Plan Review Details - Permit 20070907
Plan Review Stops For Permit 20070907
Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2020-10-05 Cont ID  
Sent By cthroop Date 2020-10-05 Time 07:48 Rev Time 0.00
Received By cthroop Date 2020-10-03 Time 07:01 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status F Date 2020-09-17 Cont ID  
Sent By cthroop Date 2020-09-17 Time 13:52 Rev Time 0.00
Received By cthroop Date 2020-09-17 Time 13:14 Sent To  
Notes
2020-09-17 14:11:23PLAN REVIEW / BUILDING
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER BUILDING - PX3169
 PLANS EXAMINER 1&2 FAMILY - SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 NEC 2014
  
 4TH REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 NOTE: 1 - A PRE-FAB GENERATOR PAD IS BEING PROPOSED:
  
 NOTE: 2 - ENGINEERING FOR THE PRE-FAB GENERATOR PAD HAS
 BEEN PREPARED BY A PROFESSIONAL ENGINEER. A VALID
 SIGNATURE AND SEAL IS REQUIRED. SEE COMMENTS UNDER
 SIGNATURE REVIEW.
  
 1. THE WEIGHT OF THE PROPOSED 22KW GENERATOR IS 445LBS.
 THE MINIMUM WEIGHT REQUIRED ON THE PAD ENGINEERING IS
 526LBS.
  
 2. THE TOTAL WEIGHT ON THE GENERATOR PAD ENGINEERING
 (UNIT + PAD) STATES 460LBS. THE WEIGHT OF THE PROPOSED
 GENERATOR (445LBS), PLUS THE WEIGHT OF THE PAD (240LBS)
 WOULD BE 685LBS.
 PLEASE CLARIFY.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2020-09-09 Cont ID  
Sent By cthroop Date 2020-09-09 Time 08:43 Rev Time 0.00
Received By cthroop Date 2020-09-09 Time 08:01 Sent To  
Notes
2020-09-09 08:48:56PLAN REVIEW / BUILDING
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER BUILDING - PX3169
 PLANS EXAMINER 1&2 FAMILY - SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 NEC 2014
  
 3RD REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED
 SATISFACTORILY ARE MARKED AS CORRECTED.
 PREVIOUS COMMENTS THAT HAVE NOT BEEN ADDRESSED
 SATISFACTORILY MAY HAVE ADDITIONAL COMMENTS IN
 PARENTHESES. ANY NEW COMMENT WILL BE LISTED AFTER
 PREVIOUS COMMENTS.
  
 2ND REVIEW
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 1. FBC R 301, IT APPEARS THAT A PREFAB SLAB IS
 PROPOSED. EITHER:
  
 PROVIDE ENGINEERING FOR THE PREFAB SLAB, OR
  
 PROVIDE A STRUCTURAL DETAIL WITH ALL INFORMATION
 INCLUDING CALCULATIONS TO SHOW HOW THE PROPOSED PREFAB
 SLAB WILL RESIST WIND LOADS, INCLUDING OVERTURNING AND
 SLIDING. THE DETAIL PROVIDED LACKS BASIC INFORMATION
 SUCH AS THICKNESS, DETAIL FOR THE SLAB CONSTRUCTION,
 REINFORCING STEEL, WIND DESIGN CRITERIA, ETC.
  
 (2ND REVIEW COMMENTS HAVE NOT BEEN NOT ADDRESSED)
  
 NEW COMMENT:
  
 1. PROVIDE SITE SPECIFIC WIND LOADS FOR THE GENERATOR.
  
 FBC 107.3.5.3 ? PROVIDE WIND DESIGN LOADS/DESIGN
 PRESSURES PURSUANT TO FBC-R301.2.
  
 R301.2.1 WIND DESIGN CRITERIA.
 BUILDINGS AND PORTIONS THEREOF SHALL BE CONSTRUCTED IN
 ACCORDANCE WITH THE WIND PROVISIONS OF THIS CODE USING
 THE BASIC WIND SPEED IN TABLE R301.2(1) AS DETERMINED
 FROM FIGURE R301.2(4).
  
  
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2020-08-21 Cont ID  
Sent By shill Date 2020-08-21 Time 16:19 Rev Time 0.00
Received By shill Date 2020-08-21 Time 16:17 Sent To  
Notes
2020-08-21 16:23:18****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 1. FBC R 301, IT APPEARS THAT A PREFAB SLAB IS
 PROPOSED. EITHER:
  
