Plan Review Details - Permit 20080154
Plan Review Stops For Permit 20080154 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2020-09-14 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2020-09-14 |
Time |
15:51 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2020-09-14 |
Time |
13:33 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2020-08-19 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2020-08-19 |
Time |
07:27 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2020-08-19 |
Time |
07:17 |
Sent To |
|
|
Notes |
2020-08-19 07:30:12 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | | | 1. NOA 17-0207.02 INCLUDES TWO ASSEMBLIES; THE ONE | | PROPOSED WAS NOT INDICATED. HOWEVER, C1 CANNOT BE USED | | AS THE DESIGN PRESSURE LIMITATION IS TOO LOW FOR ZONES | | 2 AND 3 AND GENERAL LIMITATION #9 IS NOTED (CANNOT | | UTILIZE ENHANCED FASTENING). | | | | SYSTEM D1 (PAGES 7-8) HAS A LIMITATION OF -67.5 FOR | | FASTENER #1, -52.5 FOR FASTENER #2. BOTH REQUIRE | | ENGINEERING, SEE GENERAL LIMITATION #7. | | | | 2. FBC 107, PRODUCT APPROVALS ARE TO BE REVIEWED BY | | DESIGNER OF RECORD. | | | | 3. SCOPE NOT CLEAR; THE APPLICATION STATES THIS IS A | | REROOF. THE MASTER PERMIT WAS FOR PORTE COCHERE | | REPLACEMENT. DOES THIS APPLICATION INCLUDE WORK IN | | ADDITION TO THE PORTE COCHERE? IF YES, PROVIDE VALUE | | THAT WAS NOT INCLUDED IN THE MASTER PERMIT, FBC 109. | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2020-09-14 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2020-09-14 |
Time |
15:51 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2020-08-28 |
Time |
13:28 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2020-08-19 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2020-08-19 |
Time |
07:33 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2020-08-05 |
Time |
16:30 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2020-09-14 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2020-09-14 |
Time |
15:51 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2020-09-14 |
Time |
13:33 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2020-08-19 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2020-08-19 |
Time |
07:31 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2020-08-19 |
Time |
07:30 |
Sent To |
|
|
Notes |
2020-08-19 07:33:16 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | FS 471, DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED | | FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED | | ORIGINALS. | | | | ENGINEERING IS REQUIRED FOR THE ENHANCED FASTENING. | | EITHER UPLOAD DIGITALLY SIGNED & SEALED ENGINEERING OR | | UPLOAD A SCAN AND DROP OFF OR MAIL THE ORIGINAL: | | | | BUILDING DIVISION, FIRST FLOOR | | CITY OF WEST PALM BEACH | | 401 CLEMATIS ST | | WEST PALM BEACH, FL 33401 | | |
|
|
|