Plan Review Details - Permit 20060761
Plan Review Stops For Permit 20060761 |
Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
Rev No |
2 |
Status |
F |
Date |
2021-08-25 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2021-08-25 |
Time |
13:41 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2021-08-25 |
Time |
13:41 |
Sent To |
|
|
Notes |
2021-08-25 13:44:40 | NOT RESOLVED. A SIGNED ACKNOWLEDGEMENT FROM THE | | CONTRACTOR ON LETTERHEAD IS REQUIRED. SEE COMMENT FROM | | FIRST REVIEW THAT FOLLOWS. | | | | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | CONTRACTOR, ON LETTERHEAD, STATING THAT THE | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | COUNTY WILL BE FOLLOWED AND THAT NOTIFICATION WILL BE | | GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS | | REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE: | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | RENOVATION.HTML | | | | |
|
|
Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
Rev No |
1 |
Status |
F |
Date |
2020-07-17 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2020-07-17 |
Time |
14:30 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2020-07-17 |
Time |
14:30 |
Sent To |
|
|
Notes |
2020-07-17 14:34:52 | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | CONTRACTOR, ON LETTERHEAD, STATING THAT THE | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | COUNTY WILL BE FOLLOWED AND THAT NOTIFICATION WILL BE | | GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS | | REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE: | | | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | RENOVATION.HTML | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2021-08-27 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2021-08-27 |
Time |
15:13 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2021-08-25 |
Time |
10:25 |
Sent To |
|
|
Notes |
2021-08-27 14:40:36 | 2ND REVIEW FBC-2017 BUILDING | | PERMIT- 20060761 | | 8/27/2021 | | | | CODES IN EFFECT: | | FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017 | | FBC ACC- FLORIDA ACCESSIBILITY CODE SIXTH ADDITION 2017 | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | 2017 | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | 2017 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2017 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) [NOT RESOLVED.] THE PLANS THAT WERE SUBMITTED ONLY | | HAVE A FEW DIMENSIONS ON THEM. SUBMIT DRAWINGS WITH ALL | | DIMENSIONS SPECIFIED ON THEM. FBC 107.2.1 | | | | 2) [NOT RESOLVED.] SPECIFY THE EXISTING OCCUPANCY TYPE | | FOR THIS SPACE ON THE PLANS. FBC 107.2.1 | | | | 3) [THIS WILL BE A PROVISO TO BE VERIFIED BY THE FIELD | | INSPECTOR.] VERIFY THAT THE TENANT SEPARATION WALLS ON | | EACH SIDE OF THE SPACE ARE 2 HOUR FIRE RESISTIVE RATED. | | FBC 706 | | | | 4) [NOT RESOLVED. THE CONSTRUCTION TYPE IS SPECIFIED AS | | TYPE IV ON THE PLANS IN THE CITY'S RECORDS. THE PLANS | | FOR THE BUILDING HAS NON-COMBUSTIBLE FLOORS, BEARING | | WALLS, AND ROOF CONSTRUCTION. THE CONSTRUCTION TYPES IN | | THE BUILDING CODES HAVE CHANGED SINCE THIS BUILDING WAS | | CONSTRUCTED. BASED ON THE 2017 FBC THE CONSTRUCTION | | TYPE FOR THIS BUILDING IS TYPE II-B. PLEASE CHANGE THE | | CONSTRUCTION TYPE ON THE PLANS FROM V-B TO II-B.] THE | | TYPE OF CONSTRUCTION FOR THIS BUILDING IS SPECIFIED AS | | TYPE V ON SHEET LS.100. SPECIFY IF IT IS TYPE V-A OR | | V-B CONSTRUCTION. BASED ON MY RESEARCH THIS SPACE IS | | LOCATED IN A 14,400 SQUARE FOOT WAREHOUSE BUILDING. IT | | IS LOCATED IN BUILDING #4 IN A GROUP OF OTHER WAREHOUSE | | BUILDINGS. THE ORIGINAL OCCUPANCY WAS BUSINESS AND | | WAREHOUSE. IT DOES NOT APPEAR THAT THIS BUILDING IS | | TYPE V CONSTRUCTION. PLEASE VERIFY THE CONSTRUCTION | | TYPE. FBC 601 | | | | 5) [RESOLVED.] ONE SHEET LS.100 YOU HAVE INCLUDED THE | | CELLAR AND BAR SERVICE AREAS WITH THE F-2 OCCUPANCY. IT | | APPEARS THAT THE BAR SERVICE AREA AND POSSIBLY THE | | CELLAR AREA SHOULD BE INCLUDED WITH THE A2 OCCUPANCY. | | PLEASE CLARIFY THE INTENDED USE OF THE CELLAR. EXPLAIN | | WHY THE BAR SERVICE AREA AND THE CELLAR SHOULD NOT BE | | PART OF THE ASSEMBLY AREA. | | | | 6) [RESOLVED.] THE SECTION THAT ALLOWS ASSEMBLY AREAS | | WITH AN OCCUPANT LOAD OF LESS THAN 50 PERSONS TO BE | | CLASSIFIED AS A GROUP B OCCUPANCY DOES NOT ALLOW THE | | OCCUPANT LOAD FOR THE ASSEMBLY AREA TO BE RECALCULATED | | USING THE OCCUPANT LOAD FACTOR FOR A BUSINESS | | OCCUPANCY. THE NUMBER OF OCCUPANTS STAYS THE SAME AS | | CALCULATED FOR AN ASSEMBLY AREA. PLEASE CORRECT. FBC | | 1004 & FBC 303.1.1 SMALL BUILDINGS AND TENANT SPACES A | | BUILDING OR TENANT SPACE USED FOR ASSEMBLY PURPOSES | | WITH AN OCCUPANT LOAD OF LESS THAN 50 PERSONS SHALL BE | | CLASSIFIED AS A GROUP B OCCUPANCY. | | | | 7) [NOT RESOLVED. THE RESPONSE LETTER STATES THAT THIS | | IS A NON-SEPARATED MIXED USE OCCUPANCY. SPECIFY THIS ON | | THE PLANS AND REMOVE THE STATEMENT ON SHEET ON SHEET | | LS.100 THAT SPECIFIES THAT THE ASSEMBLY OCCUPANCY IS | | ACCESSORY TO THE F-2 OCCUPANCY.] FBC 508.2.3 STATES | | THAT AGGREGATE ACCESSORY OCCUPANCIES SHALL NOT OCCUPY | | MORE THAN 10 PERCENT OF THE FLOOR AREA OF THE STORY IN | | WHICH THEY ARE LOCATED. SINCE THE FLOOR AREA OF THE | | ASSEMBLY AREAS IS MORE THAN 10 PERCENT THIS CAN NOT BE | | AN ACCESSORY OR ANCILLARY OCCUPANCY. THIS IS A MIXED | | USE OCCUPANCY. YOU WILL NEED TO DETERMINE IF IT WILL BE | | A NON-SEPARATED OCCUPANCY OR A SEPARATED OCCUPANCY PER | | FBC508.3 OR 508.4. | | | | 8) [NOT RESOLVED. CHANGE THIS TO SPECIFY 2017 FBC | | SECTION 1006.2.] ON SHEET LS.100 UNDER EGRESS | | REQUIREMENTS THE NUMBER OF REQUIRED EXITS SPECIFIES FBC | | 2014 SECTION 1021.2(2). PLEASE CORRECT THIS TO | | REFERENCE THE 2017 FBC AND THE APPROPRIATE SECTION. | | | | FLORIDA ACCESSIBILITY COMMENTS : THIS IS A CHANGE OF | | OCCUPANCY AND IS TREATED AS NEW CONSTRUCTION FOR THE | | APPLICATION OF ACCESSIBILITY REQUIREMENTS. FBC EXISTING | | BUILDING 1006.1 GENERAL. ACCESSIBILITY IN PORTIONS OF | | BUILDINGS UNDERGOING A CHANGE OF OCCUPANCY | | CLASSIFICATION SHALL COMPLY WITH THE PROVISIONS OF THE | | FLORIDA BUILDING CODE, ACCESSIBILITY. | | | | 9) [ NOT RESOLVED. PROVIDE A COST BREAKDOWN TO SHOW HOW | | THE 20% DISPROPORTIONATE COSTS WILL BE SPENT TOWARD | | IMPROVING ACCESSIBILITY.] SHOW ACCESSIBLE PARKING | | SPACES, ACCESSIBLE ROUTE TO ACCESSIBLE ENTRANCE AND | | THROUGH PRIMARY SERVICE AREA. FBC - ACCESSIBILITY 206 | | AND 208 | | | | 10) [NOT RESOLVED. PROVIDE DETAILED DRAWINGS, | | ELEVATIONS, ETC. TO SHOW THAT THE BATHROOMS COMPLY WITH | | ACCESSIBILITY.] SHOW THAT BATHROOMS MEET ACCESSIBILITY | | REQUIREMENTS. 603 TOILET AND BATHING ROOMS. 603.1 | | GENERAL. TOILET AND BATHING ROOMS SHALL COMPLY WITH 603 | | | | 11) [NOT RESOLVED. THE RESPONSE LETTER STATES THAT THE | | BAR TOP WILL BE USED FOR BEVERAGE SERVICE AND THE FLOOR | | PLAN SHOWS SEATING AT THE BAR TOP. THIS BAR IS NEW | | CONSTRUCTION AND IT WILL HAVE TO COMPLY WITH | | ACCESSIBILITY.] SHOW ACCESSIBLE AREAS AT THE BARS. FBC | | - ACCESSIBILITY 226.1 GENERAL. WHERE DINING SURFACES | | ARE PROVIDED FOR THE CONSUMPTION OF FOOD OR DRINK, AT | | LEAST 5 PERCENT OF THE SEATING SPACES AND STANDING | | SPACES AT THE DINING SURFACES SHALL COMPLY WITH 902. IN | | ADDITION, WHERE WORK SURFACES ARE PROVIDED FOR USE BY | | OTHER THAN EMPLOYEES, AT LEAST 5 PERCENT SHALL COMPLY | | WITH 902. | | | | 12) [RESOLVED.] SHOW ACCESSIBLE SEATING DISPERSED | | THROUGHOUT TASTING AREAS. FBC - A 226.2 DISPERSION. | | DINING SURFACES AND WORK SURFACES REQUIRED TO COMPLY | | WITH 902 SHALL BE DISPERSED THROUGHOUT THE SPACE OR | | FACILITY CONTAINING DINING SURFACES AND WORK SURFACES. | | | | 13) [ NOT RESOLVED. THE BAR TOP WILL BE USED AS A | | SERVICE COUNTER AND WILL HAVE TO COMPLY WITH FBC | | ACCESSIBILITY.] SHOW THAT THE SALES/SERVICE COUNTER | | COMPLIES WITH ACCESSIBILITY. FBC - A 904.4 SALES AND | | SERVICE COUNTERS. SALES COUNTERS AND SERVICE COUNTERS | | SHALL COMPLY WITH 904.4.1 OR 904.4.2. THE ACCESSIBLE | | PORTION OF THE COUNTER TOP SHALL EXTEND THE SAME DEPTH | | AS THE SALES OR SERVICE COUNTER TOP. | | | | 14) NEW COMMENT.THE TOTAL NUMBER OF OCCUPANTS IS | | SPECIFIED AS 46.2 PERSONS ON SHEET LS.100. SINCE THERE | | CAN NOT BE A FRACTION OF A PERSON, THE TOTAL NEEDS TO | | BE ROUNDED UP TO THE NEXT HIGHER WHOLE NUMBER WHICH IS | | 47 PERSONS. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2020-07-22 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2020-07-22 |
Time |
09:51 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2020-07-16 |
Time |
06:51 |
Sent To |
|
|
Notes |
2020-07-14 12:07:13 | 1ST REVIEW FBC-2017 BUILDING | | PERMIT- 20060761 | | 7/21/2020 | | | | CODES IN EFFECT: | | FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017 | | FBC ACC- FLORIDA ACCESSIBILITY CODE SIXTH ADDITION 2017 | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | 2017 | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | 2017 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2017 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) THE PLANS THAT WERE SUBMITTED ONLY HAVE A FEW | | DIMENSIONS ON THEM. SUBMIT DRAWINGS WITH ALL DIMENSIONS | | SPECIFIED ON THEM. FBC 107.2.1 | | | | 2) SPECIFY THE EXISTING OCCUPANCY TYPE FOR THIS SPACE | | ON THE PLANS. FBC 107.2.1 | | | | 3) VERIFY THAT THE TENANT SEPARATION WALLS ON EACH SIDE | | OF THE SPACE ARE 2 HOUR FIRE RESISTIVE RATED. FBC 706 | | | | 4) THE TYPE OF CONSTRUCTION FOR THIS BUILDING IS | | SPECIFIED AS TYPE