Plan Review Details - Permit 20070965
Plan Review Stops For Permit 20070965
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2020-10-13 Cont ID  
Sent By jwitmer Date 2020-10-13 Time 09:14 Rev Time 0.00
Received By jwitmer Date 2020-10-13 Time 08:58 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2020-10-04 Cont ID  
Sent By jwitmer Date 2020-10-04 Time 09:44 Rev Time 0.00
Received By jwitmer Date 2020-10-04 Time 08:53 Sent To  
Notes
2020-10-04 09:43:27WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2017 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 20070965
 ADD: 1101 GREEN PINE BLVD. # H-1
 CONT: WINDOW WORLD
 TEL: 561-684-2040
 E-MAIL: [email protected]
  
 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 3RD REVIEW
 DATE: SUN. OCT. 04TH/ 2020
 ACTION: DENIED
  
 1) THE 2 DRAWINGS IN THE DRAWINGS FOLDER, THE SKETCH OF
 THE BUILDING W/ OPENING LOCATIONS AND THE WIND DESIGN
 CRITERIA AND 5 OPENING SIZES OF THE BUILDING. WHAT THE
 CONTRACTOR (QUALIFIER/ CERTIFICATE HOLDER) NEEDS TO DO
 IS TAKE OWNERSHIP OF THESE PLANS BY PRINTING THEIR
 NAME, SIGNING THEIR NAME AND LICENSE NUMBER TO EACH OF
 THE PLANS.
  
 CERTIFICATION BY CONTRACTOR.
 107.3.4.3 CERTIFICATION BY CONTRACTOR. PLEASE NOTE THE
 EXCEPTION TO ENGINEERED PLANS UNDER 471.003(H)
 ELECTRICAL/ PLUMBING/ MECHANICAL, 481.229(1)(C)
 (BUILDING) REQUIRES THE CONTRACTOR FOR THAT TRADE THAT
 WILL BE LICENSED IN THAT TRADE, WILL ALSO BE THE
 CONTRACTOR THAT DESIGNS THE SYSTEM UNDER THAT TRADE.
 THE CONTRACTOR (QUALIFIER) THAT CREATED / DRAWN THE SET
 OF PLANS WILL NEED TO IDENTIFY THEMSELVES AS THE AUTHOR
 OF THE PLANS. PLEASE PRINT YOUR NAME, SIGN YOUR NAME
 AND LICENSE NUMBER FOR THE TRADE YOU ARE LICENSED IN
 AND PLANS DRAWN.
  
 2) PLEASE NOTE FOR FUTURE USE OF PROJECT DOX, PLEASE DO
 NOT LOAD THE WIND DESIGN CHARTS THAT ARE A DESIGN FROM
 AN ENGINEER INTO THE DOCUMENT FOLDER, LOAD ANY
 ENGINEERED DOCUMENTS INTO THE DRAWING FILE
 INDIVIDUALLY. ENGINEERED WIND LOAD CHARTS CANNOT BE
 VERIFIED THEY ARE ELECTRONICALLY SIGNED AND SEALED
 DOCUMENTS WHEN IN THE SUPPORTING DOCUMENT FOLDER.
 FLORIDA ADMINISTRATIVE CODE 61G15-23.005 (3)(C) A
 DOCUMENT IN THE FILE FOLDER, SCANNED, FACSIMILE,
 DIGITALLY CREATED OR COPIED IMAGE OF THE LICENSEE?S
 SIGNATURE SHALL NOT BE USED ON DIGITALLY SIGNED AND
 SEALED ENGINEERING PLANS, SPECIFICATIONS, REPORTS OR
 OTHER DOCUMENTS.
  
 3) THE SUBMITTED FLORIDA APPROVAL # 1850-R11CHARTS ARE
 ILLEGIBLE, 107.2.1.3. QUALITY OF PLANS. BUILDING PLANS
 SHALL BE DRAWN TO A 1/8TH INCH SCALE ON SUBSTANTIAL
 PAPER OR OTHER ACCEPTABLE MEDIUM. THE BUILDING OFFICIAL
 MAY ESTABLISH THROUGH DEPARTMENT POLICY OTHER STANDARDS
 FOR THE PLANS AND SPECIFICATIONS IN ORDER TO PROVIDE
 CONFORMITY TO ITS RECORD RETENTION PROGRAM. THIS POLICY
 MAY INCLUDE SUCH THINGS AS MINIMUM SIZE, SHAPE,
 CONTRAST, CLARITY, OR OTHER ITEMS RELATED TO RECORD
 MANAGEMENT. ELECTRONIC MEDIA MUST BE COMPATIBLE WITH
 THE ARCHIVE REQUIREMENTS OF FLORIDA STATUTES.
  
 4) I APOLOGIES FOR THERE NOT BEING NOTES IN THE 1ST
 REVIEW. I HAVE MY CELL NUMBER ON ALL REVIEWS, IF I
 CAN?T ANSWER THE PHONE PLEASE LEAVE A MESSAGE SO I CAN
 GET BACK TO YOU QUICKLY. A TRANSMITTAL LETTER LISTING
 THE ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION
 OF THE REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR
 ANTICIPATED COOPERATION.
  
 PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS
 REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT
 REVIEW CYCLE.
  
 PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID
 19
 IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS
 561-718-9724.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2020-09-17 Cont ID  
Sent By rmcdouga Date 2020-09-17 Time 15:58 Rev Time 0.00
Received By rmcdouga Date 2020-09-17 Time 15:58 Sent To  
Notes
2020-09-17 16:06:11PLAN REVIEW COMMENTS
  
 1ST REVIEW: FBC SIXTH EDITION (2017)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) THE PRODUCT APPROVALS FOR THE BERTHA ACCORDION
 SHUTTERS ARE ILLEGIBLE. I CAN NOT SEE THE ANCHOR
 SPACING TABLES THEY ARE NOT LEGIBLE. UPLOAD CLEAR
 COPIES OF THE PRODUCT APPROVAL. FBC 107.2.1
  
 2) THE WINDLOAD CALCULATIONS THAT WERE UPLOADED ARE
 COPIES FROM AND ENGINEER. WHEN YOU SUBMIT DOCUMENTS
 FROM AN ENGINEER THEY ARE REQUIRED TO HAVE THE
 ENGINEER'S ORIGINAL HANDWRITTEN SIGNATURE IF PAPER AND
 HIS DIGITAL SIGNATURE IF ELECTRONICALLY SUBMITTED. FS
 471 AND FAC 61G-15

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-08-17 Cont ID  
Sent By jwitmer Date 2020-08-17 Time 19:46 Rev Time 0.00
Received By jwitmer Date 2020-08-17 Time 19:26 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date   Cont ID  
Sent By   Date 2020-10-13 Time 09:14 Rev Time 0.00
Received By lmarchan Date 2020-10-08 Time 16:06 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2020-10-04 Cont ID  
Sent By jwitmer Date 2020-10-04 Time 09:46 Rev Time 0.00
Received By jwitmer Date 2020-09-30 Time 14:33 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-09-17 Cont ID  
Sent By rmcdouga Date 2020-09-17 Time 15:59 Rev Time 0.00
Received By rmcdouga Date 2020-09-10 Time 11:51 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2020-08-17 Time   Rev Time 0.00
Received By lmarchan Date 2020-08-04 Time 14:07 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 4 Status P Date 2020-10-13 Cont ID  
Sent By jwitmer Date 2020-10-13 Time 09:14 Rev Time 0.00
Received By jwitmer Date 2020-10-13 Time 08:59 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status F Date 2020-10-04 Cont ID  
Sent By jwitmer Date 2020-10-04 Time 09:45 Rev Time 0.00
Received By jwitmer Date 2020-10-04 Time 08:54 Sent To  
Notes
2020-10-04 09:45:18WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2017 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 20070965
 ADD: 1101 GREEN PINE BLVD. # H-1
 CONT: WINDOW WORLD
 TEL: 561-684-2040
 E-MAIL: [email protected]
  
 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 3RD REVIEW
 DATE: SUN. OCT. 04TH/ 2020
 ACTION: DENIED
  
 1) THE 2 DRAWINGS IN THE DRAWINGS FOLDER, THE SKETCH OF
 THE BUILDING W/ OPENING LOCATIONS AND THE WIND DESIGN
 CRITERIA AND 5 OPENING SIZES OF THE BUILDING. WHAT THE
 CONTRACTOR (QUALIFIER/ CERTIFICATE HOLDER) NEEDS TO DO
 IS TAKE OWNERSHIP OF THESE PLANS BY PRINTING THEIR
 NAME, SIGNING THEIR NAME AND LICENSE NUMBER TO EACH OF
 THE PLANS.
  
 CERTIFICATION BY CONTRACTOR.
 107.3.4.3 CERTIFICATION BY CONTRACTOR. PLEASE NOTE THE
 EXCEPTION TO ENGINEERED PLANS UNDER 471.003(H)
 ELECTRICAL/ PLUMBING/ MECHANICAL, 481.229(1)(C)
 (BUILDING) REQUIRES THE CONTRACTOR FOR THAT TRADE THAT
 WILL BE LICENSED IN THAT TRADE, WILL ALSO BE THE
 CONTRACTOR THAT DESIGNS THE SYSTEM UNDER THAT TRADE.
 THE CONTRACTOR (QUALIFIER) THAT CREATED / DRAWN THE SET
 OF PLANS WILL NEED TO IDENTIFY THEMSELVES AS THE AUTHOR
 OF THE PLANS. PLEASE PRINT YOUR NAME, SIGN YOUR NAME
 AND LICENSE NUMBER FOR THE TRADE YOU ARE LICENSED IN
 AND PLANS DRAWN.
  
  
 PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID
 19
 IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS
 561-718-9724.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2020-09-17 Cont ID  
Sent By rmcdouga Date 2020-09-17 Time 15:58 Rev Time 0.00
Received By rmcdouga Date 2020-09-17 Time 15:58 Sent To  
Notes
2020-09-17 16:08:14SEE BUILDING COMMENT NUMBER 2. ELECTRONICALLY SUBMITTED
 DRAWINGS ARE REQUIRED TO HAVE THE ENGINEER'S DIGITAL
 SIGNATURE ON THEM. YOU ALSO HAVE THE OPTION TO SUBMIT
 THE SIGNED AND SEALED PAPER VERSION OF DRAWINGS. AFTER
 THE ELECTRONIC PLANS HAVE BEEN APPROVED, YOU CAN SUBMIT
 THE CORRESPONDING PAPER DRAWINGS AT THE BUILDING
 DEPARTMENT TO BE VERIFIED. THE ENGINEER'S ORIGINAL
 HANDWRITTEN SIGNATURE AND SEAL IS REQUIRED TO BE ON THE
 DRAWINGS. NO PHOTOCOPY OR OTHER FACSIMILES OF THE
 SIGNATURE ARE ACCEPTABLE. FS 471 & 61G15

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2020-08-17 Cont ID  
Sent By jwitmer Date 2020-08-17 Time 19:46 Rev Time 0.00
Received By jwitmer Date 2020-08-17 Time 19:26 Sent To  
Notes
2020-08-17 19:47:16SEE BUILDING REVIEW.