 PROVIDE ENGINEERING FOR THE PREFAB SLAB, OR
  
 PROVIDE A STRUCTURAL DETAIL WITH ALL INFORMATION
 INCLUDING CALCULATIONS TO SHOW HOW THE PROPOSED PREFAB
 SLAB WILL RESIST WIND LOADS, INCLUDING OVERTURNING AND
 SLIDING. THE DETAIL PROVIDED LACKS BASIC INFORMATION
 SUCH AS THICKNESS, DETAIL FOR THE SLAB CONSTRUCTION,
 REINFORCING STEEL, WIND DESIGN CRITERIA, ETC.
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-08-18 Cont ID  
Sent By cthroop Date 2020-08-18 Time 16:41 Rev Time 0.00
Received By cthroop Date 2020-08-18 Time 16:18 Sent To  
Notes
2020-08-18 16:44:49PLAN REVIEW GENERATOR - BUILDING
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER BUILDING - PX3169
 PLANS EXAMINER 1&2 FAMILY - SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 1ST REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. GENERATOR SPECIFICATIONS PROVIDED FOR REVIEW ARE
 DATED 2018. PROVIDE CURRENT 2020 GENERATOR SPECS.
 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS
 SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH
 107.2.5.
  
 2. PROVIDE GENERATOR PAD STRUCTURAL DETAIL.
 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS
 SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH
 107.2.5.
  
 3. DESIGNER SHALL SIGN GENERATOR PAD STRUCTURAL DETAIL.
 FBC 107.2.1 ALL INFORMATION, DRAWINGS, SPECIFICATIONS
 AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE
 OF THE PERSON RESPONSIBLE FOR THE DESIGN. (SEE ALSO
 SECTION 107.3.5), CHPT. 471, F.S. & 61G15 AND CHPT.
 481, F.S. & 61G1.
  
  
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2020-09-09 Cont ID  
Sent By cthroop Date 2020-09-09 Time 08:42 Rev Time 0.00
Received By cthroop Date 2020-09-09 Time 08:01 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2020-08-27 Cont ID  
Sent By cthroop Date 2020-08-27 Time 15:58 Rev Time 0.00
Received By cthroop Date 2020-08-27 Time 15:39 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2020-08-13 Cont ID  
Sent By jleahy Date 2020-08-13 Time 11:41 Rev Time 0.00
Received By jleahy Date 2020-08-13 Time 11:32 Sent To  
Notes
2020-08-13 11:50:55FLORIDA BUILDING CODE 2017 6TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED
 NFPA 70 2014 EDITION
  
 JAKE LEAHY BN, BU, PX
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
 1) NEED TO SHOW LOAD CALCULATION OF WHAT IS GOING ON
 GENERATOR.
  
 2) LOAD CALC AND RISER DIAGRAM TO BE SIGNED BY
 CONTRACTOR PRINT NAME, SIGN NAME, DATE.

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2020-10-05 Cont ID  
Sent By cthroop Date 2020-10-05 Time 07:48 Rev Time 0.00
Received By cthroop Date 2020-09-18 Time 10:08 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2020-09-17 Cont ID  
Sent By cthroop Date 2020-09-17 Time 14:22 Rev Time 0.00
Received By cthroop Date 2020-09-16 Time 12:01 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2020-09-15 Cont ID  
Sent By shill Date 2020-09-15 Time 14:55 Rev Time 0.00
Received By shill Date 2020-09-08 Time 10:38 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-09-04 Cont ID  
Sent By lmarchan Date 2020-09-04 Time 15:03 Rev Time 0.00
Received By lmarchan Date 2020-08-20 Time 14:24 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-08-18 Cont ID  
Sent By cthroop Date 2020-08-18 Time 16:44 Rev Time 0.00
Received By cthroop Date 2020-07-23 Time 09:40 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 5 Status P Date 2020-10-05 Cont ID  
Sent By cthroop Date 2020-10-05 Time 07:47 Rev Time 0.00
Received By cthroop Date 2020-10-03 Time 07:01 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 4 Status F Date 2020-09-17 Cont ID  
Sent By cthroop Date 2020-09-17 Time 14:11 Rev Time 0.00
Received By cthroop Date 2020-09-17 Time 13:14 Sent To  
Notes
2020-09-17 14:13:50PLAN REVIEW / SIGNATURES
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER BUILDING - PX3169
 PLANS EXAMINER 1&2 FAMILY - SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 4TH REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 RE: GENERATOR PAD ENGINEERING:
  
 DOCUMENTS PREPARED BY AN ARCHITECT OR ENGINEER AND
 SUBMITTED FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED,
 DATED ORIGINALS.
  
 EITHER UPLOAD A DIGITALLY SIGNED DOCUMENT OR DROP OFF
 (OR MAIL) ONE PAPER ORIGINAL WITH A WET SEAL AND
 SIGNATURE TO:
  
 BUILDING DIVISION, FIRST FLOOR
 CITY OF WEST PALM BEACH
 401 CLEMATIS ST
 WEST PALM BEACH, FL 33401
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status F Date 2020-09-09 Cont ID  
Sent By cthroop Date 2020-09-09 Time 08:50 Rev Time 0.00
Received By cthroop Date 2020-09-09 Time 08:01 Sent To  
Notes
2020-09-09 08:54:01PLAN REVIEW / BUILDING
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER BUILDING - PX3169
 PLANS EXAMINER 1&2 FAMILY - SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 NEC 2014
  
 3RD REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. ENGINEERING FOR PRE-FAB SLAB AND SITE SPECIFIC WIND
 LOADS HAVE NOT BEEN SUBMITTED FOR REVIEW. A REVIEW OF
 THE CONTRACTORS SIGNATURE OR DESIGN PROFESSIONALS
 DIGITAL SIGNATURE FOR THESE DOCUMENTS IS REQUIRED.
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2020-08-21 Cont ID  
Sent By shill Date 2020-08-21 Time 16:23 Rev Time 0.00
Received By shill Date 2020-08-21 Time 16:18 Sent To  
Notes
2020-08-21 16:24:34THIS REVIEW CANNOT BE PASSED UNTIL IT IS DETERMINED IF
 ENGINEERING WILL BE SUBMITTED. IF ENGINEERING IS
 SUBMITTED THE FOLLOWING IS APPLICABLE:
  
 ****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED FOR
 PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED
 ORIGINALS. A SCAN OF A WET SIGNATURE IS NOT CONSIDERED
 A DIGITAL SIGNATURE.
  
 EITHER UPLOAD A DIGITALLY SIGNED DOCUMENT OR DROP OFF
 (OR MAIL) ONE PAPER ORIGINAL:
  
 BUILDING DIVISION, FIRST FLOOR
 CITY OF WEST PALM BEACH
 401 CLEMATIS ST
 WEST PALM BEACH, FL 33401
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2020-08-13 Cont ID  
Sent By jleahy Date 2020-08-13 Time 11:54 Rev Time 0.00
Received By jleahy Date 2020-08-13 Time 11:51 Sent To  
Notes
2020-08-13 11:53:07FLORIDA BUILDING CODE 2017 6TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED
 NFPA 70 2014 EDITION
  
 JAKE LEAHY BN, BU, PX
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
 PLAN IS REQUIRED TO BE SIGNED AND SEALED BY A DESIGN
 PROFESSIONAL OR THE ELECTRICAL CONTRACTOR QUALIFIER. FS
 471.003(2)(H); 471.025; FBC 107.2.1
  
  

Review Stop Z ZONING
Rev No 3 Status P Date 2020-09-15 Cont ID  
Sent By rthermid Date 2020-09-15 Time   Rev Time 0.00
Received By rthermid Date 2020-09-15 Time   Sent To I
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2020-09-04 Cont ID  
Sent By rthermid Date 2020-09-04 Time   Rev Time 0.00
Received By rthermid Date 2020-09-04 Time   Sent To I
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2020-07-31 Cont ID  
Sent By rthermid Date 2020-07-31 Time   Rev Time  
Received By rthermid Date 2020-07-31 Time   Sent To I
Notes
2020-07-31 10:53:25ZONING PLAN REVIEW
 ________________________________________
  
 DATE OF REVIEW: 7/31/2020
 ________________________________________
  
 REVIEW STATUS: FAILED
 ________________________________________
  
 PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN
 REVIEW COMMENTS:
  
 1. THERE IS NO SETBACK INFORMATION ON THE PLANS.
 INDICATE SETBACK DIMENSIONS FROM THE PROPOSED GENERATOR
 EQUIPMENT TO ALL PROPERTY LINES. PURSUANT THE CITY OF
 WEST PALM BEACH ZONING AND LAND DEVELOPMENT REGULATIONS
 (ZLDR), SECTION 94-305(B)(4): MECHANICAL EQUIPMENT MAY
 NOT PROJECT MORE THAN 4 FEET INTO A REQUIRED SETBACK.
 ________________________________________
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 IF THE RESUBMITTAL IS NOT PREPARED BY A DESIGN
 PROFESSIONAL (ARCHITECT OR ENGINEER), AND THE PAGES ARE
 11X17 OR SMALLER, YOU MAY RESUBMIT, ALONG WITH A
 COMPLETED RESUBMITTAL FORM, VIA EMAIL TO
 [email protected]. THE EMAIL SHOULD INCLUDE THE PERMIT
 NUMBER AND "RESUBMITTAL" IN THE SUBJECT LINE. THE
 RESUBMITTAL FORM CAN BE FOUND AT THIS WEBSITE:
  
 HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B
 UILDING-PERMIT-FORMS
  
 IF THE FORM IS TEMPORARILY UNAVAILABLE, PLEASE REQUEST
 THAT IT BE SENT TO YOU BY EMAILING [email protected]
 ________________________________________
  
 QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING:
  
 RAFAELA THERMIDOR, ASSOCIATE PLANNER
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION
 401 CLEMATIS STREET - P.O. BOX 3147
 WEST PALM BEACH, FLORIDA 33402
  
 TTY: 800.955.8771
 E: [email protected]
 W: WPB.ORG


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved