Plan Review Details - Permit 20060968
Plan Review Stops For Permit 20060968 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
N |
Date |
2020-07-17 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-07-17 |
Time |
09:48 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-07-17 |
Time |
09:48 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2020-07-08 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-07-08 |
Time |
13:27 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-07-08 |
Time |
13:16 |
Sent To |
|
|
Notes |
2020-07-08 13:27:46 | POOL BARRIER | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected]. | | | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | 1) A CONVENTIONAL SHADOW BOX FENCE DOES NOT COMPLY WITH | | THE FBC BARRIER REQUIREMENTS ( THE VERTICAL MEMBERS ON | | THE NEIGHBORS SIDE CANNOT HAVE A SPACE BETWEEN THEM OF | | MORE THAN 1 3/4" - YOU WOULD NEED TO ADD AN EXTRA | | VERTICAL MEMBER TO HAVE NO SPACE OR A SPACE LESS THAN 1 | | 3/4") PER FBC R4501.17.1.4 | | WHERE THE BARRIER IS COMPOSED OF HORIZONTAL AND | | VERTICAL MEMBERS AND THE DISTANCE BETWEEN THE TOPS OF | | THE HORIZONTAL MEMBERS IS LESS THAN 45 INCHES (1143 | | MM), THE HORIZONTAL MEMBERS SHALL BE LOCATED ON THE | | SWIMMING POOL SIDE OF THE FENCE. SPACING BETWEEN | | VERTICAL MEMBERS SHALL NOT EXCEED 1 3/4 INCHES (44 MM) | | IN WIDTH. WHERE THERE ARE DECORATIVE CUTOUTS WITHIN | | VERTICAL MEMBERS, SPACING WITHIN THE CUTOUTS SHALL NOT | | EXCEED 13/4 INCHES (44 MM) IN WIDTH. | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2020-07-20 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2020-07-20 |
Time |
09:12 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2020-06-18 |
Time |
14:27 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
N |
Date |
2020-07-08 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-07-08 |
Time |
13:28 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-07-08 |
Time |
13:28 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
|
|
|
Cont ID |
|
Sent By |
kalexand |
Date |
2020-07-17 |
Time |
|
Rev Time |
|
Received By |
|
Date |
2020-07-17 |
Time |
|
Sent To |
I |
|
Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |