Plan Review Details - Permit 20070913
Plan Review Stops For Permit 20070913
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2020-08-21 Cont ID  
Sent By shill Date 2020-08-21 Time 16:38 Rev Time 0.00
Received By shill Date 2020-08-21 Time 16:38 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2020-08-27 Cont ID  
Sent By cthroop Date 2020-08-27 Time 16:55 Rev Time 0.00
Received By cthroop Date 2020-08-27 Time 16:36 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 3 Status P Date 2020-09-24 Cont ID  
Sent By medwards Date 2020-09-24 Time 12:09 Rev Time 0.00
Received By medwards Date 2020-09-24 Time 12:09 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 2 Status F Date 2020-09-22 Cont ID  
Sent By medwards Date 2020-09-22 Time 14:22 Rev Time 0.00
Received By medwards Date 2020-09-22 Time 14:03 Sent To  
Notes
2020-09-22 14:22:392ND REVIEW FBC-2017 MECHANICAL
 PERMIT- 20070913
  
 CODES IN EFFECT:
  
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH
 EDITION 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) ACCORDING TO TABLE 402.4(3) OF THE FBC FG THE
 EXISTING 1 INCH GALV. RISER IS NOT SIZED TO SUPPLY THE
 NEW COMBINED LOAD OF 691,000 BTU?S, THE 1 INCH GALV.
 SIZED BY THE LONGEST LENGTH METHOD AND USING THE WATER
 HEATER DISTANCE AS THE MOST REMOTE APPLIANCE FROM THE
 METER (60 FEET) THE 1 INCH GALV WILL ONLY SUPPLY
 678,000 BTU?S. PLEASE CORRECT THIS.
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD
 SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER
 SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN
 THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS
 PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS
 PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR
 UPDATED.
  
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2020-08-27 Cont ID  
Sent By medwards Date 2020-08-27 Time 12:19 Rev Time 0.00
Received By medwards Date 2020-08-27 Time 11:20 Sent To  
Notes
2020-08-27 12:19:421ST REVIEW FBC-2017 MECHANICAL
 PERMIT-20070913
  
 CODES IN EFFECT:
  
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH
 EDITION 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) PLEASE PROVIDE THE DISTANCE TO THE MOST REMOTE
 APPLIANCE ON THE GAS DRAWING. FBC FS 107.2.1
  
 2) ON THE GAS DRAWING IT INDICATES THAT THE MAXIMUM BTU
 LOAD IS 457,000. 327,000+40,000+40,000= 407,000, IS
 THERE AN ADDITION APPLIANCE THAT ISN?T ACCOUNTED FOR?
 FBC FS 107.2.1-20070913
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD
 SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER
 SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN
 THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS
 PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS
 PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR
 UPDATED.
  
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-10-01 Cont ID  
Sent By medwards Date 2020-10-01 Time 15:53 Rev Time 0.00
Received By medwards Date 2020-09-17 Time 08:43 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-09-15 Cont ID  
Sent By shill Date 2020-09-15 Time 14:56 Rev Time 0.00
Received By shill Date 2020-08-18 Time 15:10 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status N Date 2020-09-22 Cont ID  
Sent By medwards Date 2020-09-22 Time 14:23 Rev Time 0.00
Received By medwards Date 2020-09-22 Time 14:23 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status N Date 2020-08-27 Cont ID  
Sent By medwards Date 2020-08-27 Time 12:20 Rev Time 0.00
Received By medwards Date 2020-08-27 Time 12:20 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2020-10-01 Cont ID  
Sent By medwards Date 2020-10-01 Time 15:52 Rev Time 0.00
Received By medwards Date 2020-10-01 Time 15:52 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2020-09-22 Cont ID  
Sent By medwards Date 2020-09-22 Time 14:24 Rev Time 0.00
Received By medwards Date 2020-09-22 Time 14:23 Sent To  
Notes
2020-09-22 14:26:08PLEASE PROVIDE ADDRESS OF PROJECT ON THE DRAWING. THE
 DESIGNER OF DRAWING MUST PROVIDE A SIGNATURE ON THE
 DRAWING.
  
 PER THE WPB AMENDMENTS TO THE FBC, EACH SHEET OF PLAN
 (INCLUDING THE SUPPORTING DOCUMENTS) IS REQUIRED TO BE
 SIGNED AND SEALED BY THE PERSON RESPONSIBLE FOR THE
 DESIGN. A DIGITAL PLAN REQUIRES A DIGITAL SIGNATURE
 WITH THE PROPER THIRD PARTY VERIFICATION. PROVIDE
 CORRECTION. ALTERNATIVELY, A SIGNED/SEALED PAPER SET
 MAY BE SUPPLIED TO THE BUILDING DEPARTMENT WHEN ALL
 TRADES ARE APPROVED. WPB FBC 107.1; FS 471/481
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2020-08-21 Cont ID  
Sent By shill Date 2020-08-21 Time 16:39 Rev Time 0.00
Received By shill Date 2020-08-21 Time 16:39 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2020-09-29 Cont ID  
Sent By rthermid Date 2020-09-29 Time   Rev Time 0.00
Received By rthermid Date 2020-09-29 Time   Sent To I
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2020-09-01 Cont ID  
Sent By rthermid Date 2020-09-01 Time   Rev Time  
Received By rthermid Date 2020-09-01 Time   Sent To I
Notes
2020-09-01 11:26:57ZONING PLAN REVIEW
 ________________________________________
  
 DATE OF REVIEW: 9/1/2020
 ________________________________________
  
 REVIEW STATUS: FAILED
 ________________________________________
 PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN
 REVIEW COMMENTS:
  
 1. THE PROPOSED GENERATOR DOES NOT MEET THE SIDE
 SETBACK REQUIREMENT. PURSUANT THE CITY OF WEST PALM
 BEACH ZONING AND LAND DEVELOPMENT REGULATIONS (ZLDR),
 SECTION 94-305(B)(4): MECHANICAL EQUIPMENT MAY NOT
 PROJECT MORE THAN 4 FEET INTO A REQUIRED SETBACK. THE
 REQUIRED SETBACK IS 8 FEET, THE GENERATOR MUST BE
 SETBACK A MINIMUM OF 4 FEET FROM THE PROPERTY LINE.
 ________________________________________
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 IF YOU SUBMITTED A PAPER APPLICATION, AND YOU WOULD
 LIKE TO RESUBMIT ELECTRONICALY, EMAIL
 [email protected] AND REQUEST TO HAVE YOUR
 PROJECT CONVERTED TO PROJECTDOX. YOU WILL RECEIVE LOGIN
 INFORMATION AND A LINK TO UPLOAD YOUR RESUBMITTAL.
 PLEASE BE SURE TO ?COMPLETE THE UPLOAD TASK? WHEN YOU
 ARE FINISHED UPLOADING.
  
 ________________________________________
  
 QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING:
  
 RAFAELA THERMIDOR, ASSOCIATE PLANNER
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION
 401 CLEMATIS STREET - P.O. BOX 3147
 WEST PALM BEACH, FLORIDA 33402
  
 TTY: 800.955.8771
 E: [email protected]
 W: WPB.ORG
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved