Plan Review Details - Permit 20080470
Plan Review Stops For Permit 20080470
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2020-10-14 Cont ID  
Sent By shill Date 2020-10-14 Time 20:00 Rev Time 0.00
Received By shill Date 2020-10-14 Time 20:00 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2020-10-03 Cont ID  
Sent By cthroop Date 2020-10-03 Time 07:53 Rev Time 0.00
Received By cthroop Date 2020-10-03 Time 07:26 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2020-09-01 Cont ID  
Sent By cthroop Date 2020-09-01 Time 16:31 Rev Time 0.00
Received By cthroop Date 2020-09-01 Time 16:09 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2020-10-15 Cont ID  
Sent By cthroop Date 2020-10-15 Time 06:32 Rev Time 0.00
Received By cthroop Date 2020-10-15 Time 06:09 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2020-09-01 Cont ID  
Sent By cthroop Date 2020-09-01 Time 16:31 Rev Time 0.00
Received By cthroop Date 2020-09-01 Time 15:36 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2020-08-24 Cont ID  
Sent By cthroop Date 2020-08-24 Time 13:22 Rev Time 0.00
Received By cthroop Date 2020-08-24 Time 13:22 Sent To  
Notes
2020-08-24 13:27:46PLAN REVIEW - ELECTRICAL
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER BUILDING - PX3169
 PLANS EXAMINER 1&2 FAMILY - SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 1ST REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. PROVIDE AN ELECTRICAL PLAN.
 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS
 SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH
 107.2.5.
  
 2. PROVIDE A RISER DIAGRAHM.
 PROVIDE RISER DIAGRAM, SHOWING ALL DETAILS OF SERVICE
 EQUIPMENT, UNDERGROUND OR OVERHEAD SERVICE, WIRE AND
 BREAKER SIZES FOR SERVICE AND FEED TO ANY SUB-PANEL(S).
 SHOW GEC SIZE AND SYSTEM, SHOW INTERSYSTEM BONDING
 TERMINATION POINT. NEC 215.5, 230, 250.50, 250.94,
 408.30; FBC RE E3706.1, E3608.1, E3609.3; WPB FBC
 107.2.1
  
 3. PROVIDE NEW LOAD CALC'S.
 PROVIDE ACCURATE LOAD CALCULATIONS INCLUDING ALL LOADS
 FOR THE SERVICE AS WELL AS THE LOAD CALCULATIONS FOR
 THE INDIVIDUAL PANELS. NEC 220; FBC RE 3602.2.
  
 4. PROVIDE PANEL SCHEDULE
 PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED
 CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS,
 AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY
 WITH CODE. NEC 210.8, 210.12, 210.19, 210.20, 215.5,
 408.4; WPB FBC 107.3.5; FBC RE E3706.2, E3902.
  
 5. IDENTIFY LOCATION OF METER, SERVICE DISCONNET AND
 PANEL ON PLAN.
 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS
 SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH
 107.2.5.

Review Stop HIST HISTORICAL
Rev No 2 Status P Date 2020-09-25 Cont ID  
Sent By fmittner Date 2020-09-25 Time 16:00 Rev Time 0.00
Received By fmittner Date 2020-09-25 Time 16:00 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 1 Status F Date 2020-08-28 Cont ID  
Sent By fmittner Date 2020-08-28 Time 09:12 Rev Time 0.00
Received By fmittner Date 2020-08-28 Time 09:12 Sent To  
Notes
2020-08-28 09:17:18HISTORIC PROPERTY IN NORTHWEST DISTRICT.
 WOOD SIDING SHALL BE REPAIRED AND IN LIMITED LOCATIONS
 WHERE REPLACEMENT IS WARRANTED NEED TO MATCH ORIGINAL
 IN WOOD WITH SAME WIDTH AND PROFILE. HARDI BOARD
 REQUIRES HPB APPROVAL.
 NEED ADDITIONAL INFORMATION ON WINDOWS.....CONFIRM
 WHITE FRAME COLOR, GRID PATTERN? MUNTIN PROFILE? CLEAR
 GLASS, LOW-E ONLY ON SIDES AND REAR.
  
 QUESTIONS, CONTACT: FRIEDERIKE MITTNER, CITY HISTORIC
 PRESERVATION PLANNER
 (561) 822-1457
  

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2020-10-15 Cont ID  
Sent By cthroop Date 2020-10-15 Time 06:32 Rev Time 0.00
Received By cthroop Date 2020-10-14 Time 10:35 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2020-10-03 Cont ID  
Sent By cthroop Date 2020-10-03 Time 07:53 Rev Time 0.00
Received By cthroop Date 2020-09-23 Time 07:40 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-09-01 Cont ID  
Sent By cthroop Date 2020-09-01 Time 16:34 Rev Time 0.00
Received By cthroop Date 2020-08-26 Time 15:58 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-08-26 Cont ID  
Sent By lmarchan Date 2020-08-26 Time 13:52 Rev Time 0.00
Received By lmarchan Date 2020-08-14 Time 07:24 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2020-10-14 Cont ID  
Sent By shill Date 2020-10-14 Time 20:01 Rev Time 0.00
Received By shill Date 2020-10-14 Time 20:01 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2020-10-03 Cont ID  
Sent By cthroop Date 2020-10-03 Time 07:53 Rev Time 0.00
Received By cthroop Date 2020-10-03 Time 07:26 Sent To  
Notes
2020-10-03 07:55:13PLAN REVIEW - SIGNATURES
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER BUILDING - PX3169
 PLANS EXAMINER 1&2 FAMILY - SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 2ND REVIEW
  
 1ST REVIEW COMMENTS HAVE NOT BEEN ADDRESSED. SEE BELOW.
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED FOR
 PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED
 ORIGINALS. A SCAN OF A WET SIGNATURE IS NOT CONSIDERED
 A DIGITAL SIGNATURE.
  
 EITHER UPLOAD A DIGITALLY SIGNED DOCUMENT OR DROP OFF
 (OR MAIL) ONE PAPER ORIGINAL:
  
 BUILDING DIVISION, FIRST FLOOR
 CITY OF WEST PALM BEACH
 401 CLEMATIS ST
 WEST PALM BEACH, FL 33401

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2020-09-01 Cont ID  
Sent By cthroop Date 2020-09-01 Time 16:31 Rev Time 0.00
Received By cthroop Date 2020-09-01 Time 16:09 Sent To  
Notes
2020-09-01 16:32:53PLAN REVIEW - SIGNATURES
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER BUILDING - PX3169
 PLANS EXAMINER 1&2 FAMILY - SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 1ST REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED FOR
 PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED
 ORIGINALS. A SCAN OF A WET SIGNATURE IS NOT CONSIDERED
 A DIGITAL SIGNATURE.
  
 EITHER UPLOAD A DIGITALLY SIGNED DOCUMENT OR DROP OFF
 (OR MAIL) ONE PAPER ORIGINAL:
  
 BUILDING DIVISION, FIRST FLOOR
 CITY OF WEST PALM BEACH
 401 CLEMATIS ST
 WEST PALM BEACH, FL 33401
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved