Plan Review Stops For Permit 20071059 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2020-09-16 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2020-09-16 |
Time |
10:50 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2020-09-16 |
Time |
10:50 |
Sent To |
|
|
Notes |
2020-09-16 10:51:17 | PETER E VALENTI | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6673 | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | FBC M = FBC MECHANICAL | | FBC FG = FBC FUEL GAS | | | | BUILDING REVIEW APPROVED PER TABLE SCHEDULES WITHIN | | PRODUCT APPROVALS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2020-09-15 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2020-09-15 |
Time |
11:14 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2020-09-15 |
Time |
11:14 |
Sent To |
|
|
Notes |
2020-09-15 11:14:28 | JONATHAN BROOKS JR. | | BUILDING PLANS EXAMINER | | WORK HOURS TUESDAY & THURSDAY 7:00 AM TO 3:00 PM | | ALTERNATE: CONTACT PETER VALENTI (561) 805-6673 | | [email protected] | | | | 1ST REVIEW: FBC 2017 6TH EDITION | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | FBC B = FBC BUILDING | | FBC R = FBC RESIDENTIAL | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | CITY HALL, OR EMAIL [email protected] AND REQUEST | | THAT IT BE CONVERTED TO PROJECTDOX. | | ` | | 1. FBC B 107.2.1 ON THE SCHEDULE FOR INSTALLATION OF | | PROTECTIVE DEVICES OR ASSEMBLIES: PLEASE CORRECT COLUMN | | HEADING ?SHUTTER MOUNTING CONNECTION TYPE PER PRODUCT | | APPROVAL?. WALL CONNECTION TYPES (A), (B), (C), (D), | | (E) OR (F) CANNOT BE USED FOR SHUTTER SPANS THAT | | EXCEEDS 13?-1? FOR A.S.D. DESIGN PRESSURE RATING + OR ? | | 45 P.S.F. CONNECTION TYPES ALLOWED FOR SPANS OF 168? | | ARE CONNECTION TYPE (G) (CEILING MOUNTING); (H),(I) AND | | (I1) (FLOOR MOUNTING) USING POURED CONCRETE SUBSTRATE. | | PROVIDE THE CORRECT MOUNTING CONNECTION AND ANCHOR | | SPACINGS AS PER THE CONNECTION TYPES USED. PLEASE | | CORRECT FOR ITEMS #1-4 ON THE SCHEDULE FOR INSTALLATION | | OF OPENING PROTECTIVE DEVICES OR ASSEMBLIES. SECOND | | REQUEST | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2020-08-13 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2020-08-13 |
Time |
14:31 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2020-08-13 |
Time |
14:30 |
Sent To |
|
|
Notes |
2020-08-13 14:31:16 | JONATHAN BROOKS JR. | | BUILDING PLANS EXAMINER | | WORK HOURS TUESDAY & THURSDAY 7:00 AM TO 3:00 PM | | ALTERNATE: CONTACT SAMANTHA HILL (561) 805-6724 | | [email protected] | | | | 1ST REVIEW: FBC 2017 6TH EDITION | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | FBC B = FBC BUILDING | | FBC R = FBC RESIDENTIAL | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | CITY HALL, OR EMAIL [email protected] AND REQUEST | | THAT IT BE CONVERTED TO PROJECTDOX. | | | | | | 1. FBC B 107.2.1 FOR WALL CONNECTION TYPE C/F REFER TO | | FL389.2 SHEET 11, SCHEDULE #1 OR SCHEDULE #2; MAXIMUM | | A.S.D. DESIGN PRESSURE RATING 45 THE MAXIMUM SHUTTER | | SPAN IS 13?-1?/157?. SHUTTER SPAN OF 168? EXCEEDS | | MAXIMUM SPAN ALLOWED FOR WALL MOUNTED CONNECTIONS. | | PLEASE CORRECT FOR ITEMS #1-4 ON THE SCHEDULE FOR | | INSTALLATION OF OPENING PROTECTIVE DEVICES OR | | ASSEMBLIES. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2020-07-31 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-07-31 |
Time |
09:17 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-07-31 |
Time |
09:10 |
Sent To |
|
|
Notes |
2020-07-31 09:17:37 | SHUTTERS | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected]. | | CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1 | | AMENDMENTS | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | 1) ATTACHMENT SPACING FOR THE 168" SHUTTERS USING | | CONNECTION TYPE "D" AND (-43.6 ) PRESSURE ARE NOT | | CORRECT ON THE "OPENING INSTALLATION SCHEDULE" (ALSO | | CHECK THE SHUTTER SPAN CHART FOR THE (168") SHUTTER) | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2020-09-16 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2020-09-16 |
Time |
11:07 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2020-09-15 |
Time |
14:40 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2020-09-15 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2020-09-15 |
Time |
11:14 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2020-09-02 |
Time |
16:54 |
Sent To |
|
|
Notes |
2020-09-02 16:54:53 | ROUTED TO BLDG MISC 1 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2020-08-13 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2020-08-13 |
Time |
14:32 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2020-08-12 12:25:12 | ROUTED TO BLDG. MISC 1 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2020-07-31 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-07-31 |
Time |
09:20 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-07-23 |
Time |
10:42 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2020-08-13 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2020-08-13 |
Time |
14:31 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2020-08-13 |
Time |
14:31 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2020-07-31 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-07-31 |
Time |
09:18 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-07-31 |
Time |
09:17 |
Sent To |
|
|
Notes |
2020-07-31 10:50:48 | SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE | | DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR | | ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW. | | DRAWINGS DO NOT SHOW IN "ADOBE READER" AS | | DIGITALLY/ELECTRONICALLY SIGNED. - OR - IF YOUR | | ENGINEER OR ARCHITECT DOES NOT HAVE AN ELECTRONIC OR | | DIGITAL SIGNATURE - PLEASE DROP OFF (CITY HALL DROP | | BOX) THE ORIGINAL SIGNED AND SEALED DRAWINGS/DOCUMENTS | | ALONG WITH A "PLAN REVIEW REQUEST FORM" EXPLAINING THE | | REASON FOR SUBMITTING THE DOCUMENT OR DRAWINGS. PLAN | | REVIEW REQUEST FORM CAN BE OBTAINED BY E MAILING | | [email protected] AND ASKING FOR THE FORM |
|
|