Plan Review Stops For Permit 20061038 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2020-08-18 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-08-18 |
Time |
11:20 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-08-18 |
Time |
11:20 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2020-07-24 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-07-24 |
Time |
11:48 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-07-24 |
Time |
10:54 |
Sent To |
|
|
Notes |
2020-07-24 11:51:54 | PLAN REVIEW GENERATOR - BUILDING | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER BUILDING - PX3169 | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | CODES IN EFFECT: | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | 1ST REVIEW | | | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1) PROVIDE SITE SPECIFIC WIND LOAD DESIGN PRESSURE | | CALCULATIONS FOR THE GENERATOR PER FBC 107.3.5.3 AND | | R301.2 AND AS REQUIRED PER THE GENERATOR PAD | | ENGINEERING. CANNOT VERIFY IF GENERATOR PAD WIND LOADS | | ARE ADEQUATE. | | | | 2) SHOW LOCATION OF PROPOSED GENERATOR ON SURVEY. | | PROVIDE SETBACKS TO STRUCTURE, BUILDING OPENINGS AND | | PROPERTY LINES PER 107.2 CONSTRUCTION DOCUMENTS | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2020-07-24 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-07-24 |
Time |
11:47 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-07-24 |
Time |
10:54 |
Sent To |
|
|
Notes |
2020-07-24 11:48:21 | PROVISO: PROVIDE ATS SPEC'S TO CITY INSPECTOR. CT |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
P |
Date |
2020-07-24 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-07-24 |
Time |
11:47 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-07-24 |
Time |
10:54 |
Sent To |
|
|
Notes |
2020-07-24 11:47:46 | PROVISO: NEW SERVICE. PROVIDE LOW PRESSURE REG. SPEC'S | | TO CITY INSPECTOR. CT |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2020-08-22 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-08-22 |
Time |
10:23 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2020-08-17 |
Time |
07:20 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2020-08-06 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-08-06 |
Time |
15:07 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2020-07-07 |
Time |
15:04 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
N |
Date |
2020-07-24 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-07-24 |
Time |
11:48 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-07-24 |
Time |
10:54 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
P |
Date |
2020-08-22 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2020-08-22 |
Time |
10:22 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2020-08-22 |
Time |
10:22 |
Sent To |
|
|
Notes |
2020-08-22 10:23:39 | PETER E VALENTI | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6673 | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | FBC M = FBC MECHANICAL | | | | SIGNATURE REVIEW APPROVED BY SUBMITTAL OF ORIGINAL | | PAPER SIGNATURES. |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
F |
Date |
2020-08-22 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-08-22 |
Time |
10:13 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2020-08-18 |
Time |
11:20 |
Sent To |
|
|
Notes |
2020-08-18 11:20:18 | PLAN REVIEW GENERATOR - DIGITAL SIGNATURES AND SEALS | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER BUILDING - PX3169 | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | CODES IN EFFECT: | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | 2ND REVIEW | | | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1) THE DESIGNERS DIGITAL SIGNATURE ON THE GENERATOR PAD | | ENGINEERING CANNOT BE VERIFIED. FS 471 & FAC 61G15 | | | | 2) DIGITAL SIGNATURES ARE NOT IN ACCORDANCE WITH FS | | 471, FS 481 AS NOTED. NEW SHEETS SUBMITTED IN THE NEXT | | REVIEW CYCLE REQUIRE REVIEW. | | | | 3) UPLOAD VIA THE PROJECTDOX PORTAL WITH DIGITAL | | SIGNATURES OF DESIGN PROFESSIONALS AS APPLICABLE; USE | | THE REQUIRED NAMING CONVENTION FOR EACH DOCUMENT. | | | | | | OPTION: | | | | YOU MAY ELECT TO PROVIDE A HARD COPY OF PLANS WITH | | VALID SIGNATURE OF CONTRACTOR OR DESIGNER PRIOR TO | | PERMIT. A DROP BOX HAS BEEN INSTALLED OUTSIDE CITY HALL | | FOR THIS PURPOSE. CONTACT THE OFFICE OF DEVELOPMENT | | SERVICES @ 561-805-8700 OR [email protected] TO STATE YOUR | | INTENTIONS. CITY STAFF WILL REVIEW YOUR DOCUMENTS AND | | IF APPROVED YOU WILL RECIEVE AN E-MAIL INSTRUCTING YOU | | TO DOWNLOAD AND PRINT YOUR PERMIT AND PLANS. | | | | | | | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2020-07-24 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-07-24 |
Time |
11:52 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-07-24 |
Time |
10:54 |
Sent To |
|
|
Notes |
2020-07-24 11:52:55 | PLAN REVIEW GENERATOR - DIGITAL SIGNATURES AND SEALS | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER BUILDING - PX3169 | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | CODES IN EFFECT: | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | 1ST REVIEW | | | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1) THE DESIGNERS DIGITAL SIGNATURE ON THE GENERATOR PAD | | ENGINEERING CANNOT BE VERIFIED. FS 471 & FAC 61G15 | | | | 2) DIGITAL SIGNATURES ARE NOT IN ACCORDANCE WITH FS | | 471, FS 481 AS NOTED. NEW SHEETS SUBMITTED IN THE NEXT | | REVIEW CYCLE REQUIRE REVIEW. | | | | 3) UPLOAD VIA THE PROJECTDOX PORTAL WITH DIGITAL | | SIGNATURES OF DESIGN PROFESSIONALS AS APPLICABLE; USE | | THE REQUIRED NAMING CONVENTION FOR EACH DOCUMENT. | | | | | | OPTION: | | | | YOU MAY ELECT TO PROVIDE A HARD COPY OF PLANS WITH | | VALID SIGNATURE OF CONTRACTOR OR DESIGNER PRIOR TO | | PERMIT. A DROP BOX HAS BEEN INSTALLED OUTSIDE CITY HALL | | FOR THIS PURPOSE. CONTACT THE OFFICE OF DEVELOPMENT | | SERVICES @ 561-805-8700 OR [email protected] TO STATE YOUR | | INTENTIONS. CITY STAFF WILL REVIEW YOUR DOCUMENTS AND | | IF APPROVED YOU WILL RECIEVE AN E-MAIL INSTRUCTING YOU | | TO DOWNLOAD AND PRINT YOUR PERMIT AND PLANS. | | | | | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2020-08-10 |
|
|
Cont ID |
|
Sent By |
rthermid |
Date |
2020-08-10 |
Time |
|
Rev Time |
0.00 |
Received By |
rthermid |
Date |
2020-08-10 |
Time |
|
Sent To |
I |
|
Notes |
2020-08-10 08:28:14 | THE REQUIRED SETBACK IS 7.9 FT. THE GENERATOR MUST BE A | | MINIMUM OF 3.9 FEET FROM THE SIDE PROPERTY LINE. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2020-08-05 |
|
|
Cont ID |
|
Sent By |
rthermid |
Date |
2020-08-05 |
Time |
|
Rev Time |
|
Received By |
rthermid |
Date |
2020-08-05 |
Time |
|
Sent To |
I |
|
Notes |
2020-08-05 11:54:23 | ZONING PLAN REVIEW | | ________________________________________ | | | | DATE OF REVIEW: 8/5/2020 | | ________________________________________ | | | | REVIEW STATUS: FAILED | | ________________________________________ | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | REVIEW COMMENTS: | | | | 1. PROPOSED GENERATOR DOES NOT MEET SIDE SETBACK. | | PURSUANT THE CITY OF WEST PALM BEACH ZONING AND LAND | | DEVELOPMENT REGULATIONS (ZLDR), SECTION 94-305(B)(4): | | MECHANICAL EQUIPMENT MAY NOT PROJECT MORE THAN 4 FEET | | INTO A REQUIRED SETBACK. | | ________________________________________ | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | IF THE RESUBMITTAL IS NOT PREPARED BY A DESIGN | | PROFESSIONAL (ARCHITECT OR ENGINEER), AND THE PAGES ARE | | 11X17 OR SMALLER, YOU MAY RESUBMIT, ALONG WITH A | | COMPLETED RESUBMITTAL FORM, VIA EMAIL TO | | [email protected]. THE EMAIL SHOULD INCLUDE THE PERMIT | | NUMBER AND "RESUBMITTAL" IN THE SUBJECT LINE. THE | | RESUBMITTAL FORM CAN BE FOUND AT THIS WEBSITE: | | | | HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B | | UILDING-PERMIT-FORMS | | | | IF THE FORM IS TEMPORARILY UNAVAILABLE, PLEASE REQUEST | | THAT IT BE SENT TO YOU BY EMAILING [email protected] | | ________________________________________ | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | RAFAELA THERMIDOR, ASSOCIATE PLANNER | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | 401 CLEMATIS STREET - P.O. BOX 3147 | | WEST PALM BEACH, FLORIDA 33402 | | | | TTY: 800.955.8771 | | E: [email protected] | | W: WPB.ORG | | |
|
|