Plan Review Details - Permit 20060955
Plan Review Stops For Permit 20060955
Review Stop G GAS REVIEW
Rev No 4 Status P Date 2020-09-28 Cont ID  
Sent By ccole Date 2020-09-28 Time 12:46 Rev Time 0.00
Received By ccole Date 2020-09-28 Time 12:46 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 3 Status F Date 2020-09-28 Cont ID  
Sent By ccole Date 2020-09-28 Time 08:46 Rev Time 0.00
Received By ccole Date 2020-09-28 Time 07:12 Sent To  
Notes
2020-09-28 08:46:593RD REVIEW FBC-2017 RES.
 PERMIT- 20060955
 9/25/2020
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH
 EDITION 2017
 FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 COMMENTS PROM THE PREVIOUS REVIEWS HAVE NOT BEEN
 ADDRESSED.
  
 1) REVISE THE RISER TO SHOW THE COMPLETE PIPING SYSTEM
 INCLUDING PIPE RUNS TO ALL NEW AND EXISTING APPLIANCES
 AND EQUIPMENT, AND SHOW THE CORRECT TOTAL AND
 INDIVIDUAL LOADS OF THE SYSTEM- SECTIONS G2412.3,
 G2412.4, & G2413.2 FBC RES. INCLUDE THE TOTAL LENGTH OF
 THE INTERIOR PIPING RUN AND THE TOTAL DEVELOPED LENGTH
 OF THE ENTIRE SYSTEM- SECTIONS G2413.4.1 AND G2413.4.2
 FBC RES. THE DRAWING SHALL INDICATE THE TYPE AND SIZE
 OF MAIN SUPPLY PIPE FROM THE METER TO THE TEE. PER CITY
 RECORDS AT A MINIMUM THERE IS AN EXISTING GAS WATER
 HEATER BUT ALL CONNECTED EXISTING HAPPLIANCES AVE TO BE
 ACCOUNTED FOR WHETHER LEGALLY PERMITTED OR NOT- SECTION
 107.2.1 WPB.
  
 A) THE SUBMITTED SPECS FOR THE KOHLER 20 KW INDICATE A
 FULL LOAD CAPACITY OF 340,000 BTUH AND AN INPUT
 PRESSURE AT 3.5-11 IN. W.C. PLEASE CORRECT THE LOAD ON
 THE DRAWING.
  
 B) AS PREVIOUSLY REQUESTED SHOW THE LOCATION OF THE
 REGULATOR AT THE GENERATOR, AND INDICATE THE MAKE AND
 MODEL. SHOW ALL UNIONS IN FRONT OF REGULATOR 1' OF
 EITHER SIDE; SHOW THE SHUTOFF VALVE, AND THE DRIP LEG-
 SECTIONS 2420.5, 2421.2, 2421.2(7), AND 2419.2 FBC RES.
 PLEASE SUBMIT MARKED UP OR HIGHLIGHTED SPECS FOR THE
 REGULATOR TO SHOW IT IS SUITABLE FOR OUTDOOR USE,
 INDICATE THE SELECTED MODEL, INLET AND OUTLET
 PRESSURES, AND ORIFICE SIZE.
  
 E) PIPE SIZING FOR THE SYSTEM SHALL BE IN ACCORDANCE
 WITH SECTION G2413.3 FBC RES. PLEASE SEE TABLES
 G2413.4(1)- G2413.4(8) AND LIST THE PIPE SIZING TABLE
 FOR EACH TYPE OF PIPING IN THE SYSTEM. TYPICALLY TABLE
 G2413.4(1) [402.4(2)] IS USED FOR LOW PRESSURE SCHED.
 40 METALLIC PIPE.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop G GAS REVIEW
Rev No 2 Status F Date 2020-07-28 Cont ID  
Sent By lcrespo Date 2020-07-28 Time 19:17 Rev Time 0.00
Received By lcrespo Date 2020-07-28 Time 19:17 Sent To  
Notes
2020-07-28 19:18:4007/28/20 2ND GAS/ REVIEW **DENIED** WITH COMMENTS
  
 NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS
 TIME AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE
 GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS.
  
 1. CITY RECORDS INDICATE AN EXISTING GAS METER. THE BTU
 LOAD OF THE EXISTING GAS SYSTEM MUST BE ADDED INTO THE
 TOTAL BTU LOAD ON THE SYSTEM TO ENSURE THE EXISTING
 SYSTEM IS PROPERLY SIZED. IF UNDERSIZED, THE EXISTING
 SYSTEM MUST BE REDONE TO ENSURE A SAFE OPERATING
 SYSTEM. SUBMIT A GAS PIPING RISER DIAGRAM THAT SHOWS
 THE TYPE OF EXISTING APPLIANCE, THE BTU LOAD OF EACH
 APPLIANCE, THE PIPE SIZE AND TYPE OF PIPE TO EACH
 APPLIANCE, AND THE DISTANCE OF THE LONGEST LENGTH OF
 PIPING FROM THE POINT OF DELIVERY TO THE MOST REMOTE
 OUTLET AND THE LOAD OF THE SECTION. NOTE: IF THE
 EXISTING SYSTEM IS LESS THAN A 2 PSI SYSTEM AND THE
 SYSTEM PRESSURE IS INCREASED TO 2 PSI, A LINE PRESSURE
 REGULATOR IS REQUIRED AT ALL THE EXISTING APPLIANCES
 PER THE 2017 FBC RES. SECS. G2412.4, G2412.8, G2413.1,
 G2413.2, G2413.3.
  
 2. SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE
 PRESSURE REGULATORS. REGULATORS INSTALLED ON THE
 EXTERIOR OF THE BUILDING SHALL BE APPROVED FOR OUTDOOR
 INSTALLATION PER THE 2017 FBC RES. SEC. G2421.1.
  
 3. PLEASE SHOW ALL UNIONS IN FRONT OF REGULATOR 1' OF
 EITHER SIDE PER THE 2017 FBC RES. SEC G2421.2.
  
 4. PLEASE LABEL THE SHUTOFF VALVE ON GAS ISOMERIC PER
 THE 2017 FBC RES. SEC. G2401.1.3.
  
 5. SHOW DRIP LEG ON EQUIPMENT INSTALLED PER THE 2017
 FBC RES. SEC. G2419.2 OR 2017 FBC FG 408.2.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION, MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 LUIS A. CRESPO
 PLUMBING INSPECTOR /
 PLUMBING PLAN REVIEW
 AVAILABLE FROM 6:30 AM 7:30 / 2:00 PM TO 5:00 PM
 [email protected]
 561-701-6437
  

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2020-07-02 Cont ID  
Sent By ccole Date 2020-07-02 Time 12:58 Rev Time 0.00
Received By ccole Date 2020-07-02 Time 12:02 Sent To  
Notes
2020-07-02 12:59:131ST REVIEW FBC-2017 RES.
 PERMIT- 20060995
 7/2/2020
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH
 EDITION 2017
 FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SIGNATURE OF THE FL. LICENSED GAS CONTRACTOR SHALL
 BE ON THE GAS PIPING LAYOUT DRAWING- SECTION 107.2.1
 WPB, AND FL. STATUTES 471 & 489.
  
 2) INDICATE THE PRESSURE AT THE METER AND SHOW THE
 LOCATION AND TYPE OF NEW SET DOWN REGULATOR TO BE
 INSTALLED IF REQUIRED- SECTION G2421 FBC RES.
  
 3) SUBMIT MANUFACTURER?S DATA SHEETS FOR THE GENERATOR,
 REGULATOR, AND QUICK CONNECT FLEX LINE- SECTION 107.2.1
 WPB.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2020-09-28 Cont ID  
Sent By ccole Date 2020-09-28 Time 08:48 Rev Time 0.00
Received By ccole Date 2020-09-26 Time 07:32 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-07-28 Cont ID  
Sent By lcrespo Date 2020-07-28 Time 19:20 Rev Time 0.00
Received By lcrespo Date 2020-07-21 Time 15:20 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2020-07-02 Time   Rev Time 0.00
Received By lmarchan Date 2020-06-18 Time 14:37 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status N Date 2020-09-28 Cont ID  
Sent By ccole Date 2020-09-28 Time 08:48 Rev Time 0.00
Received By ccole Date 2020-09-28 Time 07:12 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status N Date 2020-07-28 Cont ID  
Sent By lcrespo Date 2020-07-28 Time 19:18 Rev Time 0.00
Received By lcrespo Date 2020-07-28 Time 19:18 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status N Date 2020-07-02 Cont ID  
Sent By ccole Date 2020-07-02 Time 12:59 Rev Time 0.00
Received By ccole Date 2020-07-02 Time 12:02 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2020-09-28 Cont ID  
Sent By ccole Date 2020-09-28 Time 12:47 Rev Time 0.00
Received By ccole Date 2020-09-28 Time 12:47 Sent To  
Notes
2020-09-28 12:48:08CONTRACTOR DRAWN PLAN -SIGNED BY CONTRACTOR OF RECORD.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status N Date 2020-07-02 Cont ID  
Sent By ccole Date 2020-07-02 Time 13:00 Rev Time 0.00
Received By ccole Date 2020-07-02 Time 12:02 Sent To  
Notes
***NONE***