Plan Review Details - Permit 20080263
Plan Review Stops For Permit 20080263
Review Stop G GAS REVIEW
Rev No 2 Status P Date 2020-08-20 Cont ID  
Sent By lcrespo Date 2020-08-20 Time 11:50 Rev Time 0.00
Received By lcrespo Date 2020-08-20 Time 11:48 Sent To  
Notes
2020-08-20 11:51:3208/20/20 REVIEWED FOR CODE COMPLIANCE (GAS)
  
 BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE
 COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN
 PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM
 THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND
 NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF
 PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY
 ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM
 REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES
 / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO
 AVOID VOIDING OF THE PERMIT.
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2020-08-08 Cont ID  
Sent By medwards Date 2020-08-08 Time 09:12 Rev Time 0.00
Received By medwards Date 2020-08-08 Time 08:53 Sent To  
Notes
2020-08-08 09:12:481ST REVIEW FBC-2017 MECHANICAL
 PERMIT-20080263
  
 CODES IN EFFECT:
  
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH
 EDITION 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) IS THIS A LIKE FOR LIKE CHANGE OUT? IF SO PLEASE
 PROVIDE DETAILS OF EXISTING WATER HEATER. IF NOT PLEASE
 SUBMIT A DRAWING OF HOME WITH LOCATION OF WATER HEATER.
 ALSO PLEASE PROVIDE A GAS LINE DIAGRAM SHOWING THE
 WATER HEATER AND THE BTU?S OF BOTH THE EXISTING AND THE
 NEW WATER HEATER. FBC FS 107.2.1
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD
 SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER
 SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN
 THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS
 PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS
 PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR
 UPDATED.
  
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-08-20 Cont ID  
Sent By lcrespo Date 2020-08-20 Time 11:48 Rev Time 0.00
Received By lcrespo Date 2020-08-13 Time 08:52 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-08-12 Cont ID  
Sent By lcrespo Date 2020-08-12 Time 16:43 Rev Time 0.00
Received By lcrespo Date 2020-08-12 Time 16:43 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status N Date 2020-08-20 Cont ID  
Sent By lcrespo Date 2020-08-20 Time 11:48 Rev Time 0.00
Received By lcrespo Date 2020-08-20 Time 11:48 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status N Date 2020-08-12 Cont ID  
Sent By lcrespo Date 2020-08-12 Time 16:42 Rev Time 0.00
Received By lcrespo Date 2020-08-12 Time 16:41 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status N Date 2020-08-12 Cont ID  
Sent By lcrespo Date 2020-08-12 Time 16:43 Rev Time 0.00
Received By lcrespo Date 2020-08-12 Time 16:43 Sent To  
Notes
***NONE***