Plan Review Details - Permit 20070736
Plan Review Stops For Permit 20070736
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 2 Status P Date 2020-08-31 Cont ID  
Sent By jwitmer Date 2020-08-31 Time 14:18 Rev Time 0.00
Received By jwitmer Date 2020-08-31 Time 14:02 Sent To  
Notes
***NONE***

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date   Cont ID  
Sent By   Date 2020-07-27 Time   Rev Time 0.00
Received By jwitmer Date 2020-07-27 Time 15:16 Sent To  
Notes
2020-07-27 15:44:33PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS
 REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
 19120504
 THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO
 [email protected]. THE INFORMATION SHOULD BE IN PDF
 FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE INCLUDE
 THE PERMIT NUMBER AND "SBESTOS" IN THE SUBJECT LINE.
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2020-08-31 Cont ID  
Sent By jwitmer Date 2020-08-31 Time 14:18 Rev Time 0.00
Received By jwitmer Date 2020-08-31 Time 14:03 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-07-27 Cont ID  
Sent By jwitmer Date 2020-07-27 Time 15:43 Rev Time 0.00
Received By jwitmer Date 2020-07-27 Time 15:16 Sent To  
Notes
2020-07-27 15:43:04WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2017 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 20070736
 ADD: 501 S. FLAGLER DR. 5TH FLOOR COMMON AREAS/ ADA
 RESTROOMS
 CONT: ANDERSON & MOORE CONSTRUCTION
 TEL: 561-348-4805
 E-MAIL: [email protected]
  
 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: MON. JULY 27TH/ 2020
 ACTION: DENIED
  
 1) CLARIFICATION IN PLANS. IN THE TITLE BLOCK THE PLANS
 STATE THEY ARE FOR FLOORS 4 & 5. THE INDEX STATES THE
 RESTROOMS ARE TO BE A SLTERNATE LAYOUT (ACCESSIBLE).
 PLEASE CLARIFY IN THE TITLE BLOCK OR IN THE BODY OF THE
 PLANS WHICH FLOOR IS TOHAVE THE ACCESSIBLE STALLS.
 107.2.1.2 ADDITIONAL INFORMATION IS REQUIRED,
 CLARIFICATION IN PLANS. THANK YOU.
  
  
 2) SHEET A1.1.4 DETAILS FOR ACCESSIBLE RESTROOMS SHOW
 THE GRAB BARS FOR THE WATER CLOSET MEASURED AT 36
 INCHES FROM FLOOR TO CENTER LINE OF THE GRAB BAR. 2017
 FBC-ACCESSIBILITY CODE SECTION 609.4 POSITION OF GRAB
 BARS. GRAB BARS SHALL BE INSTALLED IN A HORIZONTAL
 POSITION, 33 INCHES MINIMUM AND 36 INCHES MAXIMUM ABOVE
 THE FINISH FLOOR MEASURED TO THE TOP OF THE GRIPPING
 SURFACE, NOT CENTERLINE.
  
 3) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID
 19
 IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS
 561-718-9724.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2020-08-19 Cont ID  
Sent By jleahy Date 2020-08-19 Time 15:01 Rev Time 0.00
Received By jleahy Date 2020-08-19 Time 14:57 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2020-08-26 Cont ID  
Sent By pleduc Date 2020-08-26 Time   Rev Time 0.00
Received By pleduc Date 2020-08-26 Time 15:34 Sent To  
Notes
2020-08-26 15:34:32THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC,
 FIRE MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 PLEASE CONSIDER THE FOLLOWING AS PROVISO:
  
 THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED
 AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE
 PROVISO COMMENTS WILL RESULT IN A FAILED FIRE
 INSPECTION.
  
  
 1) THE EXISTING FIRE ALARM SYSTEM SHALL BE MAINTAINED
 AND REMAIN ACTIVE THROUGHOUT THE CONSTRUCTION PERIOD,
 INCLUDING DEMO.
  
  
  
 2) ANY AND ALL WORK ON THE FIRE ALARM SYSTEM OR
 DEVICES. INCLUDING DEMO, SHALL BE DONE UNDER SEPARATE
 PERMITS AND SHOP DRAWINGS.
  
  
  
 PETER LEDUC
 FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 561-804-4709
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2020-07-20 Cont ID  
Sent By pleduc Date 2020-07-20 Time   Rev Time 0.00
Received By pleduc Date 2020-07-20 Time 10:44 Sent To  
Notes
2020-07-20 10:46:42THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC,
 FIRE MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 PLEASE CONSIDER THE FOLLOWING AS PROVISO:
  
 THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED
 AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE
 PROVISO COMMENTS WILL RESULT IN A FAILED FIRE
 INSPECTION.
  
  
 1) THE EXISTING FIRE ALARM SYSTEM SHALL BE MAINTAINED
 AND REMAIN ACTIVE THROUGHOUT THE CONSTRUCTION PERIOD,
 INCLUDING DEMO.
  
  
  
 2) ANY AND ALL WORK ON THE FIRE ALARM SYSTEM OR
 DEVICES. INCLUDING DEMO, SHALL BE DONE UNDER SEPARATE
 PERMITS AND SHOP DRAWINGS.
  
  
  
 PETER LEDUC
 FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 561-804-4709
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-09-08 Cont ID  
Sent By lcrespo Date 2020-09-08 Time 17:43 Rev Time 0.00
Received By lcrespo Date 2020-08-25 Time 07:20 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-08-19 Cont ID  
Sent By jleahy Date 2020-08-19 Time 15:01 Rev Time 0.00
Received By jleahy Date 2020-07-17 Time 10:21 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2020-08-07 Cont ID  
Sent By medwards Date 2020-08-07 Time 15:13 Rev Time 0.00
Received By medwards Date 2020-08-07 Time 14:49 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2020-09-08 Cont ID  
Sent By lcrespo Date 2020-09-08 Time 17:42 Rev Time 0.00
Received By lcrespo Date 2020-09-08 Time 17:42 Sent To  
Notes
2020-09-08 17:43:1009/08/20 REVIEWED FOR CODE COMPLIANCE (PLUMBING)
  
 BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE
 COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN
 PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM
 THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND
 NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF
 PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY
 ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM
 REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES
 / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO
 AVOID VOIDING OF THE PERMIT.
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2020-08-17 Cont ID  
Sent By tklarge Date 2020-08-17 Time 14:13 Rev Time 0.00
Received By tklarge Date 2020-08-17 Time 06:02 Sent To  
Notes
2020-08-17 13:26:061) INDICATE ON THE PLANS WHICH FLOOR WILL BE RENOVATED
 TO COMPLY WITH THE FLORIDA BUILDING CODE-ACCESSIBILITY
 CODE.
 2) SHT. A1.1.1 - THE LENGTH OF THE STANDARD STALLS ARE
 SHOWN AS 52 1/2 INCHES DEEP. THE MINIMUM DEPTH OF THE
 STANDARD TOILET STALLS SHALL BE 60 INCHES FOR FLOOR
 MOUNTED WATER CLOSETS AND 56 INCHES FOR WALL HUNG WATER
 CLOSETS PER FBC-PLUMBING SEC.405.3.1.
 3) SHT. A1.1.1 - SHOW THE DEPTH OF THE HANDICAP
 ACESSIBLE TOILET STALLS. COMPLY WITH 2017 FBC - ACCESS.
 SEC.604.3.1.
 4) SHT. A1.1.4 - SHOW THE LOCATION OF THE DRINKING
 FOUNTAIN ON THE ALTERNATE RESTROOM PLAN. WPB AMEND. TO
 FBC SEC. 107.2.1.
 5) SHT. A2.1.1 - DETAILS #1, 7,8 &9 - THE GRAB BARS
 SHALL BE MEASURED TO THE TOP OF THE GRIPPING SURFACE
 PER 2017 FBC- ACCESS. SEC.609.4.
 6) SUBMIT A WATER AND SANITARY RISER DIAGRAM FOR THE
 PROPOSED CHANGES CHANGES TO SANITARY AND WATER SYSTEMS.
 WPB AMEND. TO FBC SEC. 107.3.5.1.3.
 7) SUBMIT THE TOTAL OCCUPANT LOAD FOR THIS FLOOR.
 REDUCTION IN THE EXISTING SANITARY FACILITIES MAY
 CREATE A PLUMBING CODE VIOLATION IN REGARDS TO THE
 MINIMUM NUMBER OF REQUIRED NUMBER PLUMBING FIXTURES PER
 FBC-PLUMBING TABLE 403.1. SHT. ALS 1.1 NOTES THE
 OCCUPANT LOAD AS 16 PERSONS. THIS DOES NOT SEEM
 CORRECT. PROVIDE THE SQUARE FOOTAGE OF THE FLOOR.
  
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 PLUMBING PLAN REVIEW
 561-805-6692
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2020-08-31 Cont ID  
Sent By jwitmer Date 2020-08-31 Time 14:18 Rev Time 0.00
Received By jwitmer Date 2020-08-31 Time 14:07 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2020-07-27 Cont ID  
Sent By jwitmer Date 2020-07-27 Time 15:43 Rev Time 0.00
Received By lcrespo Date 2020-09-08 Time 17:43 Sent To  
Notes
***NONE***