Plan Review Stops For Permit 20060943 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2020-07-21 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2020-07-21 |
Time |
09:52 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2020-07-21 |
Time |
08:05 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2020-06-29 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2020-06-29 |
Time |
15:20 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2020-06-29 |
Time |
14:01 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
P |
Date |
2020-07-30 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-07-30 |
Time |
11:59 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-07-30 |
Time |
10:59 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
F |
Date |
2020-07-21 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2020-07-21 |
Time |
16:26 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2020-07-21 |
Time |
16:26 |
Sent To |
|
|
Notes |
2020-07-21 16:31:42 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | FLORIDA BUILDING CODE 2017 6TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | NFPA 70 2014 EDITION | | | | JAKE LEAHY BN, BU, PX | | ELECTRICAL PLANS EXAMINER II | | 561-805-6713 | | [email protected] | | | | | | 1) VALUE OF WORK IS LOW PLEASE SUBMIT A SIGNED CONTRACT | | FOR WORK INVOLVED. | | | | 2) COMPLIED | | | | 3) COMPLIED | | | | 4) COMPLIED | | | | 5) COMPLIED | | | | 6) COMPLIED |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2020-07-01 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2020-07-01 |
Time |
12:47 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2020-07-01 |
Time |
12:47 |
Sent To |
|
|
Notes |
2020-07-01 13:00:24 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | FLORIDA BUILDING CODE 2017 6TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | NFPA 70 2014 EDITION | | | | JAKE LEAHY BN, BU, PX | | ELECTRICAL PLANS EXAMINER II | | 561-805-6713 | | [email protected] | | | | | | 1) VALUE OF WORK IS LOW PLEASE SUBMIT A SIGNED CONTRACT | | FOR WORK INVOLVED. | | | | 2) PANEL SHOWN IN LAUNDRY DOES NOT MEET 110.26 FOR | | WRKING CLEARANCES. | | | | 3) MASTER BDRM NEED TO MOVE SD TO CLOSE TO BATHROOM | | DOOR. | | | | 4) SUBFEEDER PIPE TO PANEL IS IT METAL IF NOT EQUIPMENT | | GROUND IS REQUIRED 250.122 | | | | 5) OUTLET IS REQUIRED AT THE FRONT AND REAR OF EACH | | DWELLING UNIT 210.52(E)(1) | | | | 6) COUNTER SPACE RECEPTACLES LOOKS LIKE IT DOES NOT | | MEET THE REQUIREMENTS 210.52(A)(4) |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2020-07-01 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2020-07-01 |
Time |
12:28 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2020-07-01 |
Time |
10:52 |
Sent To |
|
|
Notes |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
2 |
Status |
P |
Date |
2020-07-14 |
|
|
Cont ID |
|
Sent By |
aborngra |
Date |
2020-07-14 |
Time |
11:06 |
Rev Time |
0.00 |
Received By |
aborngra |
Date |
2020-07-14 |
Time |
11:06 |
Sent To |
|
|
Notes |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
P |
Date |
2020-06-29 |
|
|
Cont ID |
|
Sent By |
aborngra |
Date |
2020-06-29 |
Time |
14:45 |
Rev Time |
0.00 |
Received By |
aborngra |
Date |
2020-06-29 |
Time |
12:07 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2020-07-30 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-07-30 |
Time |
11:59 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-07-27 |
Time |
09:37 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2020-07-21 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2020-07-21 |
Time |
16:34 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2020-07-09 |
Time |
16:31 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2020-07-06 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2020-07-06 |
Time |
14:04 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2020-06-19 |
Time |
11:08 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2020-07-14 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2020-07-14 |
Time |
10:58 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2020-07-14 |
Time |
10:51 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2020-07-06 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2020-07-06 |
Time |
13:01 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2020-07-06 |
Time |
13:01 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2020-07-17 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2020-07-17 |
Time |
07:58 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2020-07-17 |
Time |
07:13 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2020-07-02 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2020-07-02 |
Time |
16:14 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2020-07-02 |
Time |
14:49 |
Sent To |
|
|
Notes |
2020-07-02 16:14:43 | 1ST REVIEW FBC-2017 RES. PLUMBING | | PERMIT- 20060943 | | 7/2/2020 | | | | CODES IN EFFECT: | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | EDITION 2017 | | FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017 | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | 2017 | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2017 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) SHEET P1: PLEASE CLARIFY THE SCOPE OF WORK FOR | | PLUMBING. THE DRAWING APPEARS TO SHOW AN ENTIRE NEW DWV | | SYSTEM TO BE INSTALLED, INCLUDING ALL NEW UNDERSLAB | | SANITARY DRAIN PIPING- SECTION 107.2.1 WPB. | | | | 2) P1- SANITARY RISER: A) PROVIDE THE SIZE OF THE | | WASHING MACHINE FIXTURE DRAIN, AND VENT- SECTION 406.2 | | FBC P. B) PROVIDE THE SIZE OF THE AAV AT THE DOUBLE | | BOWL KITCHEN SINK- SECTION P3114.6 FBC RES. | | | | 3) P1: PROVIDE AN EQUIPMENT SCHEDULE FOR THE NEW WATER | | HEATER INDICATING MAKE, MODEL, GALLON SIZE AND | | EFFICIENCY RATING- TABLE C404.2 FBC EC. PROVIDE A WATER | | HEATER PAN AND PAN DRAIN, AND SHOW THE TERMINATION | | LOCATION OF THE PAN DRAIN PIPE- SECTIONS P2801.6.1, | | P2801.6.2, AND P2801.6.2 FBC RES. | | | | 4) P1: PROVIDE THE DIMENSIONS OF THE NEW SHOWERS, AND | | THE WIDTH OF THE NEW SHOWER DOOR- SECTION P2708.1 FBC | | RES. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | CHRISTOPHER L. COLE | | MECHANICAL/PLUMBING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2020-07-21 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2020-07-21 |
Time |
09:55 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2020-07-21 |
Time |
09:55 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2020-06-29 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2020-06-29 |
Time |
15:20 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2020-06-29 |
Time |
14:01 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
N |
Date |
2020-06-29 |
|
|
Cont ID |
|
Sent By |
aborngra |
Date |
2020-06-29 |
Time |
14:45 |
Rev Time |
0.00 |
Received By |
aborngra |
Date |
2020-06-29 |
Time |
14:45 |
Sent To |
|
|
Notes |
|
|