Plan Review Stops For Permit 20061156 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2020-08-19 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-08-19 |
Time |
13:35 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-08-19 |
Time |
12:58 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2020-07-15 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-07-15 |
Time |
12:40 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-07-15 |
Time |
10:10 |
Sent To |
|
|
Notes |
2020-07-15 12:43:32 | PLAN REVIEW ? GENERATOR - BUILDING | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER BUILDING - PX3169 | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | CODES IN EFFECT: | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | 1ST REVIEW | | | | RESULTS: DENIED | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | BELOW. | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1) PROVIDE STRUCTURAL DETAIL OF GENERATOR PAD. | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | 107.2.5. | | | | 2) STRUCTURAL PAD DETAIL SHALL BE SIGNED BY DESIGNER. | | FBC 107.2.1 ALL INFORMATION, DRAWINGS, SPECIFICATIONS | | AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE | | OF THE PERSON RESPONSIBLE FOR THE DESIGN. (SEE ALSO | | SECTION 107.3.5), CHPT. 471, F.S. & 61G15 AND CHPT. | | 481, F.S. & 61G1. | | | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2020-08-19 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-08-19 |
Time |
13:22 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-08-19 |
Time |
12:58 |
Sent To |
|
|
Notes |
2020-08-19 13:23:05 | PROVISO: PROVIDE ATS SPECS. TO CITY INSPECTOR. CT |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2020-07-15 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-07-15 |
Time |
12:45 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-07-15 |
Time |
10:09 |
Sent To |
|
|
Notes |
2020-07-15 12:48:01 | PLAN REVIEW ? GENERATOR - ELECTRICAL | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER BUILDING - PX3169 | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | CODES IN EFFECT: | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | 1ST REVIEW | | | | RESULTS: DENIED | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | BELOW. | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1) PROVIDE SPECIFICATIONS FOR AUTOMATIC TRANSFER | | SWITCH. ATS | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | 107.2.5. | | | | 2) PROVIDE NEW LOAD CALCULATIONS. | | PROVIDE LOAD CALCULATION FOR SERVICE, INCLUDE EXISTING | | AND NEW LOADS TO CONFIRM CAPACITY OF SERVICE IS | | ADEQUATE. NEC 215.2, 220, 408.30; FBC RE E3602.2 | | | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
P |
Date |
2020-08-06 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2020-08-06 |
Time |
17:23 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2020-08-06 |
Time |
17:17 |
Sent To |
|
|
Notes |
2020-08-06 17:24:35 | 08/06/20 REVIEWED FOR CODE COMPLIANCE (GAS) | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM | | THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND | | NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF | | PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY | | ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | AVOID VOIDING OF THE PERMIT. | | | | LUIS A. CRESPO | | PLUMBING INSPECTOR / PLUMBING PLAN REVIEW | | AVAILABLE FROM 6:30 AM TO 7:30 AM / 2:00 PM TO 5:00 PM | | EMAIL: [email protected] CELL: 561-701-6437 | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
F |
Date |
2020-07-15 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-07-15 |
Time |
12:53 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-07-15 |
Time |
10:10 |
Sent To |
|
|
Notes |