V ON SHEET LS.100. SPECIFY IF IT IS | | TYPE V-A OR V-B CONSTRUCTION. BASED ON MY RESEARCH THIS | | SPACE IS LOCATED IN A 14,400 SQUARE FOOT WAREHOUSE | | BUILDING. IT IS LOCATED IN BUILDING #4 IN A GROUP OF | | OTHER WAREHOUSE BUILDINGS. THE ORIGINAL OCCUPANCY WAS | | BUSINESS AND WAREHOUSE. IT DOES NOT APPEAR THAT THIS | | BUILDING IS TYPE V CONSTRUCTION. PLEASE VERIFY THE | | CONSTRUCTION TYPE. FBC 601 | | | | 5) ONE SHEET LS.100 YOU HAVE INCLUDED THE CELLAR AND | | BAR SERVICE AREAS WITH THE F-2 OCCUPANCY. IT APPEARS | | THAT THE BAR SERVICE AREA AND POSSIBLY THE CELLAR AREA | | SHOULD BE INCLUDED WITH THE A2 OCCUPANCY. PLEASE | | CLARIFY THE INTENDED USE OF THE CELLAR. EXPLAIN WHY THE | | BAR SERVICE AREA AND THE CELLAR SHOULD NOT BE PART OF | | THE ASSEMBLY AREA. | | | | 6) THE SECTION THAT ALLOWS ASSEMBLY AREAS WITH AN | | OCCUPANT LOAD OF LESS THAN 50 PERSONS TO BE CLASSIFIED | | AS A GROUP B OCCUPANCY DOES NOT ALLOW THE OCCUPANT LOAD | | FOR THE ASSEMBLY AREA TO BE RECALCULATED USING THE | | OCCUPANT LOAD FACTOR FOR A BUSINESS OCCUPANCY. THE | | NUMBER OF OCCUPANTS STAYS THE SAME AS CALCULATED FOR AN | | ASSEMBLY AREA. PLEASE CORRECT. FBC 1004 & FBC 303.1.1 | | SMALL BUILDINGS AND TENANT SPACES A BUILDING OR TENANT | | SPACE USED FOR ASSEMBLY PURPOSES WITH AN OCCUPANT LOAD | | OF LESS THAN 50 PERSONS SHALL BE CLASSIFIED AS A GROUP | | B OCCUPANCY. | | | | 7) ON SHEET LS.100 IT IS STATED THAT THE ASSEMBLY | | OCCUPANCY IS ACCESSORY TO THE F-2 OCCUPANCY. FBC | | 508.2.3 STATES THAT AGGREGATE ACCESSORY OCCUPANCIES | | SHALL NOT OCCUPY MORE THAN 10 PERCENT OF THE FLOOR AREA | | OF THE STORY IN WHICH THEY ARE LOCATED. SINCE THE FLOOR | | AREA OF THE ASSEMBLY AREAS IS MORE THAN 10 PERCENT THIS | | CAN NOT BE AN ACCESSORY OR ANCILLARY OCCUPANCY. THIS IS | | A MIXED USE OCCUPANCY. YOU WILL NEED TO DETERMINE IF IT | | WILL BE A NON-SEPARATED OCCUPANCY OR A SEPARATED | | OCCUPANCY PER FBC508.3 OR 508.4. | | | | 8) ON SHEET LS.100 UNDER EGRESS REQUIREMENTS THE NUMBER | | OF REQUIRED EXITS SPECIFIES FBC 2014 SECTION 1021.2(2). | | PLEASE CORRECT THIS TO REFERENCE THE 2017 FBC AND THE | | APPROPRIATE SECTION. | | | | FLORIDA ACCESSIBILITY COMMENTS : THIS IS A CHANGE OF | | OCCUPANCY AND IS TREATED AS NEW CONSTRUCTION FOR THE | | APPLICATION OF ACCESSIBILITY REQUIREMENTS. FBC EXISTING | | BUILDING 1006.1 GENERAL. ACCESSIBILITY IN PORTIONS OF | | BUILDINGS UNDERGOING A CHANGE OF OCCUPANCY | | CLASSIFICATION SHALL COMPLY WITH THE PROVISIONS OF THE | | FLORIDA BUILDING CODE, ACCESSIBILITY. | | | | 9) SHOW ACCESSIBLE PARKING SPACES, ACCESSIBLE ROUTE TO | | ACCESSIBLE ENTRANCE AND THROUGH PRIMARY SERVICE AREA. | | FBC - ACCESSIBILITY 206 AND 208 | | | | 10) SHOW THAT BATHROOMS MEET ACCESSIBILITY | | REQUIREMENTS. 603 TOILET AND BATHING ROOMS. 603.1 | | GENERAL. TOILET AND BATHING ROOMS SHALL COMPLY WITH 603 | | | | 11) SHOW ACCESSIBLE AREAS AT THE BARS. FBC - | | ACCESSIBILITY 226.1 GENERAL. WHERE DINING SURFACES ARE | | PROVIDED FOR THE CONSUMPTION OF FOOD OR DRINK, AT LEAST | | 5 PERCENT OF THE SEATING SPACES AND STANDING SPACES AT | | THE DINING SURFACES SHALL COMPLY WITH 902. IN ADDITION, | | WHERE WORK SURFACES ARE PROVIDED FOR USE BY OTHER THAN | | EMPLOYEES, AT LEAST 5 PERCENT SHALL COMPLY WITH 902. | | | | 12) SHOW ACCESSIBLE SEATING DISPERSED THROUGHOUT | | TASTING AREAS. FBC - A 226.2 DISPERSION. DINING | | SURFACES AND WORK SURFACES REQUIRED TO COMPLY WITH 902 | | SHALL BE DISPERSED THROUGHOUT THE SPACE OR FACILITY | | CONTAINING DINING SURFACES AND WORK SURFACES. | | | | 13) SHOW THAT THE SALES/SERVICE COUNTER COMPLIES WITH | | ACCESSIBILITY. FBC - A 904.4 SALES AND SERVICE | | COUNTERS. SALES COUNTERS AND SERVICE COUNTERS SHALL | | COMPLY WITH 904.4.1 OR 904.4.2. THE ACCESSIBLE PORTION | | OF THE COUNTER TOP SHALL EXTEND THE SAME DEPTH AS THE | | SALES OR SERVICE COUNTER TOP. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2021-08-09 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2021-08-09 |
Time |
11:22 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2021-08-09 |
Time |
11:17 |
Sent To |
|
|
Notes |
2021-08-09 11:25:26 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | FLORIDA BUILDING CODE 2017 6TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | NFPA 70 2014 EDITION | | | | JAKE LEAHY BN, BU, PX | | ELECTRICAL PLANS EXAMINER II | | 561-805-6713 | | [email protected] | | | | IF A CHANGE OF OCCUPANY IS BEING REQUESTED THIS ALL | | COULD NOT HAVE BEEN EXISTING, | | | | PLEASE INDICATE ON THE PLANS THE NEW ELECTRICAL WORK | | FOR THE BREWING EQUIPMENT. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2020-07-08 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2020-07-08 |
Time |
12:00 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2020-07-08 |
Time |
11:54 |
Sent To |
|
|
Notes |
2020-07-08 12:01:13 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | JAKE LEAHY | | ELECTRICAL PLANS EXAMINER II | | 561-805-6713 | | [email protected] | | | | NO ELECTRICAL LAYOUT OF FLOOR AREA OUTLETS, | | EQUIPMENT(ELECTRIC) LIGHTING |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
F |
Date |
2021-07-30 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2021-07-30 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2021-07-30 |
Time |
14:50 |
Sent To |
|
|
Notes |
2021-07-30 14:50:51 | 1) SHEET LS .100 - THERE IS NO INDICATION OF WHETHER | | THIS IS A MIXED OR SEPARATED OCCUPANCY. | | | | THERE IS AN INDICATION THAT THE ASSEMBLY AREA IS | | ACCESSORY; HOWEVER, PER NFPA 101, IT DOES NOT APPEAR TO | | BE ACCESSORTY. | | | | PER NFPA 101 | | | | PER TABLE 6.1.14.4.1 (B) | | | | THE REQUIRED SEPARATION OF AN INDUSTRIAL GENERAL | | HAZARD/SPECIAL HAZARD AND MERCANTILE/ASSEMBLY IS 2 | | HOURS. | | | | IS THE FIRE CODE REQUIREMENT IS MORE | | RESTRICTIVE/STRINGENT THAN THE BUILDING CODE CITED, | | THEN THE FIRE CODE APPLIES. | | | | A 2 HOUR FIRE RATED SEPARATION IS REQUIRED. | | | | PLEASE REVIEW AND PROVIDE DETAILS AND FOR THE REQUIRED | | SEPARATION. | | | | | | | | 2) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | RE-SUBMITTAL OF THE ABOVE. | | | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2020-06-25 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2020-06-25 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2020-06-22 |
Time |
12:59 |
Sent To |
|
|
Notes |
2020-06-22 16:17:26 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | | | 1) SHEET LS .100 - THERE IS NO INDICATION OF WHETHER | | THIS IS A MIXED OR SEPARATED OCCUPANCY. | | | | THERE IS AN INDICATION THAT THE ASEMBLY AREA IS | | ACCESSORY; HOWEVER, PER NFPA 101, IT DOES NOT APPEAR TO | | BE ACCESSORTY. | | | | PER NFPA 101 | | | | 6.1 CLASSIFICATION OF OCCUPANCY. | | 6.1.1 GENERAL. | | 6.1.1.1 OCCUPANCY CLASSIFICATION. THE OCCUPANCY OF A | | BUILDING OR | | STRUCTURE, OR PORTION OF A BUILDING OR STRUCTURE, SHALL | | BE CLASSIFIED IN | | ACCORDANCE WITH 6.1.2 THROUGH 6.1.13. OCCUPANCY | | CLASSIFICATION SHALL BE | | SUBJECT TO THE RULING OF THE AUTHORITY HAVING | | JURISDICTION WHERE THERE IS A | | QUESTION OF PROPER CLASSIFICATION IN ANY INDIVIDUAL | | CASE. | | | | 6.1.14 MULTIPLE OCCUPANCIES. | | 6.1.14.1 GENERAL. | | 6.1.14.1.1 MULTIPLE OCCUPANCIES SHALL COMPLY WITH THE | | REQUIREMENTS OF | | 6.1.14.1 AND ONE OF THE FOLLOWING: | | (1) MIXED OCCUPANCIES ? 6.1.14.3 | | (2) SEPARATED OCCUPANCIES ? 6.1.14.4 | | | | 6.1.14.1.2 WHERE EXIT ACCESS FROM AN OCCUPANCY | | TRAVERSES ANOTHER | | OCCUPANCY, THE MULTIPLE OCCUPANCY SHALL BE TREATED AS A | | MIXED | | OCCUPANCY. | | 6.1.14.1.3* WHERE INCIDENTAL TO ANOTHER OCCUPANCY, | | AREAS USED AS | | FOLLOWS SHALL BE PERMITTED TO BE CONSIDERED PART OF THE | | PREDOMINANT | | OCCUPANCY AND SHALL BE SUBJECT TO THE PROVISIONS OF THE | | CODE THAT APPLY | | TO THE PREDOMINANT OCCUPANCY: | | (1) MERCANTILE, BUSINESS, INDUSTRIAL, OR STORAGE USE | | (2) *NONRESIDENTIAL USE WITH AN OCCUPANT LOAD FEWER | | THAN THAT | | ESTABLISHED BY SECTION 6.1 FOR THE OCCUPANCY THRESHOLD | | (3) PORTIONS OF BUILDINGS USED AS ACCESSORY OFFICES OR | | FOR CUSTOMARY | | NON-HAZARDOUS USES NECESSARY FOR TRANSACTING THE | | PRINCIPAL | | BUSINESS IN STORAGE AND INDUSTRIAL OCCUPANCIES NEED NOT | | BE | | SEPARATED FROM THE PRINCIPAL USE. | | (4) INDUSTRIAL OCCUPANCIES PRODUCING, USING, OR STORING | | LOW HAZARD | | PRODUCTS IN ACCORDANCE WITH SUBDIVISION 6.2.2 NEED NOT | | BE | | SEPARATED BY FIRE-RESISTANT CONSTRUCTION FROM THE | | OCCUPANCIES TO | | WHICH THEY ARE ACCESSORY. | | 6.1.14.1.3.1 INCIDENTAL USE AREAS SHALL BE SEPARATED AS | | REQUIRED BY TABLE | | 508.2.5 OF THE FLORIDA BUILDING CODE WHERE TABLE | | 508.2.5 PERMITS AN | | AUTOMATIC FIRE-EXTINGUISHING SYSTEM WITHOUT A FIRE | | BARRIER, THE INCIDENTAL | | USE AREA SHALL BE SEPARATED BY CONSTRUCTION CAPABLE OF | | RESISTING THE | | PASSAGE OF SMOKE. | | 6.1.14.1.4 THE FOLLOWING ACCESSORY OCCUPANCIES SHALL | | NOT BE REQUIRED TO | | BE SEPARATED FROM THE PRIMARY OCCUPANCY AS REQUIRED IN | | 6.1.14.4: | | (1) A KITCHEN IN AN ASSEMBLY OCCUPANCY DOES NOT | | CONSTITUTE A MIXED | | OCCUPANCY. | | (2) ACCESSORY USES IN INDUSTRIAL AND STORAGE | | OCCUPANCIES AS OTHERWISE | | PROVIDED IN 6.1.14.1.3(1) | | (3) ROOMS OR SPACES USED FOR CUSTOMARY STORAGE OF | | NON-HAZARDOUS | | MATERIALS IN ASSEMBLY, BUSINESS, EDUCATIONAL, | | INDUSTRIAL, | | MERCANTILE, HOTEL AND DORMITORY, AND APARTMENT | | OCCUPANCIES WHICH | | IN AGGREGATE DO NOT EXCEED 10% OF THE MAJOR FLOOR AREA | | IN WHICH | | THEY ARE LOCATED. PROTECTION FROM HAZARDS SHALL BE AS | | OTHERWISE | | PROVIDED IN THE SPECIFIC OCCUPANCY CHAPTER | | | | | | 6.2.1.3* FOR THE PURPOSE OF THIS CODE, WHERE DIFFERENT | | DEGREES OF | | HAZARD OF CONTENTS EXIST IN DIFFERENT PARTS OF A | | BUILDING OR STRUCTURE, | | THE MOST HAZARDOUS SHALL GOVERN THE CLASSIFICATION, | | UNLESS | | HAZARDOUS AREAS ARE SEPARATED OR PROTECTED AS SPECIFIED | | IN SECTION | | 8.7 AND THE APPLICABLE SECTIONS OF CHAPTERS 11 THROUGH | | 43. | | | | | | PLEASE REVIEW AND PROVIDE DETAILS AND FOR THE REQUIRED | | SEPARATION. | | | | | | | | 1A) SHEET A.100 - THE TASTING ROOM APPEARS TO BE MORE | | OF A BAR THAN A ROOM IS MORE THAN INCIDENTAL TO THE | | OCCUPANCY. | | | | PER NFPA 101, TABLE 6.1.14.4.1(B) A 2 HOUR SEPARATION | | IS REQUIRED | | | | 6.2.1.3* FOR THE PURPOSE OF THIS CODE, WHERE DIFFERENT | | DEGREES OF | | HAZARD OF CONTENTS EXIST IN DIFFERENT PARTS OF A | | BUILDING OR STRUCTURE, | | THE MOST HAZARDOUS SHALL GOVERN THE CLASSIFICATION, | | UNLESS | | HAZARDOUS AREAS ARE SEPARATED OR PROTECTED AS SPECIFIED | | IN SECTION | | 8.7 AND THE APPLICABLE SECTIONS OF CHAPTERS 11 THROUGH | | 43. | | | | PLEASE REVIEW AND CORRECT. | | | | | | | | | | 2) SHEET S 7 OF 8 - FERMENTOR CO2 VENT SYSTEM - THERE | | IS AN INDICATION OF A VENTING SYSTEM THAT INDICATES | | GOING UNDER A BAY DOOR. | | | | THERE NEEDS TO BE A BETTER PLAN OF VENTING TO THE | | OUTSIDE AND ONE THAT HELPS DISPERSE THE CO2 FROM | | NEIGBORING BUSINESSES. | | | | | | PLEASE PROVIDE DETAILS. | | | | | | | | 2A) THERE DOES NOT APPEAR TO AN INDICATION OF THE | | VENTING MATERIAL AND HOW IT WILL BE SUPPORTED. | | | | PLEASE PROVIDE DETAILS. | | | | | | | | 2B) THERE DOES NOT APPEAR TO BE ANY CO2 DETECTION | | DEVICES THROUGHOUT THE OCCUPANCY. | | | | AS A INDUSTRIAL THAT PRODUCES CO2 AS PART OF ITS | | PROCESSES CO2 DETECTION IS REQUIRED FOR LIFE SAFETY | | PURPOSES. INSTALLATION OF CO2 AND O2 ALARMS MAY BE | | REQUIRED. | | | | PLEASE REVIEW AND CORECT. | | | | | | | | 2C) FOR CONFIRMATION PURPOSES, THERE DOES NOT APPEAR TO | | BE ANY CO2 STORAGE BOTTLES/CONTAINORS WITHIN IN THE | | OCCUPANCY THAT COULD BE USED DURING THE BREWING | | PROCESS. | | | | PLEASE CONFIRM THAT CO2 STORAGE TANKS WILL NOT BE USED. | | | | | | | | | | 3) ELECTRICAL DEVICES/EQUIPMENT - IN BREWERIES THERE | | CAN BE COMBUSTIBLE DUST CREATED DUE TO SEVRAL PROCESSED | | THAT MAY ACCULMULATE ON SURFACES AND IN THE AIR. | | | | IT IS IMPORTANT TO HAVE INTRINSICALY SAFE ELCTRICAL | | DEVICES/EQUIPMENT IN THESE AREAS. | | | | PLEASE REVIEW AND PROVIDE PROPER ELECTRICAL EQUIPMENT. | | | | PER NFPA 654 | | 6.5 ELECTRICAL EQUIPMENT. | | 6.5.1 ALL ELECTRICAL EQUIPMENT AND INSTALLATIONS SHALL | | COMPLY | | WITH THE REQUIREMENTS OF NFPA 70, NATIONAL ELECTRICAL | | CODE, OR | | NFPA 496, STANDARD FOR PURGED AND PRESSURIZED | | ENCLOSURES FOR ELECTRICAL | | EQUIPMENT. | | 6.5.2* IN LOCAL AREAS OF A PLANT WHERE A HAZARDOUS | | QUANTITY OF | | DUST ACCUMULATES OR IS SUSPENDED IN AIR, THE AREA SHALL | | BE CLASSIFIED | | AND ALL ELECTRICAL EQUIPMENT AND INSTALLATIONS IN THOSE | | LOCAL AREAS SHALL COMPLY WITH ARTICLE 502 OR ARTICLE | | 503 OF | | NFPA 70, NATIONAL ELECTRICAL CODE, AS APPLICABLE. | | | | I. GENERAL | | 502.1 SCOPE. ARTICLE 502 COVERS THE REQUIREMENTS FOR | | ELECTRICAL | | AND ELECTRONIC EQUIPMENT AND WIRING FOR ALL VOLTAGES | | IN CLASS II, DIVISION 1 AND 2 LOCATIONS WHERE FIRE OR | | EXPLOSION | | HAZARDS MAY EXIST DUE TO COMBUSTIBLE DUST. | | | | | | | | 4) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | ABOVE. | | | | | | 5) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | RE-SUBMITTAL OF THE ABOVE. | | | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2021-08-27 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2021-08-27 |
Time |
15:14 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2021-07-29 |
Time |
09:32 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2020-07-22 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2020-07-22 |
Time |
09:52 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2020-06-19 |
Time |
09:09 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2020-07-17 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2020-07-17 |
Time |
14:23 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2020-07-17 |
Time |
14:23 |
Sent To |
|
|
Notes |
2020-07-17 14:25:01 | THIS IS A CHANGE OF OCCUPANCY WHICH IS REQUIRED TO BE | | REVIEWED FOR IMPACT FEES. PLANS WILL BE REVIEWED BY THE | | PBC IMPACT FEE OFFICE DIGITALLY VIA PROJECTDOX UPON | | NOTIFICATION BY THIS OFFICE. NOTIFICATION MAY OCCUR | | WHEN PLANS ARE NEAREST FINAL FORM. YOU MAY COORDINATE | | WITH THE IMPACT FEE OFFICE AT (561) 233-5025 OR SIMPLY | | UPLOAD THE MUNICIPAL IMPACT FEE QUESTIONNAIRE FORM TO | | YOUR PROJECT AND NAME THE FILE MUNICIPAL IMPACT FEE | | QUESTIONNAIRE. THE FORM CAN BE FOUND AT: | | HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON | | APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO | | YOUR PROJECT OR EMAIL IT TO [email protected] . |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2021-08-18 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2021-08-17 |
