Plan Review Stops For Permit 20061249 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2020-08-06 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-08-03 |
Time |
14:52 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-08-03 |
Time |
14:52 |
Sent To |
|
|
Notes |
2020-08-03 14:53:00 | NO NOTES |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2020-07-13 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-07-13 |
Time |
16:24 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-07-13 |
Time |
15:35 |
Sent To |
|
|
Notes |
2020-07-13 16:24:52 | PLAN REVIEW ? BUILDING - GENERATOR | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER BUILDING - PX3169 | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | CODES IN EFFECT: | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | 1ST REVIEW | | | | RESULTS: DENIED | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | BELOW. | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1) PROVIDE A SITE PLAN. SHOW LOCATION OF PROPOSED | | GENERATOR. | | 2) PROVIDE STRUCTURAL DETAIL OF GENERATOR PAD. | | 3) PROVIDE WIND DESIGN LOADS FOR THE GENERATOR PER FBC | | 107.3.5.3 AND R301.2 AS REQUIRED FOR THE GENERATOR PAD | | ENGINEERING. | | 4) STRUCTURAL DETAIL SHALL BE SIGNED AND SEALED BY A | | DESIGN PROFESSIONAL. | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2020-08-03 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-08-03 |
Time |
14:42 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-08-03 |
Time |
14:38 |
Sent To |
|
|
Notes |
2020-08-03 14:43:06 | PROVISO: PROVIDE ATS SPEC'S TO CITY INSPECTOR. CT |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2020-07-13 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-07-13 |
Time |
16:25 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-07-13 |
Time |
15:35 |
Sent To |
|
|
Notes |
2020-07-13 16:25:46 | PLAN REVIEW ? ELECTRICAL - GENERATOR | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER BUILDING - PX3169 | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | CODES IN EFFECT: | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | 1ST REVIEW | | | | RESULTS: DENIED | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | BELOW. | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1) PROVIDE SPECIFICATIONS FOR AUTOMATIC TRANSFER | | SWITCH. ? ATS | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | 107.2.5. | | | | 2) PROVIDE ELCTRICAL RISER DIAGRAHM. | | 3) PROVIDE RISER DIAGRAM OF EXISTING SERVICE. INCLUDE | | ADDITION OF GENERATOR AND ATS. NEC 215.5; WPB FBC | | 107.2.1 | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
N |
Date |
2020-07-28 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2020-07-28 |
Time |
19:52 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2020-07-28 |
Time |
19:50 |
Sent To |
|
|
Notes |
2020-07-28 19:52:50 | GAS REVIEW UNDER PERMIT 20070888 |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
F |
Date |
2020-07-13 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-07-13 |
Time |
16:25 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-07-13 |
Time |
15:35 |
Sent To |
|
|
Notes |
2020-07-13 16:26:29 | PLAN REVIEW ? FUEL GAS - GENERATOR | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER BUILDING - PX3169 | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | CODES IN EFFECT: | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | 1ST REVIEW | | | | RESULTS: DENIED | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | BELOW. | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1) GAS ISOMETRIC DRAWING: | | A) THE DRAWING IS INCOMPLETE AND MUST BE MODIFIED TO | | SHOW THE ENTIRE SYSTEM INCLUDING ALL BRANCH PIPES FROM | | THE METER TO THE MOST REMOTE OUTLET. THE BTUH LOAD OF | | EACH APPLIANCE AND THE LOCATIONS OF REGULATORS SHALL BE | | INDICATED ON THE DRAWING- SECTIONS G2412.3 & G2412.4 | | FBC RES. | | B) PROVIDE THE TOTAL DEVELOPED LENGTH OF THE SYSTEM | | FROM THE METER TO THE MOST REMOTE OUTLET, AND BRANCH | | LENGTH SIZES- SECTIONS G2413.4.1, G2413.4.2 & | | G2413.4.3. | | B) PROVIDE DELIVERY PRESSURE TO THE GENERATOR FROM THE | | OUTLET OF THE REGULATOR- SECTION G2421.1 | | C) CORRECT THE BTUH LOAD OF THE GENERATOR. THE | | SUBMITTED SPECS INDICATE 306.000 BTUH FULL LOAD- | | G2413.2 FBC RES. | | 2) SUBMIT SPECS FOR THE REGULATOR AT THE GENERATOR WITH | | MARKUPS TO INDICATE WHICH MODEL TO BE INSTALLED, INLET | | AND OUTLET PRESSURES, AND ORIFICE SIZE- SECTION | | G2421.1. | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2020-08-11 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2020-08-11 |
Time |
11:24 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2020-07-22 |
Time |
10:41 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2020-07-22 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2020-07-22 |
Time |
09:48 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2020-07-14 |
Time |
10:00 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2020-07-13 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-07-13 |
Time |
16:27 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-06-25 |
Time |
09:54 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
N |
Date |
2020-07-28 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2020-07-28 |
Time |
19:52 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2020-07-28 |
Time |
19:52 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
N |
Date |
2020-07-13 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-07-13 |
Time |
16:26 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-07-13 |
Time |
15:35 |
Sent To |
|
|
Notes |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
N |
Date |
2020-08-03 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-08-03 |
Time |
13:43 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-08-03 |
Time |
13:42 |
Sent To |
|
|
Notes |
2020-08-03 13:43:42 | REVIEW OPENED BY MISTAKE. CT |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2020-08-06 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-08-03 |
Time |
14:53 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-08-03 |
Time |
14:53 |
Sent To |
|
|
Notes |
2020-08-03 14:54:00 | NO NOTES |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2020-07-13 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-07-13 |
Time |
16:26 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-07-13 |
Time |
15:35 |
Sent To |
|
|
Notes |
2020-07-13 16:27:20 | PLAN REVIEW ? DIGITAL SIGNATURES AND SEALS - GENERATOR | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER BUILDING - PX3169 | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | CODES IN EFFECT: | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | 1ST REVIEW | | | | RESULTS: DENIED | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | BELOW. | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 5) THE ENGINEER'S DIGITAL SIGNATURE IS REQUIRED ON | | ELECTRONICALLY SUBMITTED DRAWINGS. FS 471 & FAC 61G15 | | | | 6) DIGITAL SIGNATURES/SEALS ARE NOT IN ACCORDANCE WITH | | FS 471, FS 481 AS NOTED. NEW SHEETS SUBMITTED IN THE | | NEXT REVIEW CYCLE REQUIRE REVIEW. | | | | 7) UPLOAD VIA THE PROJECTDOX PORTAL WITH DIGITAL | | SIGNATURES OF DESIGN PROFESSIONALS AS APPLICABLE; USE | | THE REQUIRED NAMING CONVENTION FOR EACH DOCUMENT. | | | | | | 8) FLORIDA PROFESSIONAL ENGINEERS MAY NOT SELF CERTIFY | | DIGITAL SIGATURES AND SEALS PER FS 668.003. | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2020-08-07 |
|
|
Cont ID |
|
Sent By |
kalexand |
Date |
2020-08-07 |
Time |
10:58 |
Rev Time |
0.00 |
Received By |
kalexand |
Date |
2020-08-07 |
Time |
10:56 |
Sent To |
I |
|
Notes |
2020-08-07 11:02:04 | REVIEW STATUS: PASSED WITH PROVISOS | | ________________________________________ | | | | THIS REVIEW HAS BEEN PASSED SUBJECT TO THE FOLLOWING | | PROVISOS: | | | | 1. PROVISO: AS STAMPED ON SURVEY, PURSUANT THE CITY OF | | WEST PALM BEACH ZONING AND LAND DEVELOPMENT REGULATIONS | | (ZLDR), SECTION 94-305(B)(4): MECHANICAL EQUIPMENT MAY | | NOT PROJECT MORE THAN 4 FEET INTO A REQUIRED SETBACK. | | ________________________________________ | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | ________________________________________ | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | KIZZI ALEXANDRE, ASSOCIATE PLANNER | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | 401 CLEMATIS STREET - P.O. BOX 3147 | | WEST PALM BEACH, FLORIDA 33402 | | | | P: 561.822.1442 | | TTY: 800.955.8771 | | E: [email protected] | | | | W: WPB.ORG | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
|
|
|
Cont ID |
|
Sent By |
kalexand |
Date |
2020-07-08 |
Time |
|
Rev Time |
|
Received By |
|
Date |
2020-07-08 |
Time |
|
Sent To |
I |
|
Notes |
2020-07-08 12:45:19 | ZONING PLAN REVIEW | | ________________________________________ | | | | DATE OF REVIEW: 7/8/20 | | ________________________________________ | | | | REVIEW STATUS: FAILED | | ________________________________________ | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | REVIEW COMMENTS: | | | | 1. PLEASE PROVIDE A SURVEY INDICATING THE LOCATION OF | | THE PROPOSED GENERATOR AND THE SETBACKS FROM THE | | PROPERTY LINE. | | ________________________________________ | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | IF THE RESUBMITTAL IS NOT PREPARED BY A DESIGN | | PROFESSIONAL (ARCHITECT OR ENGINEER), AND THE PAGES ARE | | 11X17 OR SMALLER, YOU MAY RESUBMIT, ALONG WITH A | | COMPLETED RESUBMITTAL FORM, VIA EMAIL TO | | [email protected]. THE EMAIL SHOULD INCLUDE THE PERMIT | | NUMBER AND "RESUBMITTAL" IN THE SUBJECT LINE. THE | | RESUBMITTAL FORM CAN BE FOUND AT THIS WEBSITE: | | | | HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B | | UILDING-PERMIT-FORMS | | | | IF THE FORM IS TEMPORARILY UNAVAILABLE, PLEASE REQUEST | | THAT IT BE SENT TO YOU BY EMAILING [email protected] | | ________________________________________ | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | KIZZI ALEXANDRE, ASSOCIATE PLANNER | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | 401 CLEMATIS STREET - P.O. BOX 3147 | | WEST PALM BEACH, FLORIDA 33402 | | | | P: 561.822.1442 | | TTY: 800.955.8771 | | E: [email protected] | | | | W: WPB.ORG | | |
|
|