Plan Review Details - Permit 20071404
Plan Review Stops For Permit 20071404 |
Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
Rev No |
1 |
Status |
P |
Date |
2020-08-19 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2020-08-19 |
Time |
14:22 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2020-08-19 |
Time |
14:18 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2020-08-20 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2020-08-20 |
Time |
12:01 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2020-08-20 |
Time |
12:01 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2020-08-19 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2020-08-19 |
Time |
14:49 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2020-08-19 |
Time |
14:18 |
Sent To |
|
|
Notes |
2020-08-19 14:49:45 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | 1. SEWER LATERAL CAPPING FINAL INSPECTION REQUIRED; | | SCHEDULE A FINAL PLUMBING #703. PLEASE RESUBMIT AFTER | | FINAL INSPECTION HAS PASSED). | | |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
1 |
Status |
P |
Date |
2020-08-19 |
|
|
Cont ID |
|
Sent By |
rrossano |
Date |
2020-08-19 |
Time |
|
Rev Time |
|
Received By |
rrossano |
Date |
2020-08-19 |
Time |
|
Sent To |
I |
|
Notes |
2020-08-19 16:10:34 | PASSED WITH PROVISOS: | | | | PLEASE ADDRESS BUILDING COMMENTS. | | | | MAINTAIN STORMWATER POLLUTION CONTROL PLAN ONSITE | | SHOWING: | | | | A) WHERE SILT SCREENS WILL BE INSTALLED, | | B) SHOW THE PROTECTION OF ALL ON-SITE CATCH BASINS | | C) SHOW PROTECTION OF ALL OFF-SITE CATCH BASINS | | D) INCLUDE DETAILS AS TO THE TYPE OF PROTECTION USED ON | | THE CATCH BASINS | | E) SHOW HOW SITE DIRT WILL NOT BE TRACKED INTO THE | | ROADS | | | | HTTP://WWW.DEP.STATE.FL.US/WATER/STORMWATER/NPDES/DOCS/ | | CONST_ACTIVITY.PDF | | HTTP://WWW.PBCO-NPDES.ORG/CONSTRUN.HTML | | HTTP://WWW.DEP.STATE.FL.US/WATER/STORMWATER/NPDES/FAQS. | | HTM | | | | THERE ARE WATER AND SEWER LINES IN THE VICINITY OF THIS | | PROJECT. PER CHAPTER 556 OF THE FLORIDA STATE STATUTES, | | YOU MUST CALL 811 FOR UTILITY LOCATES AT LEAST TWO FULL | | BUSINESS DAYS IN ADVANCE OF ANY CONSTRUCTION OR | | DEMOLITION WORK. MORE INFORMATION CAN BE FOUND HERE: | | HTTP://WWW.SUNSHINE811.COM/ | | | | FEEL FREE TO CONTACT US IF YOU HAVE ANY QUESTIONS OR | | CONCERNS, THANKS. | | | | RICK ROSSANO | | PROJECT COORDINATOR | | ENGINEERING SERVICES DEPARTMENT | | 401 CLEMATIS STREET, 4TH FLOOR | | WEST PALM BEACH, FL 33401 | | (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402) | | MAIN PHONE: (561) 822-1200 | | DIRECT: (561) 494-1098 | | FAX: (561) 494-1116 | | MOBILE: (561) 246-9525 | | EMAIL: [email protected] | | WWW.WPB.ORG/ENGINEERING | | |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
P |
Date |
2020-08-04 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2020-08-04 |
Time |
14:27 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2020-08-04 |
Time |
14:26 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2020-08-20 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2020-08-20 |
Time |
12:01 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2020-07-30 |
Time |
09:48 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
N |
Date |
2020-08-19 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2020-08-19 |
Time |
14:49 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2020-08-19 |
Time |
14:51 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2020-08-04 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2020-08-04 |
Time |
14:28 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2020-08-04 |
Time |
14:28 |
Sent To |
|
|
Notes |
2020-08-04 14:30:43 | IT IS IMPORTANT TO NOTE THAT THIS PROPERTY IS | | NON-CONFORMING WITH THE CITY'S CURRENT ZONING AND LAND | | DEVELOPMENT REGULATIONS. WITH THE REMOVAL OF THE REAR | | STRUCTURE, AND THE UNITS CONTAINED THEREIN, THEY WILL | | NOT BE ABLE TO BE RE-BUILT. WITH THE RESIDENTIAL | | DWELLING AT THE FRONT OF THE PROPERTY, NO ADDITIONAL | | DWELLING UNITS WILL BE ABLE TO BE CONSTRUCTED. | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | 401 CLEMATIS STREET - P.O. BOX 3147 | | WEST PALM BEACH, FLORIDA 33402 | | | | P: 561.822.1448 | | TTY: 800.955.8771 | | E: [email protected] | | | | W: WPB.ORG | | |
|
|
|