Plan Review Details - Permit 20071177
Plan Review Stops For Permit 20071177 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2020-08-14 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2020-08-14 |
Time |
14:42 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2020-08-14 |
Time |
14:42 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2020-08-05 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2020-08-05 |
Time |
17:29 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2020-08-05 |
Time |
17:29 |
Sent To |
|
|
Notes |
2020-08-05 17:43:06 | PLAN | | REVIEW COMMENTS | | | | 1ST REVIEW: FBC SIXTH EDITION (2017) | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY BUILDING | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) HI LIGHT OR CIRCLE ALL OF THE APPROPIATE ITEMS IN | | THE PRODUCT APPROVAL INCLUDING THE DESIGN PRESSURE AND | | TYPE OF INSULATION. FBC 107.2 | | | | 2) THE ROOFING SYSTEM THAT WAS SUBMITTED TYPE A(4) ON | | PAGES15-16 OF THE PRODUCT APPROVAL REQUIRES AT LEAST | | ONE LAYER OF THE LISTED INSULATIONS. THE MAXIMUM DESIGN | | PRESSURE FOR THIS SYSTEM IS -60 PSF, WHICH IS TOO LOW | | FOR THE PERIMETER AND CORNER ROOF AREAS. THE LIMITATION | | #7 REQUIRES THAT SIGNED AND SEALED CALCULATIONS ARE | | SUBMITTED FOR ENHANCED FASTENING IN THESE AREAS TO | | INCREASE THE DESIGN PRESSURES. SUBMIT THE REQUIRED | | DOCUMENTS. FBC 107.2 | | | | 3) SUBMIT A ROOF DIAGRAM OF THE BUILDING. SPECIFY THE | | ROOF HEIGHT AND SHOW DIMENSIONS OF THE ROOF. INDICATE | | ANY ROOF DRAINS, PARAPET WALLS, SCUPPERS, ETC. FBC | | 107.2.1 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2020-08-14 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2020-08-14 |
Time |
14:43 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2020-08-06 |
Time |
14:00 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2020-08-05 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2020-08-05 |
Time |
17:43 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2020-07-27 |
Time |
10:51 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
N |
Date |
2020-08-14 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2020-08-14 |
Time |
14:42 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2020-08-14 |
Time |
14:42 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2020-08-05 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2020-08-05 |
Time |
17:28 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2020-08-05 |
Time |
17:28 |
Sent To |
|
|
Notes |
2020-08-05 17:29:12 | SIGNED AND SEALED RAS 117 CALCULATIONS ARE REQUIRED BY | | PRODUCT APPROVAL. |
|
|
|