2020-07-15 13:08:50 | PLAN REVIEW ? GENERATOR - ? FUEL GAS | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER BUILDING - PX3169 | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | CODES IN EFFECT: | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | 1ST REVIEW | | | | RESULTS: DENIED | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | BELOW. | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | SOW IS THE INSTALLATION OF A 48KW GENERATOR | | | | REVIEW OF CITY RECORDS INDICATES THERE IS AN EXISTING | | NG SERVICE AT THE RESIDENCE | | | | | | | | | | 1) GAS ISOMETRIC DRAWING: | | | | 1A) THE DRAWING IS INCOMPLETE AND MUST BE MODIFIED TO | | SHOW THE ENTIRE SYSTEM INCLUDING ALL BRANCH PIPES FROM | | THE METER TO THE MOST REMOTE OUTLET. THE BTUH LOAD OF | | EACH APPLIANCE AND THE LOCATIONS OF REGULATORS SHALL BE | | INDICATED ON THE DRAWING- SECTIONS G2412.3 & G2412.4 | | FBC RES. | | | | EXCEPTION PER TIM LARGE CHIEF PLUMBING INSPECTOR - IF | | IT IS NOT POSSIBLE TO GAIN ACCESS TO THE DWELLING UNIT | | YOU MAY ESTIMATE THE TOTAL BTUH OF THE EXISTING | | APPLIANCES. | | | | NOTE: THIS PLUMBING CONTRATOR INSTALLED THE GAS | | APPLIANCES FOR THE NEW RESIDENCE. I CAN PROVIDE A COPY | | OF THE EXISTING GAS RISER IF NEEDED. | | | | 1B) PROVIDE THE TOTAL DEVELOPED LENGTH OF THE SYSTEM | | FROM THE METER TO THE MOST REMOTE OUTLET, AND BRANCH | | LENGTH SIZES- SECTIONS G2413.4.1, G2413.4.2 & | | G2413.4.3. PROVIDED | | | | 1B) PROVIDE DELIVERY PRESSURE TO THE GENERATOR FROM THE | | OUTLET OF THE REGULATOR- SECTION G2421.1 | | | | 1C) PROVIDE THE BTUH LOAD OF THE GENERATOR. G2413.2 FBC | | RES. | | | | 1D) PROVIDE GENERATOR SPECS. G2413.2 FBC RES. | | | | 2) SUBMIT SPECS FOR THE REGULATOR AT THE GENERATOR WITH | | MARKUPS TO INDICATE WHICH MODEL TO BE INSTALLED, INLET | | AND OUTLET PRESSURES, AND ORIFICE SIZE- SECTION | | G2421.1. | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2020-08-19 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-08-19 |
Time |
13:35 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-08-05 |
Time |
07:17 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2020-07-15 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-07-15 |
Time |
13:10 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-06-25 |
Time |
09:35 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
N |
Date |
2020-08-06 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2020-08-06 |
Time |
17:17 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2020-08-06 |
Time |
17:17 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
N |
Date |
2020-07-15 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-07-15 |
Time |
12:44 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-07-15 |
Time |
10:10 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2020-08-05 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2020-08-05 |
Time |
07:14 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2020-08-05 |
Time |
07:14 |
Sent To |
|
|
Notes |
2020-08-05 07:15:08 | ORIGINAL ENGINEERING SUBMITTED | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2020-07-15 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-07-15 |
Time |
12:50 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-07-15 |
Time |
10:10 |
Sent To |
|
|
Notes |
2020-07-15 12:51:59 | PLAN REVIEW ? GENERATOR - DIGITAL SIGNATURES AND SEALS | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER BUILDING - PX3169 | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | CODES IN EFFECT: | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | 1ST REVIEW | | | | RESULTS: DENIED | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | BELOW. | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1) THE ENGINEER'S DIGITAL SIGNATURE IS REQUIRED ON | | ELECTRONICALLY SUBMITTED DRAWINGS. FS 471 & FAC 61G15 | | | | 2) DIGITAL SIGNATURES/SEALS ARE NOT IN ACCORDANCE WITH | | FS 471, FS 481 AS NOTED. NEW SHEETS SUBMITTED IN THE | | NEXT REVIEW CYCLE REQUIRE REVIEW. | | | | 3) UPLOAD VIA THE PROJECTDOX PORTAL WITH DIGITAL | | SIGNATURES OF DESIGN PROFESSIONALS AS APPLICABLE; USE | | THE REQUIRED NAMING CONVENTION FOR EACH DOCUMENT. | | | | | | 4) FLORIDA PROFESSIONAL ENGINEERS MAY NOT SELF CERTIFY | | DIGITAL SIGATURES AND SEALS PER FS 668.003. | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
|
|
|
Cont ID |
|
Sent By |
kalexand |
Date |
2020-07-08 |
Time |
|
Rev Time |
|
Received By |
|
Date |
2020-07-08 |
Time |
|
Sent To |
I |
|
Notes |
|
|