Plan Review Details - Permit 20070687
Plan Review Stops For Permit 20070687
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2020-08-21 Cont ID  
Sent By rmcphers Date 2020-08-21 Time 12:16 Rev Time 0.00
Received By rmcphers Date 2020-08-21 Time 12:16 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2020-07-31 Cont ID  
Sent By rmcphers Date 2020-07-31 Time 08:19 Rev Time 0.00
Received By rmcphers Date 2020-07-31 Time 08:19 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2020-07-31 Cont ID  
Sent By jleahy Date 2020-07-31 Time 16:00 Rev Time 0.00
Received By jleahy Date 2020-07-31 Time 15:59 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2020-08-05 Cont ID  
Sent By pleduc Date 2020-08-05 Time   Rev Time 0.00
Received By pleduc Date 2020-08-05 Time 09:40 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2020-07-20 Cont ID  
Sent By pleduc Date 2020-07-20 Time   Rev Time 0.00
Received By pleduc Date 2020-07-20 Time 09:48 Sent To  
Notes
2020-07-20 10:07:23THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
  
 1) SHEET ALS 1.1 - THERE IS AN INCORRECT INDICATION OR
 MISREPRESENTATION OF THE DIAGONAL DISTANCE.
  
 THE DIAGONAL DISTANCE MUST REPRESENT THE ENTIRE AREA
 SERVED.
  
 THE DIAGONAL DISTANCE MUST EXTEND TO THE OPPOSITE
 EXISTING OFFICE SPACE.
  
 THE EXIT SEPARATION INDICATION IS POINTING TO AN EXIT
 ACCESS POINT NOT THE ACTUAL EXIT.
  
 THE EXIT SEPARATION LINE MUST EXTEND TO THE EXISTING
 EXIT DOOR TO THE WAREHOUSE.
  
 PER NFPA 101, CH 7 MEANS OF EGRESS
  
 7.5.1.3.3 IN BUILDINGS PROTECTED THROUGHOUT BY AN
 APPROVED,
 SUPERVISED AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE
 WITH SECTION
 9.7, THE MINIMUM SEPARATION DISTANCE BETWEEN TWO EXITS,
 EXIT
 ACCESSES, OR EXIT DISCHARGES, MEASURED IN ACCORDANCE
 WITH 7.5.1.3.2,
 SHALL BE NOT LESS THAN ONE-THIRD THE LENGTH OF THE
 MAXIMUM OVERALL
 DIAGONAL DIMENSION OF THE BUILDING OR AREA TO BE
 SERVED.
  
 PLEASE REVIEW AND CORRECT.
  
  
  
 2) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET
 REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE
 ABOVE.
  
  
  
 3) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE.
  
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-08-21 Cont ID  
Sent By rmcphers Date 2020-08-21 Time 12:17 Rev Time 0.00
Received By rmcphers Date 2020-08-04 Time 13:58 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-07-31 Cont ID  
Sent By jleahy Date 2020-07-31 Time 16:00 Rev Time 0.00
Received By jleahy Date 2020-07-17 Time 14:43 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2020-07-24 Cont ID  
Sent By medwards Date 2020-07-24 Time 16:05 Rev Time 0.00
Received By medwards Date 2020-07-24 Time 16:05 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2020-07-29 Cont ID  
Sent By ccole Date 2020-07-29 Time 13:32 Rev Time 0.00
Received By ccole Date 2020-07-29 Time 13:13 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2020-08-21 Cont ID  
Sent By rmcphers Date 2020-08-21 Time 12:17 Rev Time 0.00
Received By rmcphers Date 2020-08-21 Time 12:17 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2020-07-31 Cont ID  
Sent By rmcphers Date 2020-07-31 Time 08:30 Rev Time 0.00
Received By rmcphers Date 2020-07-31 Time 08:30 Sent To  
Notes
***NONE***