Plan Review Details - Permit 20060784
Plan Review Stops For Permit 20060784
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2020-07-13 Cont ID  
Sent By jwitmer Date 2020-07-13 Time 17:44 Rev Time 0.00
Received By jwitmer Date 2020-07-13 Time 16:59 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-06-29 Cont ID  
Sent By jwitmer Date 2020-06-29 Time 13:26 Rev Time 0.00
Received By jwitmer Date 2020-06-29 Time 11:20 Sent To  
Notes
2020-06-29 11:21:462017 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 20060784
 ADD: 4801 DREHER TRL. N.
 CONT: GAST CONSTRUCTION
 TEL: 561-281-1001
 E-MAIL: ASHLEY.YOKOTA@GASTCONSTTRUCTION GROUP.COM
  
 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 1ST REVIEW
 DATE: MON. JUNE 29TH/ 2020
 ACTION: DENIED
  
 1) 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATIVE CODE SECTION:
 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS AND
 OR STRUCTURES.
 107.3.5.1 COMMERCIAL BUILDINGS
 107.3.5.1.1. BUILDING
 MISSING CODE DATA:
 SET BACK / SEPARATION (ASSUMED PROPERTY LINES)
 FLOOD HAZARD AREAS, FLOOD ZONES, AND DESIGN FLOOD
 ELEVATIONS
 PROPOSED FLOOD ELEVATION CERTIFICATE FOR STRUCTURES IN
 A SPECIFIC FLOOD HAZARD AREAS
 OCCUPANCY GROUP
 MINIMUM TYPE OF CONSTRUCTION
 FIRE RESISTANCE SEPARATION
 LIFE SAFETY PLANS SHALL DETERMINE AND SHALL INCLUDE THE
 FOLLOWING:
 OCCUPANT LOAD AND EGRESS CAPACITIES
 GROSS OR NET
 MEANS OF EGRESS EXIT ACCESS
 EXIT
 EXIT DISCHARGE
 STRUCTURAL REQUIREMENTS SHALL INCLUDE:
 DESIGN LOADS
 WIND REQUIREMENTS
 BUILDING ENVELOPE
 STRUCTURAL CALCULATIONS/ IF REQUIRED.
 FOUNDATION
 FLOOD REQUIREMENTS IN ACCORDANCE WITH SECTION 1612
 WALL SYSTEMS/OR COLUMNS
 ROOF SYSTEMS
  
 2) SHEET LP-1 :
  
 2A THE GRADING PLAN INDICATES THE FLOOR ELEVATION OF
 THE EXISTING BUILDING AT 12.08 FEET. THE PLAN DOES NOT
 INDICATE IF THIS ELEVATION IS IN NGVD OR NAVD88? THE
 NEW PAVILION FINISH FLOOR ELEVATION IS NOT GIVEN. )
 BOTH BUILDINGS ARE IN AN AE FLOOD ZONE.
 2B) ARTICLE XVII ORDINANCES ARTICLE XVII FLOOD
 PREVENTION & CONTROL.
 FBC BUILDING 1612 AND CITY OF WPB CODE OF SECTION
 94-546. STRUCTURE IS LOCATED IN AN "A" FLOOD ZONE. A
 FLOOD ELEVATION CERTIFICATE WILL BE REQUIRED. PLEASE
 REVIEW CITY ORDINANCE FOR THE CITY REQUIREMENTS REQUIRE
 AN ADDITIONAL 6 INCHES/ (12 INCHES OF ELEVATION IF
 PERMIT APPLICATION AFTER SEPT. 12/2016,
 AFTER OCT. 11/ 2017 AN ADDITIONAL ONE FOOT OF FREE
 BOARD WILL BE REQUIRED OR (2) FEET ABOVE BASE FLOOD.
 AFTER OCT. 11/ 2017 THE BUILDING DEPARTMENT WILL HAVE
 ADOPTED THE NEW FLOOD MAPS AND ALSO IN TOUGHS MAPS THE
 NAVD 88 ELEVATIONS. YOU CAN GO TO THE WEBSITE:
 WWW.NGS.NOAA.GOV/TOOLS/VERTCON/VERTCON.HTML FOR
 CONVERSIONS.
 2C) DURING THE PERMITTING OF THIS STRUCTURE THERE WILL
 BE REQUIRED (3) DIFFERENT FLOOD ZONE CERTIFICATES
 REQUIRED:
 (1) A FLOOD ZONE CERTIFICATE IS REQUIRED AS PART OF THE
 PLAN REVIEW DOCUMENTS WITH THE PROPOSED FINISH FLOOR
 HEIGHT. W. P. B. ADMINISTRATIVE CODE 107.3.5.1.1
 BUILDING MINIMUM PLAN REVIEW CRITERIA FOR COMMERCIAL
 BUILDINGS. ( 8) FLOOD REQUIREMENTS ELEVATIONS,
 ENCLOSURES, FLOOD DAMAGE-RESISTANT MATERIALS.
 (2) ONCE THE FIRST FLOOR SLAB IS POURED THE 2ND
 ELEVATION CERTIFICATE IS REQUIRED. W. P. B.
 ADMINISTRATIVE CODE 110.3 REQUIRED INSPECTIONS 1.2
 FLOOR/ SLAB INSPECTION. IN FLOOD HAZARD AREAS, UPON
 PLACEMENT OF THE LOWEST FLOOR, INCLUDING BASEMENT, AND
 PRIOR TO FURTHER VERTICAL CONSTRUCTION, THE ELEVATION
 CERTIFICATION, REQUIRED IN SECTION 1612.5, SHALL BE
 SUBMITTED TO THE BUILDING OFFICIAL.
  
 (3) BEFORE THE ISSUANCE OF A CERTIFICATE OF OCCUPANCY
 OR A CERTIFICATE OF COMPLETION THE 3RD FLOOD ZONE
 CERTIFICATE IS REQUIRED WITH THE HEIGHT OF ALL EXTERIOR
 ATTENDANTS A/C PADS OR OTHER SLABS FOR GENERATORS.
 W. P. B. ADMINISTRATIVE CODE 110.3 REQUIRED INSPECTIONS
 (6) FINAL INSPECTION. TO BE MADE AFTER THE BUILDING IS
 COMPLETED AND READY FOR OCCUPANCY. 6.1. LOWEST FLOOR
 ELEVATION. IN FLOOD HAZARD AREAS, AS PART OF THE FINAL
 INSPECTION, A FINAL CERTIFICATION OF THE LOWEST FLOOR
 ELEVATION SHALL BE SUBMITTED TO THE AUTHORITY HAVING
 JURISDICTION.
  
 FEMA NEW FORM AVAILABLE JUNE 13/2016.
 OMB NO. 1660-0008
 EXPIRATION DATE: NOV. 30/2018
 HTTP://WWW.FEMA.GOV/BUSINESS/NFIP/ELVINST.SHTM
  
 3) THE SUBMITTED SOILS REPORT FROM ALTERA IT WOULD SEAM
 TO BE A PAPER COPY THAT WAS UPLOADED. FLORIDA
 ADMINISTRATIVE CODE 61G15-23.005 (3)(C) A SCANNED,
 FACSIMILE, DIGITALLY CREATED OR COPIED IMAGE OF THE
 LICENSEE?S SIGNATURE SHALL NOT BE USED ON DIGITALLY
 SIGNED AND SEALED ENGINEERING PLANS, SPECIFICATIONS,
 REPORTS OR OTHER DOCUMENTS.
  
 4) THERE ARE NO STRUCTURAL SHEETS GIVING THE STRUCTURAL
 DESIGN AND FABRICATION REQUIRED FOR THE PROPOSED
 PAVILION. THE SUBMITTED FOREVER REDWOOD DRAWINGS 1-9 IT
 APPEARS TO BE DIGITALLY SIGNED AND SEALED. THERE IS NO
 DESIGNER OF RECORD FOR THE PAVILION. THE SUBMITTED 9
 SHEETS FROM FOREVER REDWOOD ARE MORE OF A SALES
 BROCHURE OF THE PAVILION, THERE SHOULD BE ENGINEERED
 DRAWINGS. SHEET 7 OF 9 STATES SEE STRUCTURAL DRAWINGS
 FOR CONNECTIONS.
  
 2017 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING
 CODE, CHAPTER 1, ADMINISTRATION 107.2.1.
 W.P.B. ADMINISTRATIVE CODE/2017 DRAWINGS &
 SPECIFICATIONS SHALL CONTAIN INFORMATION, IN THE FORM
 OF NOTES OR OTHERWISE, AS TO THE QUALITY OF MATERIALS,
 WHERE QUALITY IS ESSENTIAL TO CONFORMITY WITH THE
 TECHNICAL CODES. CONSTRUCTION DOCUMENTS SHALL BE
 SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND
 EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT IT
 WILL CONFORM TO THE PROVISIONS OF THIS CODE AND
 RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS
 DETERMINED BY THE BUILDING OFFICIAL.
  
 5) THERE ARE 2 DIFFERENT ROOFING PRODUCT APPROVALS,
 BOTH HAVE MULTIPLE SUB-SYSTEMS, DIFFEENT METAL ROOFING
 STYLES, AND PRESSURES WITH VARIOUS ANCHOR SPACINGS
 NOTHING HAS BEEN IDENTIFIED AS TO WHICH SUB-SYSTEM AND
 ANCHOR SPACING WAS IDENTIFIED.
  
 107.2.1.2 FOR ROOF ASSEMBLIES REQUIRED BY THE CODE, THE
 CONSTRUCTION DOCUMENTS SHALL ILLUSTRATE, DESCRIBE AND
 DELINEATE THE TYPE OF ROOFING SYSTEM, MATERIALS,
 VENTING, FASTENING REQUIREMENTS, FLASHING REQUIREMENTS
 AND WIND RESISTANCE RATING THAT ARE REQUIRED TO BE
 INSTALLED. PRODUCT EVALUATION AND INSTALLATION SHALL
 INDICATE COMPLIANCE WITH THE WIND CRITERIA REQUIRED FOR
 THE SPECIFIC SITE.
  
 6) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 A THOROUGH REVIEW OF THE PLANS COULD NOT HAPPEN SINCE
 THERE WAS A GREAT DEFICIENCY IN PLANS AND REQUIRED
 DOCUMENTATION. WITH THE NEXT PLAN REVIEW CYCLE THERE
 MAYBE ADDITIONAL REVIEW COMMENTS BECAUSE OF NEW PLANS
 AND INFORMATION LACKING UNDER THE PRIOR REVIEW.
  
 PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID
 19 IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS
 561-718-9724.
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  

Review Stop E ELECTRICAL
Rev No 1 Status N Date 2020-07-01 Cont ID  
Sent By jleahy Date 2020-07-01 Time 17:10 Rev Time 0.00
Received By jleahy Date 2020-07-01 Time 17:10 Sent To  
Notes
2020-07-01 17:11:14NO ELECTRIC SHOWN JLEAHY

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2020-07-10 Cont ID  
Sent By pleduc Date 2020-07-10 Time   Rev Time 0.00
Received By pleduc Date 2020-07-10 Time 12:26 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2020-06-30 Cont ID  
Sent By pleduc Date 2020-06-30 Time   Rev Time 0.00
Received By pleduc Date 2020-06-30 Time 10:28 Sent To  
Notes
2020-06-30 10:48:25THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
  
 1) THERE ARE INDICATIONS OF A CONCRETE SLAB AND RAMPS,
 HOWEVER, THERE IS NO DISCERNABLE GRADE INDICATION TO
 ENSURE A RAILING/GUARD IS REQUIRED.
  
 PER NFPA 101 CH 7
  
 7.2.5 RAMPS.
 7.2.5.1 GENERAL. EVERY RAMP USED AS A COMPONENT IN A
 MEANS OF
 EGRESS SHALL CONFORM TO THE GENERAL REQUIREMENTS OF
 SECTION 7.1
 AND TO THE SPECIAL REQUIREMENTS OF 7.2.5.
  
 7.2.5.5 GUARDS AND HANDRAILS.
 7.2.5.5.1 GUARDS COMPLYING WITH 7.2.2.4 SHALL BE
 PROVIDED FOR
 RAMPS, UNLESS OTHERWISE PROVIDED IN 7.2.5.5.4.
 7.2.5.5.2 HANDRAILS COMPLYING WITH 7.2.2.4 SHALL BE
 PROVIDED
 ALONG BOTH SIDES OF A RAMP RUN WITH A RISE GREATER THAN
 6 IN. (150
 MM), UNLESS OTHERWISE PROVIDED IN 7.2.5.5.4.
 7.2.5.5.3 THE HEIGHT OF HANDRAILS AND GUARDS SHALL BE
 MEASURED
 VERTICALLY TO THE TOP OF THE GUARD OR RAIL FROM THE
 WALKING SURFACE
 ADJACENT THERETO.
 7.2.5.5.4 THE REQUIREMENTS OF 7.2.5.5.1 AND 7.2.5.5.2
 SHALL NOT
 APPLY TO GUARDS AND HANDRAILS PROVIDED FOR RAMPED
 AISLES IN
 ASSEMBLY OCCUPANCIES AS OTHERWISE PROVIDED IN CHAPTERS
 12 AND
 13.
  
 7.2.5.7 SPECIAL PROVISIONS FOR OUTSIDE RAMPS.
 7.2.5.7.1* VISUAL PROTECTION. OUTSIDE RAMPS SHALL BE
 ARRANGED TO
 AVOID ANY IMPEDIMENTS TO THEIR USE BY PERSONS HAVING A
 FEAR OF
 HIGH PLACES. OUTSIDE RAMPS MORE THAN 36 FT (11 M) ABOVE
 THE
 FINISHED GROUND LEVEL SHALL BE PROVIDED WITH AN OPAQUE
 VISUAL
 OBSTRUCTION NOT LESS THAN 48 IN. (1220 MM) IN HEIGHT.
 7.2.5.7.2* WATER ACCUMULATION. OUTSIDE RAMPS AND
 LANDINGS
 SHALL BE DESIGNED TO MINIMIZE WATER ACCUMULATION ON
 THEIR
 SURFACES.
  
 PLEASE REVIEW AND PROVIDE DETAILS.
  
  
  
 2) ON SHEET 2 OF 9 OF THE FOREVER REWOOD SPEC SHEETS
 THERE ARE NO INDICATIONS OF CEILING FANS; HOWEVER,
 THERE ARE NO INDICATIONS OF ELECTRICAL WORK.
  
 ADDITIONALLY, THERE ARE NO INDICATIONS OF LIGHTING FOR
 THE PROPOSED.
  
 ANY ELECTICAL WORK WOULD REQUIRE PERMIITING AND PLAN
 SHEETS.
  
 PLEASE CORRECT OR PROVIDE A NOTE OF NO ELECTIC IS BEING
 PROPOSED.
  
  
  
 3) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET
 REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE
 ABOVE.
  
  
 4) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-07-15 Cont ID  
Sent By lmarchan Date 2020-07-15 Time 15:04 Rev Time 0.00
Received By lmarchan Date 2020-07-09 Time 14:51 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-07-01 Cont ID  
Sent By jleahy Date 2020-07-01 Time 17:12 Rev Time 0.00
Received By jleahy Date 2020-06-23 Time 10:55 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2020-07-16 Cont ID  
Sent By lmarchan Date 2020-07-16 Time 08:36 Rev Time 0.00
Received By lmarchan Date 2020-07-15 Time 14:32 Sent To  
Notes
2020-07-16 08:36:24NO FEES DUE PER IMPACT OFFICE.
2020-07-15 14:32:457/15/20 SENT TO IMPACT FEE OFFICE FOR REVIEW. LEM

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2020-06-29 Cont ID  
Sent By jwitmer Date 2020-06-29 Time 13:25 Rev Time 0.00
Received By jwitmer Date 2020-06-29 Time   Sent To  
Notes
2020-06-29 13:19:05IMPACT FEES - DIGITAL SUBMITTALS:
 PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECT DOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON
 APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO
 YOUR PROJECT OR EMAIL IT TO [email protected] .
 PALM BEACH COUNTY IMPACT FEE OFFICE IS LOCATED AT 2300
 N. JOG RD. ROOM?S 2W01-2W14 WEST PALM BEACH, FL.
  

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 2 Status P Date 2020-07-13 Cont ID  
Sent By jwitmer Date 2020-07-13 Time 17:38 Rev Time 0.00
Received By jwitmer Date 2020-07-13 Time 16:59 Sent To  
Notes
2020-07-13 17:28:19NO FLOOD ZONE CERTIFICATE IS REQUIRED, THIS STRUCTURE
 IS A OPEN PAVILION, ROOFED OPEN PAVILION POST ONLY NO
 WALLS.
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 1 Status F Date 2020-06-29 Cont ID  
Sent By jwitmer Date 2020-06-29 Time 13:24 Rev Time 0.00
Received By jwitmer Date 2020-06-29 Time   Sent To  
Notes
2020-06-29 13:22:531A) THE GRADING PLAN INDICATES THE FLOOR ELEVATION OF
 THE EXISTING BUILDING AT 12.08 FEET. THE PLAN DOES NOT
 INDICATE IF THIS ELEVATION IS IN NGVD OR NAVD88? THE
 NEW PAVILION FINISH FLOOR ELEVATION IS NOT GIVEN. )
 BOTH BUILDINGS ARE IN AN AE FLOOD ZONE.
  
 1B) ARTICLE XVII ORDINANCES ARTICLE XVII FLOOD
 PREVENTION & CONTROL.
 FBC BUILDING 1612 AND CITY OF WPB CODE OF SECTION
 94-546. STRUCTURE IS LOCATED IN AN "A" FLOOD ZONE. A
 FLOOD ELEVATION CERTIFICATE WILL BE REQUIRED. PLEASE
 REVIEW CITY ORDINANCE FOR THE CITY REQUIREMENTS REQUIRE
 AN ADDITIONAL 6 INCHES/ (12 INCHES OF ELEVATION IF
 PERMIT APPLICATION AFTER SEPT. 12/2016,
 AFTER OCT. 11/ 2017 AN ADDITIONAL ONE FOOT OF FREE
 BOARD WILL BE REQUIRED OR (2) FEET ABOVE BASE FLOOD.
 AFTER OCT. 11/ 2017 THE BUILDING DEPARTMENT WILL HAVE
 ADOPTED THE NEW FLOOD MAPS AND ALSO IN TOUGHS MAPS THE
 NAVD 88 ELEVATIONS. YOU CAN GO TO THE WEBSITE:
 WWW.NGS.NOAA.GOV/TOOLS/VERTCON/VERTCON.HTML FOR
 CONVERSIONS.
  
 1C) DURING THE PERMITTING OF THIS STRUCTURE THERE WILL
 BE REQUIRED (3) DIFFERENT FLOOD ZONE CERTIFICATES
 REQUIRED:
 (1) A FLOOD ZONE CERTIFICATE IS REQUIRED AS PART OF THE
 PLAN REVIEW DOCUMENTS WITH THE PROPOSED FINISH FLOOR
 HEIGHT. W. P. B. ADMINISTRATIVE CODE 107.3.5.1.1
 BUILDING MINIMUM PLAN REVIEW CRITERIA FOR COMMERCIAL
 BUILDINGS. ( 8) FLOOD REQUIREMENTS ELEVATIONS,
 ENCLOSURES, FLOOD DAMAGE-RESISTANT MATERIALS.
 (2) ONCE THE FIRST FLOOR SLAB IS POURED THE 2ND
 ELEVATION CERTIFICATE IS REQUIRED. W. P. B.
 ADMINISTRATIVE CODE 110.3 REQUIRED INSPECTIONS 1.2
 FLOOR/ SLAB INSPECTION. IN FLOOD HAZARD AREAS, UPON
 PLACEMENT OF THE LOWEST FLOOR, INCLUDING BASEMENT, AND
 PRIOR TO FURTHER VERTICAL CONSTRUCTION, THE ELEVATION
 CERTIFICATION, REQUIRED IN SECTION 1612.5, SHALL BE
 SUBMITTED TO THE BUILDING OFFICIAL.
  
 (2) BEFORE THE ISSUANCE OF A CERTIFICATE OF OCCUPANCY
 OR A CERTIFICATE OF COMPLETION THE 3RD FLOOD ZONE
 CERTIFICATE IS REQUIRED WITH THE HEIGHT OF ALL EXTERIOR
 ATTENDANTS A/C PADS OR OTHER SLABS FOR GENERATORS.
 W. P. B. ADMINISTRATIVE CODE 110.3 REQUIRED INSPECTIONS
 (6) FINAL INSPECTION. TO BE MADE AFTER THE BUILDING IS
 COMPLETED AND READY FOR OCCUPANCY. 6.1. LOWEST FLOOR
 ELEVATION. IN FLOOD HAZARD AREAS, AS PART OF THE FINAL
 INSPECTION, A FINAL CERTIFICATION OF THE LOWEST FLOOR
 ELEVATION SHALL BE SUBMITTED TO THE AUTHORITY HAVING
 JURISDICTION.
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2020-07-13 Cont ID  
Sent By jwitmer Date 2020-07-13 Time 17:30 Rev Time 0.00
Received By jwitmer Date 2020-07-13 Time 17:02 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2020-07-01 Cont ID  
Sent By jleahy Date 2020-07-01 Time 17:12 Rev Time 0.00
Received By jleahy Date 2020-07-01 Time 17:11 Sent To  
Notes
2020-07-01 17:12:43PLAN IS NOT DIGITALLY SIGNED BY THE DESIGNER OF RECORD
  
 PLAN IS REQUIRED TO BE SIGNED AND SEALED BY A DESIGN
 PROFESSIONAL OR THE ELECTRICAL CONTRACTOR QUALIFIER. FS
 471.003(2)(H); 471.025; FBC 107.2.1
  

Review Stop Z ZONING
Rev No 2 Status P Date 2020-07-15 Cont ID  
Sent By jroach Date 2020-07-15 Time 14:31 Rev Time 0.00
Received By jroach Date 2020-07-15 Time 14:31 Sent To  
Notes
2020-07-15 14:31:56ZONING PLAN REVIEW
 ________________________________________
  
 DATE OF REVIEW: 07.15.2020
 PERMIT NO.: 20060784
 ________________________________________
  
 REVIEW STATUS: PASSED WITH PROVISOS
 ________________________________________
  
 THIS REVIEW HAS BEEN PASSED SUBJECT TO THE FOLLOWING
 PROVISOS:
  
 1. SCOPE OF THIS PERMIT IS LIMITED TO THE PAVILION
 ONLY! SEPARATE PERMITS REQUIRED FOR LANDSCAPING,
 IRRIGATION, ETC.
 ________________________________________
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 ________________________________________
  
 QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING:
  
 JOHN P. ROACH, AICP, PRINCIPAL PLANNER
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION
 401 CLEMATIS STREET - P.O. BOX 3147
 WEST PALM BEACH, FLORIDA 33402
  
 P: 561.822.1448
 TTY: 800.955.8771
 E: [email protected]
  
 W: WPB.ORG
  

Review Stop Z ZONING
Rev No 1 Status P Date 2020-06-25 Cont ID  
Sent By jroach Date 2020-06-25 Time 14:56 Rev Time 0.00
Received By jroach Date 2020-06-25 Time 14:56 Sent To  
Notes
***NONE***