2020-07-07 13:55:29 | WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION |
| SERVICES/ BUILDING DIVISION |
| 2017 FBC- BUILDING PLAN REVIEW |
| W. P. B. PERMIT: 20070147 |
| ADD: 600 S. DIXIE HWY. # 452 |
| CONT: DESIGN FLOORS & HOMES LLC |
| TEL: 561-328-6255 |
| E-MAIL: [email protected] |
| |
| 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH |
| AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| ADMINISTRATION |
| |
| 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW |
| CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES |
| SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA |
| BUILDING CODE, BUILDING. |
| |
| 1ST REVIEW |
| DATE: TUES. JULY 07/2020 |
| ACTION: DENIED |
| |
| 1) THE 1ST DOCUMENT SUBMITTED IS LUXURY RIGID |
| ENGINEERED FLOORING SALES BROCHURE WAS SUBMITTED. |
| THE 2ND DOCUMENT SUBMITTED ON A 6 INCH CONCRETE SLAB |
| WITH DENRC 2 FLOORING AND INSULATED CEILING. THIS TEST |
| (RAL-TL18-308) IS FOR SOUND TRANSMISSION LOSS TO THE |
| ASTM E 413-6 STANDARD. |
| THE 3RD DOCUMENT SUBMITTED ON A 6 INCH CONCRETE SLAB |
| WITH DENRC 2 FLOORING AND INSULATED CEILNG. THIS TEST |
| (RAL-IN18-09) TO THE ASTM E-492-09. |
| BOTH OF THE TEST STATE THAT THEY WERE COMPLETED WITH |
| DROPPED CEILINGS. WITHIN THE DOCUMENTS THE PHOTOGRAPHS |
| WERE OMITTED BY THE CUSTOMER REQUEST. |
| THERE WERE NO TEST SUBMITTED FOR THE FLOOR FINISH |
| CLASSIFICATION AS REQUIRED IN SECTION 804.2 |
| CLASSIFICATION AND 804.3 TESTING AND IDENTIFICATION OF |
| THE 2017 FBC-B. |
| FLOOR INSULATION (FBC-B 2017) |
| FOR TILE, STONE, MARBLE, VINYL AND WOOD FLOORING ALL |
| NEED TO HAVE HAD THE SOUND UNDERLAYMENT TESTED FLOOR |
| ASSEMBLIES TO THE FOLLOWING STANDARDS AND MEET THE |
| QUALIFICATIONS LISTED UNDER EACH OF THE STANDARDS FOR A |
| 6 INCH CONCRETE FLOOR ASSEMBLY/ NO DROPPED CEILING: |
| PLEASE PROVIDE ALL THREE TEST REPORTS SHOWING |
| COMPLIANCE WITH: |
| |
| TYPE I AND II BUILDINGS |
| 1A) FBC-B 2017 1207.3 STRUCTURE-BORNE SOUND. |
| FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR |
| BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA |
| WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION |
| CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD |
| TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492. |
| |
| 1B) FBC-B 2017 1207.2 AIR-BORNE SOUND. |
| WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES |
| SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM |
| PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION |
| CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) |
| FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM |
| E 90. |
| |
| 1C) LVT & LPT LUXURY VINYL TILE. FLOOR FINISH |
| CLASSIFICATION AS REQUIRED IN SECTION 804.2 |
| CLASSIFICATION AND 804.3 TESTING AND IDENTIFICATION OF |
| THE 2017 FBC-B. |
| |
| 2) 107.3.5 MINIMUM PLAN REVIEW CRITERIA |
| 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH |
| AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| ADMINISTRATIVE CODE SECTION: |
| 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS AND |
| OR STRUCTURES. |
| 107.3.5.1 COMMERCIAL BUILDINGS |
| 107.3.5.1.1. BUILDING |
| |
| MISSING CODE DATA: |
| FLOOR PLAN. |
| |
| 3) CERTIFICATION BY CONTRACTOR. PLANS DRAWN BY THE |
| CONTRACTOR. 107.3.4.3 CERTIFICATION BY CONTRACTOR. |
| PLEASE NOTE THE EXCEPTION TO ENGINEERED PLANS UNDER |
| 471.003(H) ELECTRICAL/ PLUMBING/ MECHANICAL, |
| 481.229(1)(C) (BUILDING) REQUIRES THE CONTRACTOR FOR |
| THAT TRADE THAT WILL BE LICENSED IN THAT TRADE, WILL |
| ALSO BE THE CONTRACTOR THAT DESIGNS THE SYSTEM UNDER |
| THAT TRADE. THE CONTRACTOR (QUALIFIER) THAT CREATED / |
| DRAWN THE SET OF PLANS WILL NEED TO IDENTIFY THEMSELVES |
| AS THE AUTHOR OF THE PLANS. PLEASE PRINT YOUR NAME, |
| SIGN YOUR NAME AND LICENSE NUMBER FOR THE TRADE YOU ARE |
| LICENSED IN AND PLANS DRAWN. FOR EACH TRADE THE |
| CONTRACTOR RESPONSIBLE FOR THE DESIGN UNDER THE TRADE |
| LICENSED IN MUST PRINT THEIR NAME, SIGN THEIR NAME AND |
| LICENSE NUMBER, NOTE THESE PLANS APPEAR TO BE DRAWN BY |
| ONE INDUVIAL, THEY WOULD HAVE TO BE LICENSED AS A |
| BUILDING, ELECTRICAL AND PLUMBING CONTRACTOR TO SUBMIT |
| ALL THESE TRADES UNDER ONE SHEET. |
| |
| 4) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW |
| COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION |
| MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE |
| THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR |
| PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| |
| A THOROUGH REVIEW OF THE PLANS COULD NOT HAPPEN SINCE |
| THERE WAS A GREAT DEFICIENCY IN PLANS AND REQUIRED |
| DOCUMENTATION. WITH THE NEXT PLAN REVIEW CYCLE THERE |
| MAYBE ADDITIONAL REVIEW COMMENTS BECAUSE OF NEW PLANS |
| AND INFORMATION LACKING UNDER THE PRIOR REVIEW. |
| |
| PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID |
| 19 |
| IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS |
| 561-718-9724. |
| |
| JAMES A. WITMER BN, PX, SFP, CBO |
| SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT |
| 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 |
| TEL: 561-805-6717 |
| FAX: 561-805-6676 |
| E-MAIL: [email protected] |
| |
| |
| |