Plan Review Details - Permit 20070393
Plan Review Stops For Permit 20070393 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2020-07-23 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-07-23 |
Time |
11:05 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-07-23 |
Time |
11:05 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2020-07-15 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-07-15 |
Time |
10:42 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-07-15 |
Time |
10:42 |
Sent To |
|
|
Notes |
2020-07-15 10:43:55 | ROOFING | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected]. | | CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1 | | AMENDMENTS | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | 1) PLEASE PROVIDE A DRAWING THAT SHOWS THE ROOFING | | LAYOUT, MEAN ROOF HEIGHT, ROOF SLOPE, SIZE OF ROOF ETC. | | 2) PRODUCT APPROVAL FOR THE FLAT DECK ROOFING = PLEASE | | CIRCLE THE ROOFING SYSTEM TO BE USED IN THE PRODUCT | | APPROVAL - IF NEEDED PLEASE PROVIDE SIGNED AND SEALED | | ADDITIONAL ATTACHMENT DETAILS FROM AN ARCHITECT OR | | ENGINEER FOR THE ROOF ZONES 2 AND 3 WHICH MAY REQUIRE A | | HIGHER WIND PRESSURE - SEE NOTES ON THE PRODUCT | | APPROVAL. | | 3) PLEASE PROVIDE THE FRONT PAGES FOR THE FLAT DECK | | FLORIDA (FL) ROOFING PRODUCT APPROVAL PROVIDED. | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2020-07-23 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-07-23 |
Time |
11:06 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-07-16 |
Time |
10:49 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2020-07-15 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-07-15 |
Time |
10:46 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-07-09 |
Time |
08:16 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
N |
Date |
2020-07-23 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-07-23 |
Time |
11:05 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-07-23 |
Time |
11:05 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2020-07-15 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-07-15 |
Time |
10:44 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-07-15 |
Time |
10:44 |
Sent To |
|
|
Notes |
2020-07-15 10:45:31 | IF SIGNED AND SEALED ADDITIONAL ATTACHMENT ENGINEERING | | IS REQUIRED = SIGNED AND SEALED DRAWINGS IN PROJECTDOX | | NEED TO BE DIGITALLY/ELECTRONICALLY SIGNED BY THE | | ENGINEER OR ARCHITECT TO BE USED IN ELECTRONIC PLAN | | REVIEW. DRAWINGS DO NOT SHOW IN "ADOBE READER" AS | | DIGITALLY/ELECTRONICALLY SIGNED. - OR - IF YOUR | | ENGINEER DOES NOT HAVE AN ELECTRONIC OR DIGITAL | | SIGNATURE - PLEASE DROP OFF (CITY HALL DROP BOX) THE | | ORIGINAL SIGNED AND SEALED DRAWINGS/DOCUMENTS ALONG | | WITH A "PLAN REVIEW REQUEST FORM" EXPLAINING THE REASON | | FOR SUBMITTING THE DOCUMENT OR DRAWINGS. PLAN REVIEW | | REQUEST FORM CAN BE OBTAINED BY E MAILING [email protected] | | AND ASKING FOR THE FORM. (AT THIS TIME DROP BOX ITEMS | | MAY TAKE 2 TO 3 WEEKS TO PROCESS - DUE TO LIMITED STAFF | | INSIDE THE BUILDING DEPT.) |
|
|
|