Plan Review Details - Permit 20071076
Plan Review Stops For Permit 20071076 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2020-08-13 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2020-08-13 |
Time |
08:10 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2020-08-13 |
Time |
07:52 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2020-07-29 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2020-07-29 |
Time |
10:01 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2020-07-28 |
Time |
16:25 |
Sent To |
|
|
Notes |
2020-07-29 09:55:55 | PLAN | | REVIEW COMMENTS | | | | 1ST REVIEW: FBC SIXTH EDITION (2017) | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY BUILDING | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) THE TPO ROOF SYSTEM SELECTED ON PAGE 64 OF PRODUCT | | APPROVAL FL14083.1 SPECIFIES CELCORE LIGHT WEIGHT | | CONCRETE (LWC) WITH PRODUCT APPROVAL NUMBER FL2037 (SEE | | NOTE 15). THE PRODUCT APPROVAL THAT WAS SUBMITTED FOR | | THE LWC IS NOA NO. 18-0717.05. IT IS PREFERABLE THAT | | THE PRODUCT APPROVALS FOR A ROOFING SYSTEM ARE EITHER | | ALL FL # OR MIAMI-DADE NOA AS SOME HAVE DIFFERENT | | REQUIREMENTS. THE DESIGNER OF RECORD CAN PROVIDE A | | LETTER STATING THAT THE LWC IN MIAMI DADE NOA NO. | | 18-0717.05 IS EQUAL TO FL 2037 AND IS ACCEPTABLE FOR | | THIS PROJECT. FBC 107 | | | | 2) THE PAGE FROM FL 14083.1 THAT HAS NOTE A REFERENCED | | IN THE TABLE ON PAGE 64 FOR THIS SYSTEM APPEARS TO BE | | MISSING FROM THE SUBMITTAL. FBC 107 | | | | 3) HI LIGHT OR CIRCLE THE ITEMS THAT APPLY TO THIS | | INSTALLATION ON PRODUCT APPROVAL NOA NO. 18-0717.05 FOR | | THE LWC. FBC 107.2.1 | | | | 4) THE ROOF PLANS FOR THIS BUILDING SHOWS WALKING PADS. | | SHOW HOW THE TPO MEMBRANE WILL BE DESIGNED IN THESE | | AREAS TO PREVENT DAMAGE FROM THE WALKING PADS. FBC 107 | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2020-08-13 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2020-08-13 |
Time |
08:10 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2020-08-05 |
Time |
13:44 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2020-07-29 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2020-07-29 |
Time |
10:01 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2020-07-23 |
Time |
15:53 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
N |
Date |
2020-07-29 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2020-07-29 |
Time |
10:01 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2020-07-28 |
Time |
16:25 |
Sent To |
|
|
Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |