Plan Review Stops For Permit 20071007 |
Review Stop |
AD |
ADDRESSING |
Rev No |
2 |
Status |
P |
Date |
2020-08-25 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2020-08-25 |
Time |
15:15 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2020-08-25 |
Time |
15:15 |
Sent To |
|
|
Notes |
2020-08-25 15:15:53 | 8/25/20 ADDRESS CHANGED FROM 835 BELVEDERE TO 875 | | BELVEDERE TO REFLECT CITY'S ROAD CENTER LINE OF NEW | | BUILDING TO BE CONSTRUCTED. CP | | |
|
|
Review Stop |
AD |
ADDRESSING |
Rev No |
1 |
Status |
F |
Date |
2020-07-31 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2020-07-31 |
Time |
11:01 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2020-07-31 |
Time |
11:01 |
Sent To |
|
|
Notes |
2020-07-31 11:02:38 | NEW BUILDING NEWS A NEW ADDRESS, EMAILED APPLICANT WITH | | PROPOSED ADDRESS, PLEASE REACH OUT TO [email protected] TO | | DISCUSS ADDRESS POSSIBILITIES. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2023-04-05 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2023-04-05 |
Time |
09:59 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2023-04-05 |
Time |
09:59 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2023-03-08 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2023-03-08 |
Time |
08:12 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2023-03-08 |
Time |
08:13 |
Sent To |
|
|
Notes |
2023-03-08 08:12:09 | NEW COMMERCIAL BUILDING | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected] | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | AMENDMENT | | | | CORRECTIONS NEEDED - | | | | 1) PLEASE SHOW THE REQUIRED ROOF DRAINAGE OVERFLOW | | SCUPPERS - FBC 1503.4.2.1 OVERFLOW SCUPPERS. | | WHEN OTHER MEANS OF DRAINAGE OF OVERFLOW WATER IS NOT | | PROVIDED, OVERFLOW SCUPPERS SHALL BE PLACED IN WALLS OR | | PARAPETS NOT LESS THAN 2 INCHES (51 MM) NOR MORE THAN 4 | | INCHES (102 MM) ABOVE THE FINISHED ROOF COVERING AND | | SHALL BE LOCATED AS CLOSE AS PRACTICAL TO REQUIRED | | VERTICAL LEADERS OR DOWNSPOUTS OR WALL AND PARAPET | | SCUPPERS. AN OVERFLOW SCUPPER SHALL BE SIZED IN | | ACCORDANCE WITH THE FLORIDA BUILDING CODE, PLUMBING. | | | | 2) IN THE PRODUCT APPROVAL PROVIDED FOR THE FLAT DECK | | (FL10264) - THE ROOFING SYSTEM CIRCLED HAS A PRESSURE | | OF (-37.5 *) WHICH DOES NOT MEET THE REQUIRED WIND | | PRESSURES SHOWN ON DRAWING S1. | | | | 3) ALL PRODUCT APPROVALS IN PROJECTDOX NEED TO BE | | REVIEWED AND MARKED APPROVED BY THE DESIGNER OF RECORD | | OR LISTED ON THE DRAWINGS BY THE PRODUCT APPROVAL | | NUMBER - FBC WPB 107.3.4 | | | | 4) PLEASE PROVIDE THE EXTERIOR DOOR PRODUCT APPROVAL | | LISTED ON THE DRAWINGS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2023-01-12 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2023-01-12 |
Time |
09:40 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2023-01-11 |
Time |
13:11 |
Sent To |
|
|
Notes |
2023-01-12 09:40:26 | NEW COMMERCIAL BUILDING | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected] | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | AMENDMENT | | | | CORRECTIONS NEEDED - | | | | 1) PLEASE SHOW THE REQUIRED ROOF DRAINAGE OVERFLOW | | SCUPPERS - FBC 1503.4.2.1 | | | | 2) PLEASE SHOW THE WALLS SURROUNDING THE MOP SINK TO | | COMPLY WITH FBC 1210.2.2 WALLS AND PARTITIONS. | | WALLS AND PARTITIONS WITHIN 2 FEET (610 MM) OF SERVICE | | SINKS, URINALS AND WATER CLOSETS SHALL HAVE A SMOOTH, | | HARD, NONABSORBENT SURFACE, TO A HEIGHT OF NOT LESS | | THAN 4 FEET (1219 MM) ABOVE THE FLOOR (DRYWALL IS NOT | | CONSIDERED A HARD SURFACE) | | | | 3) DOORS LABELED (11) AND (12) ARE IN A SERIES AND | | REQUIRE MORE SPACE BETWEEN THEM - FBC ACCESSIBILITY | | 404.2.6 DOORS IN SERIES AND GATES IN SERIES. | | THE DISTANCE BETWEEN TWO HINGED OR PIVOTED DOORS IN | | SERIES AND GATES IN SERIES SHALL BE 48 INCHES (1220 MM) | | MINIMUM PLUS THE WIDTH OF DOORS OR GATES SWINGING INTO | | THE SPACE. | | | | 4) PLEASE SHOW THE WALL INSULATION TYPE AND "R" VALUE - | | FBC ENERGY | | | | 5) IN THE PRODUCT APPROVAL PROVIDED FOR THE FLAT DECK | | (FL10284) AND (FL10264) - PLEASE CIRCLE THE ROOFING | | SYSTEM TO BE USED IN THE ROOFING PRODUCT APPROVAL - | | ROOFING SYSTEM TO BE USED ON THE PROVIDED PRODUCT | | APPROVAL MAY REQUIRE ADDITIONAL SIGNED AND SEALED | | ATTACHMENT DETAILS FROM AN ARCHITECT OR ENGINEER FOR | | ROOF WIND ZONES 2 AND 3 WHICH REQUIRE A HIGHER PRESSURE | | THAN THE MAXIMUM SHOWN ON THE PRODUCT APPROVAL - SEE | | GENERAL NOTES IN THE PRODUCT APPROVAL. | | | | 6) ALL PRODUCT APPROVALS NEED TO BE REVIEWED AND MARKED | | APPROVED BY THE DESIGNER OF RECORD OR LISTED ON THE | | DRAWINGS BY THE PRODUCT APPROVAL NUMBER - FBC WPB | | 107.3.4 | | | | 7) THE HIGHER ROOF DOES NOT SHOW THE DECK TYPE - FBC | | 107 | | | | 8) PLEASE SHOW THE WALL SHEATHING ATTACHMENT TYPE, SIZE | | AND ON CENTER SPACING TO METAL FRAMING - FBC 107 | | | | 9) BUILDING CONSTRUCTION TYPE IS SHOWN AS IIB - PLYWOOD | | WALL SHEATHING SHOULD BE SHOWN AS FIRE RETARDANT - FBC | | 603.1 | | | | 10) PLEASE SHOW THE CEILING HEIGHT FOR THE ROOMS | | TOWARDS THE REAR OF THE BUILDING - FBC 1208.2 | | | | 11) ACCESSIBLE RESTROOM = PLEASE USE THE WORDS | | "REFLECTIVE SURFACE" WHEN REFERRING TO THE MIRROR | | HEIGHT FROM THE FLOOR - FBC A 603.3 MIRRORS. | | MIRRORS LOCATED ABOVE LAVATORIES OR COUNTERTOPS SHALL | | BE INSTALLED WITH THE BOTTOM EDGE OF THE REFLECTING | | SURFACE 40 INCHES (1015 MM) MAXIMUM ABOVE THE FINISH | | FLOOR OR GROUND. | | | | 12) EXTERIOR ALUMINUM SIDING IS SUBJECT TO WIND LOADS - | | PLEASE PROVIDE ATTACHMENT DETAILS OR PRODUCT APPROVALS | | - FBC 107 | | | | 13) SEPARATE PERMITS ARE REQUIRED FOR - EXISTING | | BUILDING DEMO., PARKING LOT, SITE WALLS/SCREEN WALLS. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2023-03-15 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2023-03-15 |
Time |
15:47 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2023-03-15 |
Time |
15:36 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2023-01-10 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2023-01-10 |
Time |
14:16 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2023-01-10 |
Time |
14:16 |
Sent To |
|
|
Notes |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
2 |
Status |
N |
Date |
2020-12-20 |
|
|
Cont ID |
|
Sent By |
rrossano |
Date |
2020-12-20 |
Time |
|
Rev Time |
0.00 |
Received By |
rrossano |
Date |
2020-12-20 |
Time |
|
Sent To |
|
|
Notes |
2020-12-31 10:40:46 | DEVELOPER CAN MOVE FORWARD WITH ONSITE DEMO AT RISK. | | ENGINEERING PERMIT WILL NEED TO BE APPLIED FOR. | | | | CALL FOR LOCATES, DIAL 811 BEFORE YOU DIG. FOR MORE | | INFO ON "CALL BEFORE YOU DIG", GO TO | | HTTP://WWW.SUNSHINE811.COM (REF: UNDERGROUND FACILITY | | DAMAGE PREVENTION AND SAFETY ACT, FLORIDA STATUTE, | | CHAPTER 556.) | | | | THANKS, | | RICK ROSSANO, PROJECT COORDINATOR, ENGINEERING SERVICES | | DEPARTMENT | | 401 CLEMATIS STREET, 4TH FLOOR, WEST PALM BEACH, FL | | 33401 | | DIRECT: (561) 494-1098, FAX: (561) 494-1116, MOBILE: | | (561) 246-9525 | | EMAIL: [email protected] | | WWW.WPB.ORG/ENGINEERING | | | 2020-12-20 09:21:35 | UNDER SITE PLAN REVIEW. |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
1 |
Status |
F |
Date |
2020-08-19 |
|
|
Cont ID |
|
Sent By |
rrossano |
Date |
2020-08-19 |
Time |
|
Rev Time |
|
Received By |
rrossano |
Date |
2020-08-19 |
Time |
|
Sent To |
|
|
Notes |
2020-08-19 17:25:42 | UNDER STIE PLAN APPROVAL REVIEW. |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
4 |
Status |
P |
Date |
2023-04-05 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2023-04-05 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2023-04-05 |
Time |
10:50 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2023-03-02 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2023-03-02 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2023-03-02 |
Time |
11:42 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2022-12-20 |
|
|
Cont ID |
|
Sent By |
|
Date |
2022-12-20 |
Time |
|
Rev Time |
|
Received By |
bdolan |
Date |
2022-12-20 |
Time |
11:10 |
Sent To |
|
|
Notes |
2022-12-20 11:11:39 | ANY AND ALL WORK ON THE FIRE ALARM SYSTEM SHALL BE DONE | | BY A FIRE ALARM CONTRACTOR. A SEPARATE SHOP DRAWING | | COMPLIANT WITH NFPA 72 IS REQUIRED TO BE SUBMITTED, | | REVIEWED AND APPROVED BY THE FIRE PREVENTION BUREAU | | PRIOR TO ANY INSTALLATION. | | | | PER CITY CODES, ALL WORK IS SUBJECT TO FIELD | | INSPECTIONS AND APPROVAL. | | | | CAPT. BRIAN DOLAN | | DIVISION OF FIRE PREVENTION | | 561-804-4752 | | [email protected] | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2020-07-31 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2020-07-31 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2020-07-31 |
Time |
16:09 |
Sent To |
|
|
Notes |
2020-07-31 16:12:11 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED | | AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE | | PROVISO COMMENTS WILL RESULT IN A FAILED FIRE | | INSPECTION. | | | | | | 1) ANY AND ALL WORK ON THE FIRE ALARM SYSTEM OR DEVICES | | SHALL BE DONE UNDER SEPARATE PERMIT AND SHOP DRAWINGS. | | | | PLEASE ENSURE COMPLIANCE | | | | | | 2) ANY PROPOSED ACCESS CONTROL SHALL BE INSTALLED UNDER | | A SEPARATE PERMIT AND SHOP DRAWINGS. | | | | PLEASE ENSURE COMPLIANCE | | | | PETER LEDUC | | FIRE MARSHAL | | WEST PALM BEACH FIRE RESCUE | | 561-804-4709 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
7 |
Status |
N |
Date |
2023-06-26 |
|
|
Cont ID |
|
Sent By |
aoliver |
Date |
2023-06-26 |
Time |
09:09 |
Rev Time |
0.00 |
Received By |
aoliver |
Date |
2023-05-22 |
Time |
08:13 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2023-04-20 |
|
|
Cont ID |
|
Sent By |
asangele |
Date |
2023-04-20 |
Time |
09:35 |
Rev Time |
0.00 |
Received By |
asangele |
Date |
2023-04-20 |
Time |
09:35 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2023-03-15 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2023-03-15 |
Time |
15:47 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2023-03-01 |
Time |
08:19 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2023-01-12 |
|
|
Cont ID |
|
Sent By |
asangele |
Date |
2023-01-12 |
Time |
15:01 |
Rev Time |
0.00 |
Received By |
asangele |
Date |
2023-01-12 |
Time |
15:01 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2021-03-04 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2021-03-04 |
Time |
19:43 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2021-02-09 |
Time |
11:10 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2020-12-28 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2020-12-28 |
Time |
11:10 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2020-12-09 |
Time |
15:25 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2020-10-14 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2020-10-14 |
Time |
19:04 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2020-07-30 |
Time |
16:26 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
3 |
Status |
|
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2023-04-19 |
Time |
16:26 |
Sent To |
|
|
Notes |
2023-04-19 16:26:42 | 4/19/23 EMAILED IMPACT OFFICE TO REVIEW. LEM |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
F |
Date |
2023-01-12 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2023-01-12 |
Time |
09:42 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2023-01-12 |
Time |
09:42 |
Sent To |
|
|
Notes |
2023-01-12 09:42:49 | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | | | UPON APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE | | RECEIPT TO YOUR PROJECT OR EMAIL IT TO | | [email protected] . | | |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2021-02-19 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2021-02-19 |
Time |
09:13 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2020-09-16 |
Time |
14:34 |
Sent To |
|
|
Notes |
2021-02-19 09:15:08 | **AFTER BUILDING AND ZONING PASS AUDIT/REVIEW, BUILDING | | REVIEWER IS TO VERIFY THAT THE PLAN THAT IMPACT FEES | | REVIEWED IS THE SAME AS PASSED BY ZONING AND BUILDING | | S.HILL | | | | | | | 2021-02-16 13:10:10 | MU-2020-47056 - $10,841.23 - PAID | 2020-09-16 14:35:03 | 9/16/20 EMAILED IMPACT FEE OFFICE FOR REVIEW. LEM |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
P |
Date |
2023-06-21 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2023-06-21 |
Time |
09:28 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2023-06-21 |
Time |
09:14 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
F |
Date |
2023-04-19 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2023-04-19 |
Time |
16:31 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2023-04-19 |
Time |
16:31 |
Sent To |
|
|
Notes |
2023-04-19 16:36:06 | PROVIDE THE OUTDOOR AIR FOR EACH USE OF SPACE ACCORDING | | TO FMC 403.3.1.1 AND TABLE 403.3.1.1. THE CALCULATIONS | | SUBMITTED FROM ASHRAE SEEM TO BE USING A DIFFERENT | | OCCUPANT COUNT THAN ALLOWED FROM THE 2020 FMC. | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | | | | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2023-03-09 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2023-03-09 |
Time |
16:50 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2023-03-09 |
Time |
16:50 |
Sent To |
|
|
Notes |
2023-03-09 16:50:28 | 2ND REVIEW FMC | | PERMIT: 20071007 | | | | CODES IN EFFECT: 2020 | | | | FBC- FLORIDA BUILDING CODE | | FMC- FLORIDA MECHANICAL CODE | | FEC- FLORIDA ENERGY CONSERVATION | | FGC- FLORIDA FUEL GAS | | FEX- FLORIDA EXISTING BUILDING CODE | | FRC- FLORIDA RESIDENTIAL BUILDING CODE | | F.S.- FLORIDA STATUTES | | FAC- FLORIDA ACCESSIBILITY CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) THE OUTDOOR AIR CALCULATIONS SHALL BE CALCULATED | | BASED ON THE OCCUPANCY CLASSIFICATION AND THE OCCUPANT | | DENSITY FROM FMC TABLE 403.3.1.1 AND NOT THE ARCHITECTS | | EGRESS COUNTS. FMC 403.3.1.1 | | | | 2) SHOW THE REQUIRED DUCT SMOKE DETECTORS FOR THE RTUS | | THAT SHARE SUPPLY AIR. FMC 606.2.2 | | | | 3) PROVIDE THE ACCESS ON THE DRAWING FOR THE SERVICING | | OF THE ROOFTOP UNITS. FMC 306.5 | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM. | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2023-01-03 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2023-01-03 |
Time |
16:04 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2023-01-03 |
Time |
16:04 |
Sent To |
|
|
Notes |
2023-01-03 16:04:47 | 1ST REVIEW FMC | | PERMIT: 20071007 | | | | CODES IN EFFECT: 2020 | | | | FBC- FLORIDA BUILDING CODE | | FMC- FLORIDA MECHANICAL CODE | | FEC- FLORIDA ENERGY CONSERVATION | | FGC- FLORIDA FUEL GAS | | FEX- FLORIDA EXISTING BUILDING CODE | | FRC- FLORIDA RESIDENTIAL BUILDING CODE | | F.S.- FLORIDA STATUTES | | FAC- FLORIDA ACCESSIBILITY CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) PROVIDE THE OUTDOOR AIR CALCULATIONS BASED ON THE | | OCCUPANCY CLASSIFICATION THAT MOST CLOSELY RESEMBLES | | THE USE OF EACH SPACE FROM FMC TABLE 403.3.1.1. FMC | | 403.3.1.1 | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM. | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2023-04-10 |
|
|
Cont ID |
|
Sent By |
rwbrown |
Date |
2023-04-10 |
Time |
09:39 |
Rev Time |
0.00 |
Received By |
rwbrown |
Date |
2023-04-10 |
Time |
09:39 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2023-03-02 |
|
|
Cont ID |
|
Sent By |
rwbrown |
Date |
2023-03-02 |
Time |
14:03 |
Rev Time |
0.00 |
Received By |
rwbrown |
Date |
2023-03-02 |
Time |
14:03 |
Sent To |
|
|
Notes |
2023-03-02 14:07:20 | 2ND PLUMBING REVIEW | | | | THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED | | BY RYAN BROWN WITH THE FOLLOWING COMMENTS. | | | | COMMENT NOT ADDRESSED - THIS COMMENT IS NOT FOR PUBLIC | | HAND WASHING REQUIREMENTS. THIS COMMENT IS FOR HOT | | WATER. A THERMOSTATIC MIXING VALVE NEEDS TO BE AT THE | | WATER HEATER FOR HOT WATER SUPPLY, NOT TEMPERED WATER | | DELIVERY. THE WATER HEATER DETAIL NEEDS TO SHOW A | | MIXING VALVE. | | 1. 2020 FPC 607.1.1 - HOT WATER DELIVERY - PER THIS | | SECTION, THE THERMOSTAT ON THE WATER HEATER CANNOT | | SERVE AS THE LIMITING DEVICE FOR HOT OR TEMPERED WATER | | DELIVERY. A MIXING DEVICE MUST LIMIT THE TEMPERATURE. | | THE DEVICE MUST COMPLY WITH ASSE 1017 AND MUST BE | | INSTALLED AT THE HOT WATER SOURCE PER 2020 FPC 613.1. | | THIS IS IN ADDITION TO THE REQUIREMENTS FOR PUBLIC | | HANDWASHING PROTECTION FOR TEMPERED WATER. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM. | | | | | | RYAN W. BROWN | | CHIEF PLUMBING INSPECTOR | | OFFICE: 561-805-6692 | | CELL: 561-517-4293 | | EMAIL: [email protected] | | | | | | V7 FPC - 2020 FLORIDA PLUMBING CODE | | V7 FGC - 2020 FLORIDA FUEL GAS | | V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE | | V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE | | V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE | | V7 FEC - 2020 FLORIDA ENERGY CONSERVATION | | 2021 F.S. - 2021 FLORIDA STATUTES | | 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE | | 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE | | FBC CHAPTER 1 | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2023-01-05 |
|
|
Cont ID |
|
Sent By |
rwbrown |
Date |
2023-01-05 |
Time |
14:31 |
Rev Time |
0.00 |
Received By |
rwbrown |
Date |
2023-01-05 |
Time |
14:31 |
Sent To |
|
|
Notes |
2023-01-05 14:31:46 | 1ST PLUMBING REVIEW | | | | THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED | | BY RYAN BROWN WITH THE FOLLOWING COMMENTS. | | | | 1. 2020 FPC 607.1.1 - HOT WATER DELIVERY - PER THIS | | SECTION, THE THERMOSTAT ON THE WATER HEATER CANNOT | | SERVE AS THE LIMITING DEVICE FOR HOT OR TEMPERED WATER | | DELIVERY. A MIXING DEVICE MUST LIMIT THE TEMPERATURE. | | THE DEVICE MUST COMPLY WITH ASSE 1017 AND MUST BE | | INSTALLED AT THE HOT WATER SOURCE PER 2020 FPC 613.1. | | THIS IS IN ADDITION TO THE REQUIREMENTS FOR PUBLIC | | HANDWASHING PROTECTION FOR TEMPERED WATER. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM. | | | | | | RYAN W. BROWN | | CHIEF PLUMBING INSPECTOR | | OFFICE: 561-805-6692 | | CELL: 561-517-4293 | | EMAIL: [email protected] | | | | | | V7 FPC - 2020 FLORIDA PLUMBING CODE | | V7 FGC - 2020 FLORIDA FUEL GAS | | V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE | | V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE | | V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE | | V7 FEC - 2020 FLORIDA ENERGY CONSERVATION | | 2021 F.S. - 2021 FLORIDA STATUTES | | 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE | | 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE | | FBC CHAPTER 1 | | |
|
|
Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
Rev No |
4 |
Status |
N |
Date |
2022-11-17 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2022-11-17 |
Time |
18:52 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2022-11-17 |
Time |
18:52 |
Sent To |
|
|
Notes |
2022-11-17 18:52:46 | PRIVATE PROVIDER RESCINDED | | |
|
|
Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
Rev No |
3 |
Status |
F |
Date |
2021-02-16 |
|
|
Cont ID |
|
Sent By |
rgathrig |
Date |
2021-02-16 |
Time |
17:15 |
Rev Time |
0.00 |
Received By |
rgathrig |
Date |
2021-02-16 |
Time |
17:14 |
Sent To |
|
|
Notes |
2021-02-16 17:15:25 | | | | | | | PRIVATE PROVIDER REVIEW NOT APPROVED | | | | ZONING, ENGINEERING AND IMPACT FEE OFFICE STILL NEED TO | | STILL SIGN OFF BEFORE THE PLANS ARE CONSIDERED A | | COMPLETE PERMIT PACKAGE. | | | | THE CERTIFICATE OF INSURANCE FROM THE PRIVATE PROVIDER | | DOES NOT STATE THERE IS PROFESSIONAL LIABILITY | | INSURANCE IN PLACE FOR THE SERVICES OF DOING PRIVATE | | PROVIDER PLAN REVIEW. | | | | AFFIDAVIT FOR CODE COMPLIANCE FOR PLAN REVIEW APPEAR TO | | LIST ALL THE PAGES BUT ARE SUBMITTED EARLY BECAUSE | | THERE HAS NOT BEEN A PLAN REVIEW AUDIT YET. IF ANY | | COMMENTS ARE CREATED FROM THE PLAN REVIEW AUDIT, NEW | | CODE COMPLIANCE AFFIDAVITS WILL BE REQUIRED | | | | RICHARD GATHRIGHT | | ABO | | 561 805 6679 | | | | |
|
|
Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
Rev No |
2 |
Status |
F |
Date |
2020-12-28 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2020-12-28 |
Time |
11:10 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2020-12-28 |
Time |
11:10 |
Sent To |
|
|
Notes |
2020-12-28 11:10:30 | PRIVATE PROVIDER REVIEW NOT APPROVED | | | | THIS SUBMITTAL IS NOT COMPLETE BECAUSE THE PROJECT HAS | | NOT BEEN APPROVED BY OTHER AGENCIES FIRST BEFORE BEING | | SENT TO THE BUILDING DEPARTMENT | | | | RICHARD GATHRIGHT | | ABO | | 561-805-6679 | | | | |
|
|
Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
Rev No |
1 |
Status |
F |
Date |
2020-10-15 |
|
|
Cont ID |
|
Sent By |
rgathrig |
Date |
2020-10-15 |
Time |
16:01 |
Rev Time |
0.00 |
Received By |
rgathrig |
Date |
2020-10-15 |
Time |
16:01 |
Sent To |
|
|
Notes |
2020-10-15 16:01:15 | PRIVATE PROVIDER REVIEW NOT APPROVED | | | | THIS SUBMITTAL IS NOT COMPLETE BECAUSE THE PROJECT HAS | | NOT BEEN APPROVED BY OTHER AGENCIES FIRST BEFORE BEING | | SENT TO THE BUILDING DEPARTMENT | | | | RICHARD GATHRIGHT | | ABO | | 561-805-6679 | | | | |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
3 |
Status |
P |
Date |
2023-04-05 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2023-04-05 |
Time |
10:04 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2023-04-05 |
Time |
10:04 |
Sent To |
|
|
Notes |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
2 |
Status |
F |
Date |
2023-03-08 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2023-03-08 |
Time |
08:12 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2023-03-08 |
Time |
08:12 |
Sent To |
|
|
Notes |
2023-03-08 08:13:41 | SEE BUILDING PLAN REVIEW |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
F |
Date |
2023-01-12 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2023-01-12 |
Time |
09:46 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2023-01-12 |
Time |
09:46 |
Sent To |
|
|
Notes |
2023-01-12 09:46:35 | SEE BUILDING PLAN REVIEW |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
4 |
Status |
P |
Date |
2023-06-21 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2023-06-21 |
Time |
09:28 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2023-06-21 |
Time |
09:28 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
P |
Date |
2023-04-05 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2023-04-05 |
Time |
10:12 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2023-04-05 |
Time |
10:12 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2023-03-08 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2023-03-08 |
Time |
08:22 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2023-03-08 |
Time |
08:22 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2023-01-10 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2023-01-10 |
Time |
14:18 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2023-01-10 |
Time |
14:16 |
Sent To |
|
|
Notes |
2023-01-10 14:19:20 | ALL PLANS PASSED SIGNATURE REVIEW | 2023-01-03 16:05:32 | MECHANICAL DIGITAL SIGNATURES APPROVED ME |
|
|
Review Stop |
Z |
ZONING |
Rev No |
8 |
Status |
F |
Date |
2023-06-05 |
|
|
Cont ID |
|
Sent By |
asangele |
Date |
2023-06-05 |
Time |
11:45 |
Rev Time |
0.00 |
Received By |
asangele |
Date |
2023-06-05 |
Time |
11:45 |
Sent To |
|
|
Notes |
2023-06-05 11:46:26 | 6/5/2023 | | FAILED | | | | MINOR SITE PLAN AMENDMENT IS REQUIRED | | | | | | ALEXIS SANGELEER | | PLANNER | | [email protected] |
|
|
Review Stop |
Z |
ZONING |
Rev No |
7 |
Status |
F |
Date |
2023-04-20 |
|
|
Cont ID |
|
Sent By |
ASangele |
Date |
2023-04-20 |
Time |
09:35 |
Rev Time |
0.00 |
Received By |
asangele |
Date |
2023-04-20 |
Time |
09:35 |
Sent To |
|
|
Notes |
2023-04-20 09:46:46 | FAILED | | 4/20/2023 | | | | A MINOR SITE PLAN AMENDMENT IS REQUIRED. | | | | PARKING AND DRIVEWAY ENTERANCE HAS CHANGED THERE ALSO | | WAS A LOSS OF A PARKING SPOT PARKING TABLE NEEDS TO | | REFLECT THE CORRECT NUMBER OF PARKING LOCATED ON THE | | PROPERTY. | | | | COUNTY LETTER ALLOWING THE BELEVDERE ENTERANCE AS | | STATED IN THE CONTIONAL APPROVAL LETTER. | | | | | | ALEXIS SANGELEER | | PLANNER | | [email protected] |
|
|
Review Stop |
Z |
ZONING |
Rev No |
6 |
Status |
P |
Date |
2023-03-23 |
|
|
Cont ID |
|
Sent By |
asangele |
Date |
2023-03-23 |
Time |
08:48 |
Rev Time |
0.00 |
Received By |
asangele |
Date |
2023-03-23 |
Time |
08:48 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
5 |
Status |
F |
Date |
2023-03-09 |
|
|
Cont ID |
|
Sent By |
LLouie |
Date |
2023-03-09 |
Time |
10:05 |
Rev Time |
0.00 |
Received By |
kdefranc |
Date |
2023-03-09 |
Time |
10:03 |
Sent To |
|
|
Notes |
2023-03-09 10:05:12 | 3/9/23 ??? FAILED | | | | REVIEW COMMENT TO BE ADDRESSED: | | 1. THIS PROJECT NO LONGER HAS SITE PLAN APPROVAL. THE | | EXTENSION REQUEST APPROVAL EXPIRED JUNE 7, 2022. | | | | | | KEVIE DEFRANC | | SENIOR PLANNER ??? PLANNING DIVISION | | [email protected] | | 561-822-1449 | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
4 |
Status |
F |
Date |
2023-01-12 |
|
|
Cont ID |
|
Sent By |
asangele |
Date |
2023-01-12 |
Time |
14:59 |
Rev Time |
0.00 |
Received By |
asangele |
Date |
2023-01-12 |
Time |
14:59 |
Sent To |
|
|
Notes |
2023-01-12 15:01:17 | 1/12/2023 | | FAILED | | | | THIS PROJECT NO LONGER HAS SITE PLAN APPROVAL | | EXPIRED JUNE 7,2022 | | | | ALEXIS SANGELEER | | PLANNER | | [email protected] | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
F |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2021-03-04 |
Time |
|
Rev Time |
0.00 |
Received By |
|
Date |
2021-03-04 |
Time |
|
Sent To |
|
|
Notes |
2021-03-04 11:30:33 | *************ZONING REVIEW*************** | | | | SUBMITTED SITE PLAN IS FINE. | | | | ACCORDING TO YOUR SITE PLAN APPROVAL LETTER THE | | APPROVAL IS SUBJECT TO THE FOLLOWING CONDTIONS: | | | | 1. NO NEW DRAINAGE STRUCTURES ARE TO BE LOCATED WITHIN | | THE PROPOSED RIGHT-OF-WAY. | | 2. THE ENGINEERING PLANS AND SURVEY SHALL REFERENCE THE | | SAME VERTICAL DATUM. | | 3. PROVIDE COUNTY LETTER/APPROVAL PERTAINING TO THE | | BELVEDERE DRIVEWAY LOCATION AND CONFIGURATION. | | 4. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | SUBMITTED, REVIEWED, AND APPROVED BY THE DEVELOPMENT | | SERVICES DEPARTMENT, PLANNING DIVISION. | | | | | | PROVIDE DOCUMENTATION FOR #3. | | | | ALANA WOOTEN | | PLANNER | | PLANNING DIVISON | | 561-822-1449 | | [email protected] |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2020-12-22 |
|
|
Cont ID |
|
Sent By |
awooten |
Date |
2020-12-22 |
Time |
|
Rev Time |
0.00 |
Received By |
awooten |
Date |
2020-12-22 |
Time |
|
Sent To |
|
|
Notes |
2020-12-22 10:34:34 | ****************************ZONING REVIEW | | FAILED*********************************** | | | | SUBMIT THE APPROVED SITE PLAN. THE SITE PLAN SUBMITTED | | DOES NOT MATCH WHAT WAS APPROVED. | | | | ALANA WOOTEN | | PLANNER | | PLANNING DIVISION | | 561-822-1449 | | [email protected] |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2020-10-02 |
|
|
Cont ID |
|
Sent By |
awooten |
Date |
2020-10-02 |
Time |
|
Rev Time |
|
Received By |
awooten |
Date |
2020-10-02 |
Time |
|
Sent To |
|
|
Notes |
2020-10-02 12:59:22 | ************ZONING REVIEW FAILED************** | | | | THE 40 FT X 40 FT DEDICATION TO THE COUNTY AT THE | | CORNER OF PARKER AND BELVEDERE WILL AFFECT THE BUILDING | | SETBACKS. INDICATE THE NEW SETBACKS, CONSIDERING THE | | DEDICATION. | | | | REPLAT REQUIRED AS A CONDITION OF CO. | | | | SUBMIT SITE PLAN APPROVAL LETTER AND APPROVED SITE | | PLAN. | | | | | | ALANA WOOTEN | | PLANNER | | PLANNING DIVISION | | 561-822-1449 | | [email protected] | | |
|
|