Plan Review Details - Permit 20061195
Plan Review Stops For Permit 20061195
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2020-08-21 Cont ID  
Sent By shill Date 2020-08-21 Time 10:11 Rev Time 0.00
Received By shill Date 2020-08-21 Time 10:11 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-07-14 Cont ID  
Sent By cthroop Date 2020-07-14 Time 09:10 Rev Time 0.00
Received By cthroop Date 2020-07-14 Time 08:50 Sent To  
Notes
2020-07-14 09:11:46PLAN REVIEW ? BUILDING - GENERATOR
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER BUILDING - PX3169
 PLANS EXAMINER 1&2 FAMILY - SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 1ST REVIEW
  
 RESULTS: DENIED
  
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1) PROVIDE WIND DESIGN LOADS FOR THE GENERATOR PER FBC
 107.3.5.3 AND R301.2 AS REQUIRED FOR THE GENERATOR PAD
 ENGINEERING.
 2) STRUCTURAL DETAIL SHALL BE SIGNED AND SEALED BY A
 DESIGN PROFESSIONAL.
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2020-07-28 Cont ID  
Sent By cthroop Date 2020-07-14 Time 09:13 Rev Time 0.00
Received By cthroop Date 2020-07-14 Time 08:50 Sent To  
Notes
2020-07-14 09:19:58PROVISO: PROVIDE ATS SPEC'S TO CITY INSPECTOR. CT
  

Review Stop G GAS REVIEW
Rev No 1 Status P Date 2020-07-14 Cont ID  
Sent By cthroop Date 2020-07-14 Time 09:11 Rev Time 0.00
Received By cthroop Date 2020-07-14 Time 08:50 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-08-21 Cont ID  
Sent By shill Date 2020-08-21 Time 10:11 Rev Time 0.00
Received By shill Date 2020-08-11 Time 16:47 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-08-10 Cont ID  
Sent By cpuell Date 2020-08-10 Time 17:31 Rev Time 0.00
Received By cpuell Date 2020-06-25 Time 09:40 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status N Date 2020-07-14 Cont ID  
Sent By cthroop Date 2020-07-14 Time 09:13 Rev Time 0.00
Received By cthroop Date 2020-07-14 Time 08:50 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2020-08-19 Cont ID  
Sent By jgomez Date 2020-08-19 Time 15:49 Rev Time 0.00
Received By jgomez Date 2020-08-19 Time 15:49 Sent To  
Notes
2020-08-19 15:50:5708/19/2020
 ENGINEER DRAWING MATCHES ONE UPLOADED TO PROJECTDOX.
 CONCRETE PAD ENGINEERING DRAWING WITH EMBOSSED SEAL AND
 ORIGINAL SIGNATURE SENT TO STORAGE. JG.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2020-08-04 Cont ID  
Sent By jgomez Date 2020-08-04 Time 09:38 Rev Time 0.00
Received By jgomez Date 2020-08-04 Time 09:38 Sent To  
Notes
2020-08-04 09:40:241-ENGINEER WHO SIGNED AND SEALED THE CONCRETE PAD
 ENGINEERING IS NOT THE SAME ENGINEER WHO SIGNED/SEALED
 THE ORIGINAL ENGINEERING SUBMITTED. SEC. 107.3 CITY
 AMENDMENTS.
 THERE ARE THERE TWO OPTIONS TO ADDRESS THIS ISSUE:
 (1)SUBMIT ENGINEERING WITH ORIGINAL SEAL/SIGNATURE OF
 THE ENGINEER WHO SIGNED THE ORIGINAL SUBMITTAL. OR
 (2) UPLOAD TO PROJECTDOX NEW DOCUMENT SIGNED/SEALED BY
 THE NEW ENGINEER FOR BUILDING REVIEW.
 NOTE: IN ORDER TO EXPEDITE THE REVIEW PROCESS, IT IS
 PREFERABLE TO DOWNLOAD THE NEW ENGINEERING WITH A
 DIGITAL SIGNATURE. OTHERWISE, HARD COPY WITH ORIGINAL
 SEAL/SIGNATURE IS REQUIRED. WE CAN USE THE ONE
 SUBMITTED NOW IF IT MATCHES THE ONE THAT WAS DOWNLOADED
 TO PROJECTDOX.
  
 2- THE CONCRETE PAD ENGINEERING SUBMITTED DOESN'T MATCH
 THE ORIGINAL ENGINEERING THAT WAS UPLOADED TO
 PROJECTDOX. SEC. 107.3 CITY AMENDMENTS.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2020-07-14 Cont ID  
Sent By cthroop Date 2020-07-14 Time 09:11 Rev Time 0.00
Received By cthroop Date 2020-07-14 Time 08:50 Sent To  
Notes
2020-07-14 09:13:19PLAN REVIEW ? DIGITAL SIGNATURES AND SEALS - GENERATOR
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER BUILDING - PX3169
 PLANS EXAMINER 1&2 FAMILY - SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 1ST REVIEW
  
 RESULTS: DENIED
  
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1) THE ENGINEER'S DIGITAL SIGNATURE IS REQUIRED ON
 ELECTRONICALLY SUBMITTED DRAWINGS. FS 471 & FAC 61G15
  
 2) DIGITAL SIGNATURES/SEALS ARE NOT IN ACCORDANCE WITH
 FS 471, FS 481 AS NOTED. NEW SHEETS SUBMITTED IN THE
 NEXT REVIEW CYCLE REQUIRE REVIEW.
  
 3) UPLOAD VIA THE PROJECTDOX PORTAL WITH DIGITAL
 SIGNATURES OF DESIGN PROFESSIONALS AS APPLICABLE; USE
 THE REQUIRED NAMING CONVENTION FOR EACH DOCUMENT.
  
  
 4) FLORIDA PROFESSIONAL ENGINEERS MAY NOT SELF CERTIFY
 DIGITAL SIGATURES AND SEALS PER FS 668.003.
  
  

Review Stop Z ZONING
Rev No 1 Status P Date 2020-08-05 Cont ID  
Sent By rthermid Date 2020-08-05 Time   Rev Time  
Received By rthermid Date 2020-08-05 Time   Sent To I
Notes
***NONE***