING PLAN EXAMINER / INSPECTOR | | EMAIL: [email protected] OFFICE: 561 805-6720 | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2020-09-02 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2020-09-02 |
Time |
14:50 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2020-09-02 |
Time |
14:50 |
Sent To |
|
|
Notes |
2020-09-02 15:01:26 | 09/02/20 REVIEWED FOR CODE COMPLIANCE (PLUMBING) | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM | | THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND | | NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF | | PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY | | ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | AVOID VOIDING OF THE PERMIT. | | | | LUIS A. CRESPO | | PLUMBING PLAN EXAMINER / INSPECTOR | | EMAIL: [email protected] OFFICE: 561 805-6720 | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
N |
Date |
2020-11-19 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2020-11-19 |
Time |
10:22 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2020-11-19 |
Time |
09:57 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
N |
Date |
2020-11-12 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2020-11-12 |
Time |
13:02 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2020-11-12 |
Time |
13:01 |
Sent To |
|
|
Notes |
|
|