Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2020-09-21 Cont ID  
Sent By jwitmer Date 2020-09-21 Time 15:14 Rev Time 0.00
Received By jwitmer Date 2020-09-21 Time 11:29 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-08-11 Cont ID  
Sent By jwitmer Date 2020-08-11 Time 08:58 Rev Time 0.00
Received By jwitmer Date 2020-08-11 Time 08:30 Sent To  
Notes
2020-08-11 08:53:19WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2017 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 20070746
 ADD: 2600 N MILITARY TRL.
 CONT: HOOVER CANVAS
 TEL: 561-768-3508
 E-MAIL: [email protected]
  
 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: TUES. AUGUST 11TH, 2020
 ACTION: DENIED
  
 1) NO SITE PLAN WAS PROVIDED SHOWING THE LOCATION OF
 THE NEW AWNING. 2017 FLORIDA BUILDING CODE W 2014 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1, ADMINISTRATION 107.2.1 INFORMATION ON
 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS SHALL BE
 OF SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE
 AND EXTENT OF THE WORK PROPOSED.
  
 2) THE SUBMITTED ENGINEERING PLAN SHOWS A 50 FOOT LONG
 STEEL TRUSS/ BAR JOIST SYSTEM TO BE WIELDED TO STEEL
 POST UPRIGHTS. THIS WELD WOULD NEED TO BE COMPLETED AT
 THE JOBSITE PLEASE PROVIDE DOCUMENTATION FOR THE
 FOLLOWING AT TIME OF INSPECTION:
 WELDED CONNECTIONS
 THE CONTRACTOR IS REQUIRED TO PROVIDE WELD PROCEDURE
 SPECIFICATIONS & WELDER OPERATOR PERFORMANCE
 QUALIFICATION RECORDS IN ACCORDANCE WITH THE REFERENCED
 STANDARDS AT TIME OF INSPECTION FOR FIELD WIELDING, ON
 THE JOB-SITE WIELDING. THIRD PARTY CERTIFICATION WILL
 BE REQUIRED. REPORTS SUBMITTED TO BUILDING INSPECTOR AT
 TIME OF FRAMING INSPECTION.
 2017 FBC-B 2204.1 WELDING
 1. WELD PROCEDURES SPECIFICATIONS
 2. QUALIFICATIONS OF WELDING PERSONAL
  
 3) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID
 19
 IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS
 561-718-9724.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-09-22 Cont ID  
Sent By lmarchan Date 2020-09-22 Time 17:11 Rev Time 0.00
Received By lmarchan Date 2020-09-11 Time 13:42 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-08-31 Cont ID  
Sent By lmarchan Date 2020-08-31 Time 16:46 Rev Time 0.00
Received By lmarchan Date 2020-07-29 Time 14:58 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2020-09-21 Cont ID  
Sent By jwitmer Date 2020-09-21 Time 15:15 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2020-07-29 Cont ID  
Sent By pvalenti Date 2020-07-29 Time 14:58 Rev Time 0.00
Received By pvalenti Date 2020-07-29 Time 14:58 Sent To  
Notes
2020-07-29 15:03:34PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
 FBC M = FBC MECHANICAL
  
 SIGNATURE REVIEW APPROVED BY PAPER ORIGINAL PLANS.

Review Stop Z ZONING
Rev No 2 Status P Date 2020-09-22 Cont ID  
Sent By eschneid Date 2020-09-22 Time 15:56 Rev Time 0.25
Received By eschneid Date 2020-09-22 Time 15:53 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2020-08-31 Cont ID  
Sent By eschneid Date 2020-08-31 Time 15:57 Rev Time 0.25
Received By eschneid Date 2020-08-31 Time 15:57 Sent To  
Notes
2020-08-31 16:16:33FAILED
  
 1) NO SURVEY/SITE PLAN WAS PROVIDED SHOWING THE
 LOCATION OF THE PROPOSED CANOPY.
  
 2) STAFF MAY HAVE COMMENTS ONCE THE SURVEY/SITE PLAN IS
 PROVIDED.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446
 [email protected]