Plan Review Details - Permit 20080471
Plan Review Stops For Permit 20080471
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 2 Status P Date 2020-09-01 Cont ID  
Sent By rmcdouga Date 2020-09-01 Time 07:51 Rev Time 0.00
Received By rmcdouga Date 2020-09-01 Time 07:51 Sent To  
Notes
***NONE***

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2020-08-25 Cont ID  
Sent By jwitmer Date 2020-08-25 Time 17:30 Rev Time 0.00
Received By jwitmer Date 2020-08-25 Time 17:29 Sent To  
Notes
2020-08-25 17:30:27COMMERCIAL ASBESTOS
 TO THE BUILDING CONTRACTOR:
 PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS
 REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  
 THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO
 [email protected]. THE INFORMATION SHOULD BE IN PDF
 FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE INCLUDE
 THE PERMIT NUMBER AND ?ASBESTOS? IN THE SUBJECT LINE.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2020-09-21 Cont ID  
Sent By jwitmer Date 2020-09-21 Time 15:59 Rev Time 0.00
Received By jwitmer Date 2020-09-21 Time 15:45 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-08-25 Cont ID  
Sent By jwitmer Date 2020-08-25 Time 19:03 Rev Time 0.00
Received By jwitmer Date 2020-08-25 Time 17:28 Sent To  
Notes
2020-08-25 19:03:51WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2017 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 20080471
 ADD: 1401 FORUM WAY SUITES 730 & 740
 CONT: CHANDLER CONSTRUCTION CO.
 TEL: 561-791-6934
 E-MAIL: [email protected]
  
 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: TUES. AUGUST 25TH/ 2020
 ACTION: DENIED
  
 1) SHEET A-1.0:
 1A) THE DOOR SCHEDULE LIST THE TYPE OF DOOR NOT THE
 DOOR LOCATION THERE MAYBE MULTIPLE DOOR TYPES THERE ARE
 MULTIPLE DOOR TYPES A, B, & C DOORS. THE ISSUE IS THE
 DOOR THAT LEEDS FROM THE WAITING ROOM (100) INTO THE
 WORK AREA 111. ON THE LATCH SIDE OF THE DOOR THERE IS
 NOT THE REQUIRED 18 INCHES MANEUVERING CLEARANCES.
 2017 FBC- ACCESS. CODE 404.2.4 MANEUVERING CLEARANCES.
 DOORS. MINIMUM MANEUVERING CLEARANCES AT DOORS AND
 GATES SHALL COMPLY WITH 404.2.4. MANEUVERING CLEARANCES
 SHALL EXTEND THE FULL WIDTH OF THE DOORWAY AND THE
 REQUIRED LATCH SIDE FOR SIDE CLEARANCE. SEE FIGURE
 404.2.4.1(A).
  
 1B) THE REAR DOOR THAT LEADS FROM THE OFFICE TO THE
 CORRIDOR IDENTIFIED AS ( E ) ALSO IS MISSING THE
 REQUIRED 18 INCHES ON THE LATCH SIDE OF THE DOORWAY.
 2017 FBC- ACCESS. CODE 404.2.4 MANEUVERING CLEARANCES.
 DOORS. MINIMUM MANEUVERING CLEARANCES AT DOORS AND
 GATES SHALL COMPLY WITH 404.2.4. MANEUVERING CLEARANCES
 SHALL EXTEND THE FULL WIDTH OF THE DOORWAY AND THE
 REQUIRED LATCH SIDE FOR SIDE CLEARANCE. SEE FIGURE
 404.2.4.1(A).
  
 1C) SHEET A-1.0 SHOWS A BREAK AREA IDENTIFIED AS 110
 WHAT APPEARS TO BE A BAR SINK IN THE LEFT END OF THE
 COUNTER JUST ABUTTING THE LEFT SIDE WALL. SHEET A-2.0
 DETAIL # 2 SHOWS THE ELEVATION VIEW WITH THE SINK
 CENTERED IN THE 2 FOOT WIDE BASE CABINET THEN A
 DISHWASHER. A FORWARD APPROACH WILL NOT WORK FOR A 2
 FOOT WIDE BASE CABINET AND A SIDE APPROACH WOULD NOT
 WORK THE SINK WOULD NEED TO BE CENTERED 2 FEET FROM THE
 SIDE WALL FOR A PERSON IN A WHEELCHAIR TO BE ABLE TO
 USE THE SINK. SEE THE 2017 FBC-ACCESS. CODE SECTION
 305.5 POSITION AND FIGURE 305.5.
 606.2 CLEAR FLOOR SPACE. A CLEAR FLOOR SPACE COMPLYING
 WITH 305, POSITIONED FOR A FORWARD APPROACH, AND KNEE
 AND TOE CLEARANCE COMPLYING WITH 306 SHALL BE PROVIDED,
 SEE EXCEPTIONS ALSO, BUT SHOW THE REQUIRED CLEAR FLOOR
 SPACE ON THE FLOOR PLAN.
  
 1D) BREAK ROOM CABINETRY FOUND ON A-2.0. DETAIL # 2 THE
 BREAK ROOM CABINETRY DOES NOT HAVE A VERTICAL HEIGHT AS
 DOES DETAIL # 1, WE CAN?T ASSUME THE FINISH CABINETRY
 HEIGHT NOR THE FINISH RIM HEIGHT OF THE SINK. PLEASE
 SHOW COMPLIANCE WITH 606 LAVATORIES AND SINKS> 2017
 FBC-ACCESSIBILITY CODE SECTION 606.3 HEIGHT. LAVATORIES
 AND SINKS SHALL BE INSTALLED WITH THE FRONT OF THE
 HIGHER OF THE RIM OR COUNTER SURFACE 34 INCHES (865 MM)
 MAXIMUM ABOVE THE FINISH FLOOR OR GROUND.
  
