Plan Review Stops For Permit 20061041 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2020-10-02 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-10-02 |
Time |
13:18 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-10-02 |
Time |
13:14 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2020-07-27 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-07-27 |
Time |
10:36 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-07-27 |
Time |
09:22 |
Sent To |
|
|
Notes |
2020-07-27 10:37:23 | PLAN REVIEW ? GENERATOR - BUILDING | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER BUILDING - PX3169 | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | CODES IN EFFECT: | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | 1ST REVIEW | | | | RESULTS: DENIED | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | BELOW. | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1) PROVIDE WIND DESIGN LOADS FOR THE GENERATOR PER FBC | | 107.3.5.3 AND R301.2 AS REQUIRED FOR THE GENERATOR PAD | | ENGINEERING. | | 2) STRUCTURAL DETAIL OF PAD AND DESIGN LOADS SHALL BE | | SIGNED AND SEALED BY A DESIGN PROFESSIONAL. | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2020-07-27 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-07-27 |
Time |
10:36 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-07-27 |
Time |
09:22 |
Sent To |
|
|
Notes |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
P |
Date |
2020-10-01 |
|
|
Cont ID |
|
Sent By |
abelisle |
Date |
2020-10-01 |
Time |
04:53 |
Rev Time |
0.00 |
Received By |
abelisle |
Date |
2020-10-01 |
Time |
04:37 |
Sent To |
|
|
Notes |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
F |
Date |
2020-07-27 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-07-27 |
Time |
10:38 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-07-27 |
Time |
09:22 |
Sent To |
|
|
Notes |
2020-07-27 10:39:14 | PLAN REVIEW ? GENERATOR - FUEL GAS | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER BUILDING - PX3169 | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | CODES IN EFFECT: | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | 1ST REVIEW | | | | RESULTS: DENIED | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | BELOW. | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | CITY RECORDS INDICATE AN EXISTING GAS SERVICE AT THIS | | RESIDENCE. | | | | 1) GAS ISOMETRIC DRAWING: | | 1A) PROVIDE AN ISO DRAWING SHOWING THE ENTIRE SYSTEM | | INCLUDING ALL BRANCH PIPES FROM THE METER TO THE MOST | | REMOTE OUTLET. THE BTUH LOAD OF EACH EXISTING APPLIANCE | | AND THE LOCATIONS OF REGULATORS SHALL BE INDICATED ON | | THE DRAWING- SECTIONS G2412.3 & G2412.4 FBC RES. | | NOTE: YOU MAY PROVIDE THE EXISTING LOAD AS ONE | | CALCULATION ON THE GAS RISER | | 1B) PROVIDE THE TOTAL DEVELOPED LENGTH OF THE SYSTEM | | FROM THE METER TO THE MOST REMOTE OUTLET, AND BRANCH | | LENGTH SIZES- SECTIONS G2413.4.1, G2413.4.2 & | | G2413.4.3. PROVIDED | | 1B) PROVIDE DELIVERY PRESSURE TO THE GENERATOR FROM THE | | OUTLET OF THE REGULATOR- SECTION G2421.1 | | 1C) PROVIDE THE BTUH LOAD OF THE GENERATOR. G2413.2 FBC | | RES. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2020-10-02 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-10-02 |
Time |
13:18 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-09-17 |
Time |
07:35 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2020-07-27 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-07-27 |
Time |
10:36 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-07-07 |
Time |
15:05 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
N |
Date |
2020-10-01 |
|
|
Cont ID |
|
Sent By |
abelisle |
Date |
2020-10-01 |
Time |
04:36 |
Rev Time |
0.00 |
Received By |
abelisle |
Date |
2020-10-01 |
Time |
04:35 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
N |
Date |
2020-07-27 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-07-27 |
Time |
10:36 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-07-27 |
Time |
09:22 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2020-10-02 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-10-02 |
Time |
13:18 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-10-02 |
Time |
13:14 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2020-07-27 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-07-27 |
Time |
10:37 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-07-27 |
Time |
09:22 |
Sent To |
|
|
Notes |
2020-07-27 10:38:13 | PLAN REVIEW GENERATOR - DIGITAL SIGNATURES AND SEALS | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER BUILDING - PX3169 | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | CODES IN EFFECT: | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | 1ST REVIEW | | | | RESULTS: DENIED | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | BELOW. | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1) THE ENGINEER'S DIGITAL SIGNATURE IS REQUIRED ON | | ELECTRONICALLY SUBMITTED DRAWINGS. FS 471 & FAC 61G15 | | | | 2) DIGITAL SIGNATURES/SEALS ARE NOT IN ACCORDANCE WITH | | FS 471, FS 481 AS NOTED. NEW SHEETS SUBMITTED IN THE | | NEXT REVIEW CYCLE REQUIRE REVIEW. | | | | 3) UPLOAD VIA THE PROJECTDOX PORTAL WITH DIGITAL | | SIGNATURES OF DESIGN PROFESSIONALS AS APPLICABLE; USE | | THE REQUIRED NAMING CONVENTION FOR EACH DOCUMENT. | | | | | | 4) FLORIDA PROFESSIONAL ENGINEERS MAY NOT SELF CERTIFY | | DIGITAL SIGATURES AND SEALS PER FS 668.003. | | | | NOTE: YOU MAY PROVIDE A PAPER PLAN WITH WET SIGNATURE | | AND SEAL PRIOR TO PERMIT. | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
|
|
|
Cont ID |
|
Sent By |
kalexand |
Date |
2020-07-17 |
Time |
|
Rev Time |
|
Received By |
|
Date |
2020-07-17 |
Time |
|
Sent To |
I |
|
Notes |
|
|