Time |
15:59 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2021-08-06 |
Time |
09:28 |
Sent To |
|
|
Notes |
2021-08-17 15:59:47 | 2ND REVIEW FBC-2020 MECHANICAL | | PERMIT-20060761 | | | | CODES IN EFFECT: | | | | FBC B- FLORIDA BUILDING CODE | | FBC M- FLORIDA MECHANICAL CODE | | FBC EC- FLORIDA ENERGY CONSERVATION | | FBC FG- FLORIDA FUEL GAS | | FBC EX- FLORIDA EXISTING BUILDING CODE | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) PLEASE SHOW HOW THE VENTILATION FOR ALL SPACES OF | | THIS TENANT SPACE WILL MEET FBC M 401.3 (VENTILATION | | SHALL BE PROVIDED DURING THE PERIODS THAT THE ROOM OR | | SPACE IS OCCUPIED.) | | | | 2) PLEASE PROVIDE MECHANICAL EQUIPMENT SIZING | | CALCULATIONS BASED ON THE NATURAL VENTILATION OF THE | | CHANGE OF USE OF THE SPACES. FBC EC C403.2.1 | | | | 3) PLEASE ADDRESS ALL OF THE COMMENTS FROM THE 1ST | | CYCLE MECHANICAL REVIEW LISTED BELOW. | | | | | | 1ST REVIEW FBC-2017 MECHANICAL | | PERMIT-20060761 | | | | | | | | 2) PLEASE PROVIDE COMPLETE DRAWINGS OF THE EXISTING | | MECHANICAL SYSTEM AND INCLUDE ANY NEW CHANGES. THIS | | DRAWING MUST SHOW THE RATED WALLS USED AS SEPARATION | | BETWEEN THE NEW OCCUPANCIES WITH DAMPERS IF ANY DUCT | | WORK IS PENETRATING THESE RATED WALLS. FBC FS 107.2.1 | | | | 3) PLEASE PROVIDE VENTILATION CALCULATIONS FOR THIS NEW | | PROJECT, FOR ALL AREAS. THE NATURAL VENTILATION | | CALCULATIONS IN THIS PACKAGE WOULD NOT WORK AS THERE | | SHOULD BE A RATED WALL BETWEEN THE F-2 AND B | | OCCUPANCIES. FBC M 403 | | | | 4) PLEASE PROVIDE QUANTITIES OF INGREDIENTS STORED AT | | THIS FACILITY. FBC FS 107.2.1 | | | | 5) PLEASE SHOW THE EXHAUST FOR THE MASH AREA. FBC FS | | 107.2.1 | | | | 6) PLEASE PROVIDE A VENTING DETAIL FOR THE CO2 TO AN | | APPROVED TERMINATION LOCATION. FBC FS 107.2.1 | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD | | SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER | | SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN | | THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS | | PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS | | PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR | | UPDATED. | | | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2020-07-10 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2020-07-10 |
Time |
09:44 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2020-07-09 |
Time |
15:36 |
Sent To |
|
|
Notes |
2020-07-10 09:45:33 | 1ST REVIEW FBC-2017 MECHANICAL | | PERMIT-20060761 | | | | CODES IN EFFECT: | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | 2017 | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | 2017 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2017 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) PLEASE PROVIDE OCCUPANCY CLASSIFICATION OF EXISTING | | COMMERCIAL SUITE. FBC FS 107.2.1 | | | | 2) PLEASE PROVIDE COMPLETE DRAWINGS OF THE EXISTING | | MECHANICAL SYSTEM AND INCLUDE ANY NEW CHANGES. THIS | | DRAWING MUST SHOW THE RATED WALLS USED AS SEPARATION | | BETWEEN THE NEW OCCUPANCIES WITH DAMPERS IF ANY DUCT | | WORK IS PENETRATING THESE RATED WALLS. FBC FS 107.2.1 | | | | 3) PLEASE PROVIDE VENTILATION CALCULATIONS FOR THIS NEW | | PROJECT, FOR ALL AREAS. THE NATURAL VENTILATION | | CALCULATIONS IN THIS PACKAGE WOULD NOT WORK AS THERE | | SHOULD BE A RATED WALL BETWEEN THE F-2 AND B | | OCCUPANCIES. FBC M 403 | | | | 4) PLEASE PROVIDE QUANTITIES OF INGREDIENTS STORED AT | | THIS FACILITY. FBC FS 107.2.1 | | | | 5) PLEASE SHOW THE EXHAUST FOR THE MASH AREA. FBC FS | | 107.2.1 | | | | 6) PLEASE PROVIDE A VENTING DETAIL FOR THE CO2 TO AN | | APPROVED TERMINATION LOCATION. FBC FS 107.2.1 | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD | | SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER | | SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN | | THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS | | PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS | | PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR | | UPDATED. | | | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2021-08-06 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2021-08-06 |
Time |
15:55 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2021-08-06 |
Time |
10:33 |
Sent To |
|
|
Notes |
2021-08-06 15:55:44 | 2ND REVIEW FBC-2017 PLUMBING | | PERMIT- 20060761 | | 8/6/2021 | | | | CODES IN EFFECT: | | FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017 | | FBC ACC- FLORIDA ACCESSIBILITY CODE SIXTH ADDITION 2017 | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | 2017 | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | 2017 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2017 | | | | PLAN REVIEW RESULTS: DENIED. A NARRATIVE RESPONSE HAS | | BEEN PROVIDED TO THE IST REVIEW PLUMBING COMMENTS, | | HOWEVER THE DOCUMENT WAS NOT SIGNED AND HAD NO REPLY | | INFORMATION PROVIDED. THE NARRATIVE STATES THAT | | PLUMBING PLANS WILL BE UPLOADED SEPARATELY. AS I COULD | | NOT LOCATE THE (P) PLUMBING PLANS, PLEASE CLARIFY IF | | THE PLANS ARE TO BE UPLOADED "SEPARATELY" UNDER A | | SEPARATE PERMIT OR UNDER THIS PERMIT. SHEET A100 | | INDICATES BATH AND BAR FIXTURES AND UNDERSLAB DRAIN | | PIPING AS EXISTING. PLEASE NOTE I HAVE RESEARCHED | | BUILDING DEPARTMENT RECORDS AND WAS UNABLE TO LOCATE A | | PERMIT FOR THE SECOND BATHROOM AND BAR IN THE SPACE. IT | | APPEARS THAT ONE BATHROOM WAS CONSTRUCTED UNDER THE | | MAIN BUILDING PERMIT FOR BUILDING-4 BUT THE RECORD | | PLANS THAT WERE UPLOADED SHOW A SINGLE BATHROOM AND THE | | MAIN DRAIN TO THE NORTH OF THE BATHROOM. SHEET A100 | | SHOWS A SECOND BATHROOM AND THE DRAIN RUNNING SW OF THE | | BATHROOMS. FAILED COMMENTS FROM THE 1ST REVIEW ARE | | LISTED BELOW WITH ADDITONAL NOTES FOR FURTHER | | CLARIFICATION. | | | | 1) FAILED. PROVIDE PLUMBING FIXTURE CALCULATIONS. | | PROVIDE A SCHEDULE ON THE PLAN SHOWING THE REQUIRED AND | | PROVIDED NUMBER OF FIXTURES PER TABLE 403.3 FBC P. | | PLEASE NOTE THAT DRINKING FOUNTAINS AND SERVICE SINKS | | ARE REQUIRED FOR F AND A OCCUPANCIES. AN EMERGENCY | | SHOWER AND EYE WASH STATION MAY BE REQUIRED FOR THE F | | OCCUPANCY DEPENDING UPON DEPARTMENT OF HEALTH, | | DEPARTMENT OF AGRICULTURE, OSHA, OR OTHER GOVERNING | | AGENCY REQUIREMENTS. PLEASE CONTACT THOSE AGENCIES FOR | | FURTHER INFORMATION. NOT PROVIDED. PLEASE NOTE THAT THE | | BUILDING PLANS EXAMINER HAS DETERMINED THE BREWERY IS A | | MIXED OCCUPANCY. REFER TO SECTION 403.1.1 FBC P- | | FRACTIONAL NUMBERS RESULTING FROM APPLYING THE FIXTURE | | RATIOS OF TABLE 403.1 SHALL BE ROUNDED UP TO THE NEXT | | WHOLE NUMBER. FOR CALCULATIONS INVOLVING MULTIPLE | | OCCUPANCIES, SUCH FRACTIONAL NUMBERS FOR EACH OCCUPANCY | | SHALL FIRST BE SUMMED AND THEN ROUNDED UP TO THE NEXT | | WHOLE NUMBER. | | | | 3) FAILED. A.100: THE PLAN INDICATES ACCESS TO ONE OF | | THE TWO TOILET ROOMS IS THROUGH A STORAGE AND BREWERY | | AREA WHICH IS NOT ALLOWED PER SECTION 403.3.1 FBC P. NO | | CHANGES MADE TO THE PLAN. | | | | 4) FAILED. A.100: THE PLAN SHOWS NEW SINKS IN WHAT | | APPEARS TO BE A BAR AREA, HOWEVER PLUMBING PLANS WERE | | NOT PROVIDED FOR THE PROPOSED PROJECT. PLEASE SUBMIT | | PLUMBING PLANS SHOWING THE LOCATIONS OF ALL NEW OR | | RELOCATED FIXTURES, FLOOR DRAINS, TRENCH DRAINS, | | INDIRECT WASTE RECEPTORS, ETC. PROVIDE SANITARY AND | | WATER RISER ISOMETRIC DRAWINGS, AND FLAT LINE PIPING | | PLANS SHOWING THE POINTS OF CONNECTIONS TO THE EXISTING | | DWV AND WATER DISTRIBUTION SYSTEMS- SECTIONS 107.2.1 | | AND 107.3.5.1.1 WPB. THE WATER RISER SHALL PROVIDE | | SYMBOLS TO INDICATE THE LOCATIONS OF REQUIRED BACKFLOW | | PREVENTERS, WATER HAMMER ARRESTORS, TRAP PRIMERS, SHUT | | OFF VALVES, AND ALL PIPING CONNECTIONS TO PROCESS OR | | BREWERY EQUIPMENT AND TANKS (IF APPLICABLE). NOT | | PROVIDED. IN ACCORDANCE WITH SECTION 107.3.5.1.3 WPB | | PLEASE PROVIDE PLUMBING PLANS INCLUDING ITEMS LISTED | | ABOVE AND: | | A) SANITARY DRAINAGE AND WATER PIPING LAYOUT PLANS AND | | ISOMETRIC DRAWINGS. | | B) A HOT WATER PLAN- LOCATIONS AND EQUIPMENT SCHEDULES | | FOR NEW WATER HEATERS- SECTION 502.1 FBC P & TABLE | | C404.1 FBC EC; THE MEANS OF PROVIDING TEMPERED WATER TO | | THE PUBLIC LAVATORES- SECTIONS 416.5 & 607.1.2 FBC P; | | HOT WATER PIPE INSULATION TABLE C403.2.10 FBC EC; | | LENGTH OF PIPING FROM THE HOT WATER SOURCE TO THE | | PUBLIC LAVATORIES- TABLE C404.5.1 FBC EC . PLEASE THE | | MAXIMUM DISTANCE IS 2 FT FOR ?-INCH PIPE. | | | | 5) FAILED. PROVIDE PLUMBING FIXTURE AND DEVICE | | SCHEDULES INDICATING MAKES AND MODELS AND LISTING AND | | LABELING INFORMATION- SECTION 303 FBC P. A SCHEDULE HAS | | BEEN PROVIDED ON A SEPARATE DOCUMENT FROM THE PLANS, | | HOWEVER A CORRELATING PLUMBING LAYOUT PLAN (SEE COMMENT | | 4) SHALL BE SUBMITTED IDENTIFYING THE LOCATIONS OF THE | | FIXTURES- SECTION 107.2.1 WPB. | | | | 6) FAILED. REFER TO SECTION 1003.3.1 FBC P: A GREASE | | INTERCEPTOR WILL BE REQUIRED TO RECEIVE THE DRAINAGE | | FROM FIXTURES AND EQUIPMENT WITH GREASE-LADEN WASTE | | LOCATED IN THE BREWERY AND PROCESSING AREAS. SHOW ON | | THE PLANS THE DRAINAGE SYSTEM FOR THE TANKS AND KETTLES | | AND OTHER PROCESS EQUIPMENT. THE CITY