 1E) THE BREAK ROOM DETAIL FOUND ON SHEET A-2.0 DETAIL #
 2 SHOWS A MICROWAVE LOCATED 0N A SHELF IN THE UPPER
 CABINETS. THE BOTTOM SIDE OF THE SHELF THE MICROWAVE IS
 SITTING ON IS APPROXIMATELY 5 FEET ABOVE THE FINISH
 FLOOR. PLEASE SHOW HOW COMPLIANCE WILL BE MET, 2017
 FBC-ACCESS. CODE SECTIONS:
  
 1E)(1) 308 REACH RANGES.
 308.2 FORWARD REACH./ 308.2.1 UNOBSTRUCTED/ 308.2.2
 OBSTRUCTED HIGH REACH.
 308.3 SIDE REACH. / 308.3.1 UNOBSTRUCTED/ 308.3.2
 OBSTRUCTED HIGH REACH.
  
 1E)(2) 309 OPERABLE PARTS.
 309.3 HEIGHT. OPERABLE PARTS SHALL BE PLACED WITHIN ONE
 OR MORE OF THE REACH RANGES SPECIFIED IN 308.
 309.4 OPERATION. OPERABLE PARTS SHALL BE OPERABLE WITH
 ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING,
 PINCHING, OR TWISTING OF THE WRIST. THE FORCE REQUIRED
 TO ACTIVATE OPERABLE PARTS SHALL BE 5 POUNDS (22.2 N)
 MAXIMUM.
  
 1F) THE DESIGNER OF RECORD IS NOTING THAT THE CORRIDOR
 WALL IS TO BE A 1 HOUR RATED WALL, ARE THE 2 DOORS
 IDENTIFIED AS ( E ) ARE THEY GOING TO BE 20 MINUTE
 RATED? 107.2.1.2 ADDITIONAL INFORMATION REQUIRED.
  
 2) SHEET A-2-0 DETAILS 3 & 4 SHOW GLASS WINDOWS AND THE
 ONLY NOTATION IS 3/8 INCH BUTT GLAZING. PLEASE REVIEW
 IN THE 2017 FBC-B 2406 SAFETY GLAZING AND 2406.4
 HAZARDOUS LOCATIONS.
  
 3) PLEASE NOTE IF ANY OF THE ABOVE COMMENTS FOR
 ACCESSIBILITY ARE AN EXISTING CONDITION THEN THE
 ACCESSIBILITY CODE UNDER DISPROPORTIONATE COST WOULD
 ALLOW FOR THESE CONDITIONS TO BE CORRECTED. THE
 CONTRACT VALUE FOR THIS PROJECT IS $120,000.00 DOLLARS
 DISPROPORTIONATE COST WOULD ALLOW UP TO $24,000.00
 DOLLARS TO CORRECT THESE CODE ISSUES.
 DISPROPORTIONATE COST 202.4.1. PLEASE REVIEW HOW YOU
 ARE TO MEET DISPROPORTIONATE COST. EITHER THE
 CONTRACTOR OR THE DESIGNER OF RECORD ON THEIR
 LETTERHEAD NEED TO SHOW HOW THEY ARE GOING TO SPEND UP
 TO THE 20% DISPROPORTIONATE FUNDS LISTED FOR EACH
 ELEMENT WHERE THE FUNDS ARE BEING SPENT AND IN THE
 ORDER LISTED IN SECTION 202.4.1 DISPROPORTIONATE COST
 OF THE 2017 ACCESSIBILITY CODE.
  
 4) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID
 19
 IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS
 561-718-9724.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2020-08-27 Cont ID  
Sent By jleahy Date 2020-08-27 Time 11:43 Rev Time 0.00
Received By jleahy Date 2020-08-27 Time 11:35 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2020-08-11 Cont ID  
Sent By pleduc Date 2020-08-11 Time   Rev Time 0.00
Received By pleduc Date 2020-08-11 Time 15:35 Sent To  
Notes
2020-08-11 15:48:16THE PROPOSED PROJECT SHALL MEET THE REQUIREMENTS OF THE
 6TH EDITION OF FLORIDA FIRE PREVENTION CODE WHICH
 INCLUDES THE 2015 EDITION OF NFPA 1 AND NFPA 101.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date   Cont ID  
Sent By   Date 2020-09-21 Time 15:58 Rev Time 0.00
Received By lmarchan Date 2020-09-14 Time 09:39 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-08-27 Cont ID  
Sent By jleahy Date 2020-08-27 Time 11:44 Rev Time 0.00
Received By jleahy Date 2020-08-10 Time 15:33 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2020-08-18 Cont ID  
Sent By medwards Date 2020-08-18 Time 10:46 Rev Time 0.00
Received By medwards Date 2020-08-18 Time 09:15 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2020-09-21 Cont ID  
Sent By jwitmer Date 2020-09-21 Time 15:54 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2020-08-18 Cont ID  
Sent By medwards Date 2020-08-18 Time 10:50 Rev Time 0.00
Received By medwards Date 2020-08-18 Time 10:50 Sent To  
Notes
***NONE***