Plan Review Details - Permit 20071492
Plan Review Stops For Permit 20071492
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date   Cont ID  
Sent By   Date 2021-01-17 Time 14:28 Rev Time 0.00
Received By jwitmer Date 2021-01-17 Time 14:15 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2020-08-09 Cont ID  
Sent By jwitmer Date 2020-08-09 Time 15:15 Rev Time 0.00
Received By jwitmer Date 2020-08-09 Time 15:01 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2021-01-21 Cont ID  
Sent By jleahy Date 2021-01-21 Time 13:12 Rev Time 0.00
Received By jleahy Date 2021-01-21 Time 13:12 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2020-08-17 Cont ID  
Sent By jleahy Date 2020-08-17 Time 16:03 Rev Time 0.00
Received By jleahy Date 2020-08-17 Time 15:35 Sent To  
Notes
2020-08-17 16:10:08FLORIDA BUILDING CODE 2017 6TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED
 NFPA 70 2014 EDITION
  
 JAKE LEAHY BN, BU, PX
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
 1) PROVIDE LOAD CALCULATION FOR SERVICE, INCLUDE
 EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF SERVICE
 IS ADEQUATE. NEC 215.2, 220, 408.30;
  
 2) PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED
 CIRCUITS 210.8, 210.12, 215.5, 408.4
  
 3) PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR EACH
 PANEL INCLUDING INFORMATION FROM THE POWER COMPANY
 STATING WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR
 THE SERVICE TO CONFIRM THE STATED AIC RATING OF THE
 SERVICE EQUIPMENT AND DOWNSTREAM PANELS IS ADEQUATE.
 NEC 110.9, 110.10
  
 4) SOME AREAS LOOK TO BE WET LOCATIONS ALL RECEPTACLE
 OULETS TO BE GFCI PROTECTED PER 210.8
  
 5) PROVIDE A NOTE TO INDICATE COMPLIANCE WITH FBC CE
 405.2 AUTOMATIC LIGHTING CONTROL AND LIGHTING DENSITIES
 PER CODE SECTION.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-01-21 Cont ID  
Sent By jleahy Date 2021-01-21 Time 13:13 Rev Time 0.00
Received By jleahy Date 2021-01-15 Time 15:27 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-08-17 Cont ID  
Sent By jleahy Date 2020-08-17 Time 16:10 Rev Time 0.00
Received By jleahy Date 2020-08-03 Time 10:28 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2021-01-19 Cont ID  
Sent By medwards Date 2021-01-19 Time 06:53 Rev Time 0.00
Received By medwards Date 2021-01-19 Time 06:44 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2020-08-07 Cont ID  
Sent By medwards Date 2020-08-07 Time 12:02 Rev Time 0.00
Received By medwards Date 2020-08-07 Time 11:20 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date   Cont ID  
Sent By   Date 2021-01-17 Time 14:27 Rev Time 0.00
Received By jwitmer Date 2021-01-17 Time 14:15 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2020-08-07 Cont ID  
Sent By medwards Date 2020-08-07 Time 12:03 Rev Time 0.00
Received By medwards Date 2020-08-07 Time 12:03 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved