Plan Review Details - Permit 20070964
Plan Review Stops For Permit 20070964
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2020-09-12 Cont ID  
Sent By pvalenti Date 2020-09-12 Time 11:44 Rev Time 0.00
Received By pvalenti Date 2020-09-12 Time 10:45 Sent To  
Notes
2020-09-12 11:42:53PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
 FBC M = FBC MECHANICAL
 FBC FG = FBC FUEL GAS
  
 BUILDING REVIEW APPROVED WITH PROVISOS:
  
 PRIOR TO INSPECTION PROVIDE ALL DESIGNER OF RECORD
 APPROVED & SPECIALTY ENGINEER SIGNED/SEALED SHOP
 DRAWINGS THAT ARE REQUIRED, INCLUDING STAIR AND RAILING
 SPECIFICATIONS.
  
 ALL WORK SUBJECT TO CITY CODES IS SUBJECT TO FIELD
 INSPECTOR'S APPROVAL.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-07-28 Cont ID  
Sent By pvalenti Date 2020-07-28 Time 14:27 Rev Time 0.00
Received By pvalenti Date 2020-07-28 Time 10:20 Sent To  
Notes
2020-07-28 14:41:42PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
 FBC M = FBC MECHANICAL
  
 BUILDING REVIEW DENIED:
  
 FBC B 107.2.1,:
  
 1) PROVIDE ENGINEER'S LETTER, WITH CALCULATIONS,
 CONFIRMING THAT THE EXISTING FRAMING MEMBERS DESIGN AND
 CONDITION WILL SUPPORT ALL OF THE REQUIRED LOADS.
 2) PROVIDE THE SPAN AND SPACING FOR THE SUPPORTING
 2"X4" REMAINING JOISTS.
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-09-12 Cont ID  
Sent By pvalenti Date 2020-09-12 Time 11:44 Rev Time 0.00
Received By pvalenti Date 2020-08-18 Time 14:47 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-07-28 Cont ID  
Sent By pvalenti Date 2020-07-28 Time 14:48 Rev Time 0.00
Received By pvalenti Date 2020-07-21 Time 15:38 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2020-09-12 Cont ID  
Sent By pvalenti Date 2020-09-12 Time 11:43 Rev Time 0.00
Received By pvalenti Date 2020-09-12 Time 10:45 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2020-07-28 Cont ID  
Sent By pvalenti Date 2020-07-28 Time 14:41 Rev Time 0.00
Received By pvalenti Date 2020-07-28 Time 10:21 Sent To  
Notes
2020-07-28 14:47:05PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
 FBC M = FBC MECHANICAL
  
 ROOFING REVIEW DENIED:
  
 FBC B 107.2, PLEASE PROVIDE ALL ROOFING MATERIAL
 PRODUCT APPROVALS. IDENTIFY SYSTEM, FASTENER TYPE AND
 SPACING PATTERNS FOR ALL ROOF ZONES WITHIN PRODUCT
 APPROVALS.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2020-09-12 Cont ID  
Sent By pvalenti Date 2020-09-12 Time 11:44 Rev Time 0.00
Received By pvalenti Date 2020-09-12 Time 11:44 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2020-07-28 Cont ID  
Sent By pvalenti Date 2020-07-28 Time 14:47 Rev Time 0.00
Received By pvalenti Date 2020-07-28 Time 10:21 Sent To  
Notes
***NONE***