Plan Review Stops For Permit 20061315 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2020-10-29 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2020-10-29 |
Time |
08:58 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2020-10-29 |
Time |
08:48 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2020-10-01 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-10-01 |
Time |
12:15 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-10-01 |
Time |
12:15 |
Sent To |
|
|
Notes |
2020-10-01 12:17:25 | SHED | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected]. | | CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1 | | AMENDMENTS | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | 1) TIEDOWN DRAWING ARE NOT PART OF THE STATE APPROVED | | SHED DRAWINGS. PLEASE PROVIDE A SIGNED AND SEALED SHED | | TIEDOWN DRAWING SHOWING TIEDOWN DETAILS AND THE WIND | | DESIGN CRITERIA USED FROM AN ARCHITECT OR ENGINEER TO | | COMPLY WITH THE WIND LOADS PER FBC R301.2.1 | | | | | | FYI = SIGNED AND SEALED DRAWINGS NEED TO BE | | DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR | | ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW - OR - | | IF YOUR ENGINEER DOES NOT HAVE A ELECTRONIC OR DIGITAL | | SIGNATURE - PLEASE DROP OFF (CITY HALL DROP BOX) THE | | ORIGINAL SIGNED AND SEALED DOCUMENT ALONG WITH A "PLAN | | REVIEW REQUEST FORM" EXPLAINING THE REASON FOR | | SUBMITTING THE DOCUMENT OR DRAWINGS. PLAN REVIEW | | REQUEST FORM CAN BE OBTAINED BY E MAILING [email protected] | | AND ASKING FOR THE FORM. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2020-09-21 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-09-21 |
Time |
15:48 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2020-09-21 |
Time |
15:48 |
Sent To |
|
|
Notes |
2020-09-21 15:36:52 | SHED | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected]. | | CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1 | | AMENDMENTS | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | 1) PLEASE PROVIDE FLORIDA STATE APPROVED SHED DRAWINGS | | OR PRODUCT APPROVAL FOR THE PREFAB SHED. FBC WPB | | AMENDMENTS 107.3 EXCEPTION (1) | | 2) PLEASE PROVIDE A SIGNED AND SEALED SHED TIEDOWN | | DRAWING SHOWING TIEDOWN DETAILS AND THE WIND DESIGN | | CRITERIA USED FROM AN ARCHITECT OR ENGINEER TO COMPLY | | WITH THE WIND LOADS PER FBC R301.2.1 | | 3) PLEASE SHOW THE LOCATION OF THE SHED ON A SITE PLAN | | OR SURVEY SHOWING THE DISTANCES FROM THE PROPERTY LINES | | AND THE HOUSE. | | | | FYI = SIGNED AND SEALED DRAWINGS NEED TO BE | | DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR | | ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW - OR - | | IF YOUR ENGINEER DOES NOT HAVE A ELECTRONIC OR DIGITAL | | SIGNATURE - PLEASE DROP OFF (CITY HALL DROP BOX) THE | | ORIGINAL SIGNED AND SEALED DOCUMENT ALONG WITH A "PLAN | | REVIEW REQUEST FORM" EXPLAINING THE REASON FOR | | SUBMITTING THE DOCUMENT OR DRAWINGS. PLAN REVIEW | | REQUEST FORM CAN BE OBTAINED BY E MAILING [email protected] | | AND ASKING FOR THE FORM. | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2020-10-29 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2020-10-29 |
Time |
08:58 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2020-10-22 |
Time |
14:45 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2020-10-22 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2020-10-22 |
Time |
10:33 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2020-09-24 |
Time |
15:24 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2020-09-21 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-09-21 |
Time |
15:37 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-08-27 |
Time |
14:53 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
P |
Date |
2020-10-29 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2020-10-29 |
Time |
08:58 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2020-10-29 |
Time |
08:49 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
F |
Date |
2020-10-01 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-10-01 |
Time |
12:17 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-10-01 |
Time |
12:17 |
Sent To |
|
|
Notes |
2020-10-01 12:18:15 | SEE BUILDING PLAN REVIEW |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2020-09-21 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-09-21 |
Time |
15:36 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-09-21 |
Time |
15:36 |
Sent To |
|
|
Notes |
2020-09-21 15:37:46 | SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE | | DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR | | ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW. - OR - | | IF YOUR ENGINEER DOES NOT HAVE AN ELECTRONIC OR DIGITAL | | SIGNATURE - PLEASE DROP OFF (CITY HALL DROP BOX) THE | | ORIGINAL SIGNED AND SEALED DRAWINGS/DOCUMENTS ALONG | | WITH A "PLAN REVIEW REQUEST FORM" EXPLAINING THE REASON | | FOR SUBMITTING THE DOCUMENT OR DRAWINGS. PLAN REVIEW | | REQUEST FORM CAN BE OBTAINED BY E MAILING [email protected] | | AND ASKING FOR THE FORM. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2020-10-21 |
|
|
Cont ID |
|
Sent By |
rthermid |
Date |
2020-10-21 |
Time |
|
Rev Time |
0.00 |
Received By |
rthermid |
Date |
2020-10-21 |
Time |
|
Sent To |
I |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2020-09-09 |
|
|
Cont ID |
|
Sent By |
rthermid |
Date |
2020-09-09 |
Time |
|
Rev Time |
|
Received By |
rthermid |
Date |
2020-09-09 |
Time |
|
Sent To |
I |
|
Notes |
2020-09-09 09:13:42 | ZONING PLAN REVIEW | | ________________________________________ | | | | DATE OF REVIEW: 9/9/2020 | | ________________________________________ | | | | REVIEW STATUS: FAILED | | ________________________________________ | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | REVIEW COMMENTS: | | | | 1. PLEASE PROVIDE A MARKED SURVEY OF THE PROPERTY | | INDICATING THE LOCATION AND SETBACKS TO ALL PROPERTY | | LINES OF THE PROPOSED WORK | | ________________________________________ | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | IF YOU SUBMITTED A PAPER APPLICATION, AND YOU WOULD | | LIKE TO RESUBMIT ELECTRONICALY, EMAIL | | [email protected] AND REQUEST TO HAVE YOUR | | PROJECT CONVERTED TO PROJECTDOX. YOU WILL RECEIVE LOGIN | | INFORMATION AND A LINK TO UPLOAD YOUR RESUBMITTAL. | | PLEASE BE SURE TO ?COMPLETE THE UPLOAD TASK? WHEN YOU | | ARE FINISHED UPLOADING. | | | | ________________________________________ | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | RAFAELA THERMIDOR, ASSOCIATE PLANNER | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | 401 CLEMATIS STREET - P.O. BOX 3147 | | WEST PALM BEACH, FLORIDA 33402 | | | | TTY: 800.955.8771 | | E: [email protected] | | W: WPB.ORG | | |
|
|