Plan Review Details - Permit 20071096
Plan Review Stops For Permit 20071096
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 2 Status N Date 2020-10-21 Cont ID  
Sent By pvalenti Date 2020-10-21 Time 10:23 Rev Time 0.00
Received By pvalenti Date 2020-10-21 Time 10:23 Sent To  
Notes
***NONE***

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2020-08-11 Cont ID  
Sent By jwitmer Date 2020-08-11 Time 10:23 Rev Time 0.00
Received By jwitmer Date 2020-08-11 Time 10:03 Sent To  
Notes
2020-08-11 10:23:01COMMERCIAL ASBESTOS
 PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS
 REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  
 THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO
 [email protected]. THE INFORMATION SHOULD BE IN PDF
 FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE INCLUDE
 THE PERMIT NUMBER AND ?ASBESTOS? IN THE SUBJECT LINE.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2020-10-21 Cont ID  
Sent By pvalenti Date 2020-10-21 Time 10:23 Rev Time 0.00
Received By pvalenti Date 2020-10-21 Time 09:33 Sent To  
Notes
2020-10-21 10:39:26PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
 FBC M = FBC MECHANICAL
 FBC FG = FBC FUEL GAS
  
 BUILDING REVIEW APPROVED WITH PROVISO:
  
 THE APPROVAL IS ONLY FOR AREA OF WORKED AS MARKED ON
 SUBMITTED PLAN,THE SUBMITTAL OF ADDITIONAL COMMENTS MAY
 RESULT IN NEW PLAN REVIEW COMMENTS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-08-11 Cont ID  
Sent By jwitmer Date 2020-08-11 Time 10:43 Rev Time 0.00
Received By jwitmer Date 2020-08-11 Time 10:01 Sent To  
Notes
2020-08-11 10:04:24 
 WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2017 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 20071096
 ADD: 1551 N FLAGLER DR. SUITE # 805
 CONT: LA ROCCCA CONSTRUCTION LLC
 TEL: 954-980-0755
 E-MAIL: [email protected]
  
 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: TUES. AUGUST 11TH/ 2020
 ACTION: DENIED
 1) PLANS THAT ARE NOT DESIGNED BY ARCHITECTS OR
 ENGINEERS BUT BY CONTRACTORS MUST COMPLY WITH THE
 FOLLOWING REQUIREMENTS. 107.3.4.3 CERTIFICATION BY
 CONTRACTOR. PLEASE NOTE THE EXCEPTION TO ENGINEERED
 PLANS UNDER 471.003(H) ELECTRICAL/ PLUMBING/
 MECHANICAL, 481.229(1)(C) (BUILDING) REQUIRES THE
 CONTRACTOR FOR THAT TRADE THAT WILL BE LICENSED IN THAT
 TRADE, WILL ALSO BE THE CONTRACTOR THAT DESIGNS THE
 SYSTEM UNDER THAT TRADE. THE CONTRACTOR (QUALIFIER)
 THAT CREATED / DRAWN THE SET OF PLANS WILL NEED TO
 IDENTIFY THEMSELVES AS THE AUTHOR OF THE PLANS. PLEASE
 PRINT YOUR NAME, SIGN YOUR NAME AND LICENSE NUMBER FOR
 THE TRADE YOU ARE LICENSED IN AND PLANS DRAWN. FOR EACH
 TRADE THE CONTRACTOR RESPONSIBLE FOR THE DESIGN UNDER
 THE TRADE LICENSED IN MUST PRINT THEIR NAME, SIGN THEIR
 NAME AND LICENSE NUMBER, NOTE THESE PLANS APPEAR TO BE
 DRAWN BY ONE INDUVIAL, THEY WOULD HAVE TO BE LICENSED
 AS A BUILDING, ELECTRICAL AND PLUMBING CONTRACTOR TO
 SUBMIT ALL THESE TRADES UNDER ONE SHEET.
 2) THE PERSON UPLOADING PLANS AND DOCUMENTS HAS LOADED
 THE DOCUMENTS WRONG. FOR EXAMPLE FOR THEE FLOOR
 UNDERLAYMENTS DO NOT LOAD THEM ONE PAGE AT A TIME. ONE
 TEST ONE FOLDER. THIS GOES FOR ALL OTHER DOCUMENTS, YOU
 MAY NEED TO CONTACT THE LIBRIAN TO SEE IF ALL OF THE
 DOCUMENTS IN THE FILE FOLDER CAN BE ELIMINATED TO START
 OVER.
 107.2.1.3. QUALITY OF PLANS THE BUILDING OFFICIAL MAY
 ESTABLISH THROUGH DEPARTMENT POLICY OTHER STANDARDS FOR
 THE PLANS AND SPECIFICATIONS IN ORDER TO PROVIDE
 CONFORMITY TO ITS RECORD RETENTION PROGRAM. THIS POLICY
 MAY INCLUDE SUCH THINGS AS MINIMUM SIZE, SHAPE,
 CONTRAST, CLARITY, OR OTHER ITEMS RELATED TO RECORD
 MANAGEMENT. ELECTRONIC MEDIA MUST BE COMPATIBLE WITH
 THE ARCHIVE REQUIREMENTS OF FLORIDA STATUTES.
  
 3) OF THE 86 PAGES WHICH WERE LOADED SIDEWAYS PLEASE
 LOAD THEM SO THEY DO NOT NEED TO EACH ONE BE TURNED TO
 REVIEW THE DOCUMENTS.
 107.2.1.3. QUALITY OF PLANS. THE BUILDING OFFICIAL MAY
 ESTABLISH THROUGH DEPARTMENT POLICY OTHER STANDARDS FOR
 THE PLANS AND SPECIFICATIONS IN ORDER TO PROVIDE
 CONFORMITY TO ITS RECORD RETENTION PROGRAM. THIS POLICY
 MAY INCLUDE SUCH THINGS AS MINIMUM SIZE, SHAPE,
 CONTRAST, CLARITY, OR OTHER ITEMS RELATED TO RECORD
 MANAGEMENT. ELECTRONIC MEDIA MUST BE COMPATIBLE WITH
 THE ARCHIVE REQUIREMENTS OF FLORIDA STATUTES.
 4) THE FLOOR PLAN DOES NOT INDICATE AS TO WHAT TYPE OF
 FLOOR UNDERLAYMENT IS BEING INSTALLED NOR THE FINISH
 MATERIAL. PLEASE ADD THIS TO THE FLOOR PLAN. 107.2.1.2
 ADDITIONAL INFORMATION IS REQUIRED.
 5) IN FINDING THE 2ND PAGE OF ONE OF THE FLOOR
 UNDERLAYMENT REPORTS IT IS FOR THE WRONG FLOOR SYSTEM.
 THE REPORT INDICATES IT IS FOR A 6 INCH CONCRETE SLAB,
 BAR JOIST A DROPPED CEILING CAVITY OF 14 INCHES WITH 4
 INCHES OF INSULATION IN THE DROPPED CEILING CAVITY AND
 ? IN DRY WALL. THIS BUILDING HAS A 6 INCH CONCRETE SLAB
 ONLY, NO BAR JOIST AND NO DROPPED CEILING THROUGH THE
 WHOLE SUITE.
 FLOOR INSULATION (FBC-B 2017)
 FOR TILE, STONE, MARBLE, VINYL AND WOOD FLOORING ALL
 NEED TO HAVE HAD THE SOUND UNDERLAYMENT TESTED FLOOR
 ASSEMBLIES TO THE FOLLOWING STANDARDS AND MEET THE
 QUALIFICATIONS LISTED UNDER EACH OF THE STANDARDS FOR A
 6 INCH CONCRETE FLOOR ASSEMBLY/ NO DROPPED CEILING:
 PLEASE PROVIDE ALL THREE TEST REPORTS SHOWING
 COMPLIANCE WITH:
  
 TYPE I AND II BUILDINGS
 5A) FBC-B 2017 1207.3 STRUCTURE-BORNE SOUND.
 FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR
 BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA
 WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION
 CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD
 TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492.
  
 5B) FBC-B 2017 1207.2 AIR-BORNE SOUND.
 WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES
 SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM
 PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION
 CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED)
 FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM
 E 90.
  
 5C) FLAME SPREAD- FBC-B 2017 603.1. EXCEPTION 2.
 INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID
 DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED
 TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200.
  
 FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS
 A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL
 MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A
 MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723.
  
 LVT & LPT LUXURY VINYL TILE. FLOOR FINISH
 CLASSIFICATION AS REQUIRED IN SECTION 804.2
 CLASSIFICATION AND 804.3 TESTING AND IDENTIFICATION OF
 THE 2017 FBC-B.
  
 6) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 A THOROUGH REVIEW OF THE PLANS COULD NOT HAPPEN SINCE
 THERE WAS A GREAT DEFICIENCY IN PLANS AND REQUIRED
 DOCUMENTATION. WITH THE NEXT PLAN REVIEW CYCLE THERE
 MAYBE ADDITIONAL REVIEW COMMENTS BECAUSE OF NEW PLANS
 AND INFORMATION LACKING UNDER THE PRIOR REVIEW.
  
 PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID
 19
 IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS
 561-718-9724.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2020-10-27 Cont ID  
Sent By jleahy Date 2020-10-27 Time 11:08 Rev Time 0.00
Received By jleahy Date 2020-10-27 Time 11:08 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2020-10-21 Cont ID  
Sent By jleahy Date 2020-10-21 Time 08:25 Rev Time 0.00
Received By jleahy Date 2020-10-21 Time 08:18 Sent To  
Notes
2020-10-21 08:49:10ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 FLORIDA BUILDING CODE 2017 6TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED
 NFPA 70 2014 EDITION
  
 JAKE LEAHY BN, BU, PX
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
 SHEET A-1
  
 STILL DOES NOT SHOW ELECTRICAL WORK. IT HAS ELECTRICAL
 NOTES BUT NO WORK SHOWN.

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2020-08-13 Cont ID  
Sent By jleahy Date 2020-08-13 Time 17:36 Rev Time 0.00
Received By jleahy Date 2020-08-13 Time 17:31 Sent To  
Notes
2020-08-13 17:37:43FLORIDA BUILDING CODE 2017 6TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED
 NFPA 70 2014 EDITION
  
 JAKE LEAHY BN, BU, PX
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
 NO ELECTRICAL WORK SHOWN ON PLANS JLEAHY

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2020-10-21 Cont ID  
Sent By pleduc Date 2020-10-21 Time   Rev Time 0.00
Received By pleduc Date 2020-10-21 Time 14:04 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2020-08-04 Cont ID  
Sent By pleduc Date 2020-08-04 Time   Rev Time 0.00
Received By pleduc Date 2020-08-04 Time 14:12 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2020-11-18 Cont ID  
Sent By lcrespo Date 2020-11-18 Time 15:57 Rev Time 0.00
Received By lcrespo Date 2020-11-18 Time 15:57 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-10-21 Cont ID  
Sent By ccarvaja Date 2020-10-21 Time 16:25 Rev Time 0.00
Received By ccarvaja Date 2020-10-13 Time 14:33 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-08-14 Cont ID  
Sent By lmarchan Date 2020-08-14 Time 06:40 Rev Time 0.00
Received By lmarchan Date 2020-08-03 Time 06:59 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2020-11-18 Cont ID  
Sent By lcrespo Date 2020-11-18 Time 15:57 Rev Time 0.00
Received By lcrespo Date 2020-11-18 Time 15:57 Sent To  
Notes
2020-11-18 15:59:2411/18/20 REVIEWED FOR CODE COMPLIANCE (PLUMBING)
  
 BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE
 COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN
 PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES
 FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL,
 STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT
 THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK
 OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM
 REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES
 / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO
 AVOID VOIDING OF THE PERMIT.
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  

Review Stop P PLUMBING
Rev No 2 Status F Date 2020-10-21 Cont ID  
Sent By lcrespo Date 2020-10-21 Time 11:04 Rev Time 0.00
Received By lcrespo Date 2020-10-21 Time 09:21 Sent To  
Notes
2020-10-21 11:05:2310/21/20 1ST PLUMBING REVIEW**DENIED** WITH COMMENTS
  
 NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS
 TIME AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE
 GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS.
  
 1. A PLUMBING APPLICATION HAS BEEN SUBMITTED AND THERE
 A MECHANICAL CAC NUMBER BUT A PLUMBING CFC NUMBER THAT
 IS REQUIRED. PLEASE CHANGE AND YOU CAN EMAIL PERMIT
 LIBRARIAN TO [email protected] WITH THE
 INFORMATION REQUIRED.
  
 2. ON THE SCOPE OF WORK, YOU STATE NO MECHANICAL WORK
 IS TO BE DONE ON NEW PLANS BUT IN THE FIRST SET OF
 PLANS, YOU SHOW A WASHER AND DRYER SIDE BY SIDE. IN THE
 NEW SET OF PLANS, YOU SHOW A STACKABLE. THE VENTING FOR
 THE DRYER WILL BE ALTERED MAKING A MECHANICAL PERMIT
 REQUIRED. PLEASE SHOW ON NEW PLANS AND ADD TO THE SCOPE
 OF WORK PER THE WPB AMENDMENT TO FBC SEC. 107.2.1.3
 QUALITY OF BUILDING PLANS.
  
 3. THE WASHING MACHINE IS GOING A STACKABLE COMBO AND
 THE VALVE SHALL BE ASSESSABLE WITHOUT MOVING THE UNITS,
 THIS MAY REQUIRE THE VALVES TO BE ON THE SIDE OF THE
 UNIT PER THE 2017 FBC SEC. P 606.3 ACCESS TO VALVES. A
 NEW WASHER DRAIN BOX MAY STAY IN THE BACK BUT IT HAS TO
 BE A FIRE-RATED BOX IN THAT WALL PER THE 2017 FBC SEC.
 P 606.3 ACCESS TO VALVES.
  
 HTTPS://CODES.ICCSAFE.ORG/CATEGORY/FLORIDA?YEAR%5B%5D=C
 URRENT+ADOPTION&PAGE=1
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION, MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
  
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2020-08-12 Cont ID  
Sent By lcrespo Date 2020-08-12 Time 09:55 Rev Time 0.00
Received By lcrespo Date 2020-08-12 Time 09:33 Sent To  
Notes
2020-08-12 09:55:5908/12/20 1ST PLUMBING REVIEW**DENIED** WITH COMMENTS
  
 NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS
 TIME AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE
 GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS.
  
 1. PLANS THAT ARE NOT DESIGNED BY ARCHITECTS OR
 ENGINEERS BUT BY CONTRACTORS MUST COMPLY WITH THE
 FOLLOWING REQUIREMENTS. 107.3.4.3 CERTIFICATION BY
 CONTRACTOR. PLEASE NOTE THE EXCEPTION TO ENGINEERED
 PLANS UNDER 471.003(H) ELECTRICAL/ PLUMBING/
 MECHANICAL, 481.229(1)(C) (BUILDING) REQUIRES THE
 CONTRACTOR FOR THAT TRADE THAT WILL BE LICENSED IN THAT
 TRADE, WILL ALSO BE THE CONTRACTOR THAT DESIGNS THE
 SYSTEM UNDER THAT TRADE. THE CONTRACTOR (QUALIFIER)
 THAT CREATED / DRAWN THE SET OF PLANS WILL NEED TO
 IDENTIFY THEMSELVES AS THE AUTHOR OF THE PLANS. PLEASE
 PRINT YOUR NAME, SIGN YOUR NAME AND LICENSE NUMBER FOR
 THE TRADE YOU ARE LICENSED IN AND PLANS DRAWN. FOR EACH
 TRADE THE CONTRACTOR RESPONSIBLE FOR THE DESIGN UNDER
 THE TRADE LICENSED IN MUST PRINT THEIR NAME, SIGN THEIR
 NAME AND LICENSE NUMBER, NOTE THESE PLANS APPEAR TO BE
 DRAWN BY ONE INDUVIAL, THEY WOULD HAVE TO BE LICENSED
 AS A BUILDING, ELECTRICAL AND PLUMBING CONTRACTOR TO
 SUBMIT ALL THESE TRADES UNDER ONE SHEET.
  
 2. PLEASE SHOW AND PROVIDE A NARRATIVE ON PLANS OF THE
 SCOPE OF WORK I.E., NEW SINK, NO OTHER PLUMBING WORK
 WILL BE DONE, NOT MOVING PIPES, WHO IS RESPONSIBLE FOR
 OTHER WORK, ETC., PER THE WPB AMENDMENTS TO THE FBC
 SEC. 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
  
 3. THE SUB PERMIT FOR PLUMBING HAS A LICENSE NUMBER
 PLEASE PROVIDE A CPC NUMBER UNDER THE COMPANY THE
 CONTRACTOR FOR THE SCOPE OF WORK PER THE WPB AMENDMENTS
 TO THE FBC SEC. 105.1.
  
 4. PLEASE HAVE A SIGNATURE ON THE DRAWING OF THE PERSON
 DESIGNING THE SYSTEM, NOT IN ACCORDANCE WITH FLORIDA
 ADMINISTRATIVE CODE 61G15-23.001, FLORIDA STATUTE 471
 PER THE WPB AMENDMENTS TO THE FBC SEC. 107.1 GENERAL.
  
 5. SIGNED AND SEALED DRAWINGS NEED TO BE
 DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR
 ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW - OR -
 IF YOUR ENGINEER DOES NOT HAVE A ELECTRONIC OR DIGITAL
 SIGNATURE - PLEASE DROP OFF (CITY HALL DROP BOX) THE
 ORIGINAL SIGNED AND SEALED DOCUMENT ALONG WITH A "PLAN
 REVIEW REQUEST FORM" EXPLAINING THE REASON FOR
 SUBMITTING THE DOCUMENT OR DRAWINGS. PLAN REVIEW
 REQUEST FORM CAN BE OBTAINED BY E MAILING [email protected]
 AND ASKING FOR THE FORM.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION, MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2020-10-20 Cont ID  
Sent By shill Date 2020-10-20 Time 14:32 Rev Time 0.00
Received By shill Date 2020-10-20 Time 14:32 Sent To  
Notes
2020-10-20 14:32:43PAPER ORIGINALS SUBMITTED
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2020-08-11 Cont ID  
Sent By jwitmer Date 2020-08-11 Time 10:25 Rev Time 0.00
Received By jwitmer Date 2020-08-11 Time   Sent To  
Notes
2020-08-11 10:25:37PLANS THAT ARE NOT DESIGNED BY ARCHITECTS OR ENGINEERS
 BUT BY CONTRACTORS MUST COMPLY WITH THE FOLLOWING
 REQUIREMENTS. 107.3.4.3 CERTIFICATION BY CONTRACTOR.
 PLEASE NOTE THE EXCEPTION TO ENGINEERED PLANS UNDER
 471.003(H) ELECTRICAL/ PLUMBING/ MECHANICAL,
 481.229(1)(C) (BUILDING) REQUIRES THE CONTRACTOR FOR
 THAT TRADE THAT WILL BE LICENSED IN THAT TRADE, WILL
 ALSO BE THE CONTRACTOR THAT DESIGNS THE SYSTEM UNDER
 THAT TRADE. THE CONTRACTOR (QUALIFIER) THAT CREATED /
 DRAWN THE SET OF PLANS WILL NEED TO IDENTIFY THEMSELVES
 AS THE AUTHOR OF THE PLANS. PLEASE PRINT YOUR NAME,
 SIGN YOUR NAME AND LICENSE NUMBER FOR THE TRADE YOU ARE
 LICENSED IN AND PLANS DRAWN. FOR EACH TRADE THE
 CONTRACTOR RESPONSIBLE FOR THE DESIGN UNDER THE TRADE
 LICENSED IN MUST PRINT THEIR NAME, SIGN THEIR NAME AND
 LICENSE NUMBER, NOTE THESE PLANS APPEAR TO BE DRAWN BY
 ONE INDUVIAL, THEY WOULD HAVE TO BE LICENSED AS A
 BUILDING, ELECTRICAL AND PLUMBING CONTRACTOR TO SUBMIT
 ALL THESE TRADES UNDER ONE SHEET.