OF WEST PALM | | BEACH HAS NOT REQUIRED GREASE INTERCEPTORS FOR | | BREWERIES UNLESS COOKING OPERATIONS ARE CONDUCTED AS | | PART OF THE BUSINESS. GREASE INTERECEPTORS ARE ALSO | | REQUIRED FOR OIL OR FAT LADEN DRAINAGE FROM FIXTURES. | | PLEASE SUBMIT A BREWERY MENU AS EVIDENCE TO VERIFY THE | | GREASE INBTERCEPTOR WILL NOT BE REQUIRED. | | | | 7) FAILED. SHEET 8: REFER TO TABLE 608.1 AND SUBMIT | | SPECS FOR THE WATER SUPPLY HOSE BIB AND BACKFLOW | | PREVENTER, AND THE FDA HOSE AND CARBON FILTER- SECTION | | 107.2.1 WPB. THE NARRATIVE STATES THE FILTER IS REMOVED | | HOWEVER IT IS STILL SHOWING ON SHEET A100. | | | | 8) FAILED. SHEET 6: SHOW THE WATER FEED CONNECTION TO | | THE COLD WATER TANK. CLARIFY IF THE TANK WILL BE | | MANUALLY FILLED USING THE HOSE OR IF IT WILL BE | | HARD-PIPED- SEE SECTION 608.1 FBC P. A NEW FEED DIAGRAM | | HAS BEEN PROVIDED FOR THE TANKS BUT THE DIAGRAM DOES | | NOT SHOW THE LOCATION OF THE HOSE BIB AND POTABLE WATER | | SUPPLY LINE CONNECTION AS NO PLUMBING PLANS HAVE BEEN | | PROVIDED. | | | | 9) FAILED. ACCESSIBILITY: PLEASE BE ADVISED THAT ALL | | NEW PLUMBING FIXTURES FOR PUBLIC USE SHALL BE | | ACCESSIBLE- SECTION 201.1 FBC ACC. THE SUBMITTED PLANS | | ARE NOT SHOWING ANY NEW PUBLIC USE FIXTURES, HOWEVER | | ALL REVISED PLANS INDICATING NEW FIXTURE INSTALLATIONS, | | INCLUDING THE REQUIRED DRINKING FOUNTAINS, SHALL | | INCLUDE INSTALLATION DRAWINGS AND DETAILS IN COMPLIANCE | | WITH SECTION 601.1 FBC ACC. THE LOCATION OF THE | | REQUIRED DRINKING FOUNTAINS IS NOT SHOWN AND THE | | REQUESTED ACCESSIBILITY COMPLAINCE DRAWINGS HAVE NOT | | BEEN PROVIDED. PLEASE REVIEW THE LIST OF COMPLIANCE | | BELOW PER THE FBC ACC: | | A) CLEAR FLOOR SPACE DIAGRAMS AND DIMENSIONS FOR THE | | WATER CLOSETS- SECTION 604.3. | | B) CLEAR FLOOR SPACE DIAGRAMS AND DIMENSIONS FOR THE | | LAVATORIES- SECTION 606.2. | | C) TURNING SPACE DIAMETERS- SECTION 304.3. | | D) CENTERLINES OF THE WATER CLOSETS FROM THE SIDE | | WALLS- SECTION 604.2. | | E) HEIGHTS OF THE WATER CLOSET SEATS FROM THE FINISHED | | FLOORS- SECTION 604.4. | | F) HEIGHTS OF THE LAVATORY SINK RIMS OR COUNTER | | SURFACES FROM THE FINISHED FLOOR- SECTION 606.3. | | G) HEIGHTS OF THE MIRRORS FROM THE FINISHED FLOORS TO | | THE REFLECTIVE SURFACES- SECTION 603.3 | | H) LOCATIONS, LENGTHS, AND MOUNTING HEIGHTS OF GRAB | | BARS FOR THE WATER CLOSETS- SECTION 604.5 & 609.4, | | FIGURES 604. | | I) LOCATIONS OF THE WATER CLOSET FLUSH CONTROLS - | | SECTION 604.6. | | J) CENTERLINES OF THE TOILET PAPER DISPENSERS MEASURED | | FROM THE FRONTS OF THE WATER CLOSETS- SECTION AND | | FIGURE 604.7. | | K) KNEE AND TOE CLEARANCES FOR THE LAVATORIES- SECTION | | 606.2 | | L) REFER TO SECTIONS 306, 307, AND 602 FBC ACC AND | | PROVIDE DRINKING FOUNTAIN INSTALLATION DETAILS AND | | ELEVATION VIEWS SHOWING KNEE AND TOE CLEARANCES, SPOUT | | HEIGHTS, AND SPOUT LOCATIONS. SHOW THE REQUIRED 30 X 48 | | IN. CLEAR FLOOR SPACE FOR A FORWARD WHEELCHAIR APPROACH | | TO THE FOUNTAIN- SECTION 602.2 FBC ACC, AND SHOW HOW | | THE LOCATIONS OF THE FOUNTAINS WILL BE IN COMPLIANCE | | WITH SECTION 307.2 PROTRUSION LIMITS. | | | | NEW COMMENT | | 1) SHEETS 1, 2, 5, & 8 OF 8 SHEETS FROM INNOVATIVE | | ENGINEERING HAVE BEEN SUBMITTED., HOWEVER I DO NOT SEE | | THAT SHEETS 3, 4, 6, & 7 HAVE BEEN SUBMITTED. PLEASE | | PROVIDE THE SHEETS- SECTION 107.2.1 WPB. EQUIPMENT | | SPECS MISSING INCLUDE THE SPECS FOR THE BOIL KETTLE AND | | THE CHILLER- SECTION 107.2.1 WPB. | | 2) IT APPEARS THAT ALL THE TANK SUBMITTALS DO NOT | | PROVIDE LISTING OR LABELING INFORMATION. HAVE THE TANKS | | BEEN TESTED IN ACCORDANCE WITH ANY ACCEPTED STANDARDS | | SUCH AS NSF OR IAMPO?- SECTION 102.4 AND 107.2.1 WPB. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | CHRISTOPHER L. COLE | | MECHANICAL/PLUMBING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2020-07-07 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2020-07-07 |
Time |
14:41 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2020-07-07 |
Time |
12:03 |
Sent To |
|
|
Notes |
2020-07-07 14:44:30 | 1ST REVIEW FBC-2017 PLUMBING | | PERMIT- 20060761 | | 7/7/2020 | | | | CODES IN EFFECT: | | FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017 | | FBC ACC- FLORIDA ACCESSIBILITY CODE SIXTH ADDITION 2017 | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | 2017 | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | 2017 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2017 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) PROVIDE PLUMBING FIXTURE CALCULATIONS. PROVIDE A | | SCHEDULE ON THE PLAN SHOWING THE REQUIRED AND PROVIDED | | NUMBER OF FIXTURES PER TABLE 403.3 FBC P. PLEASE NOTE | | THAT DRINKING FOUNTAINS AND SERVICE SINKS ARE REQUIRED | | FOR F AND A OCCUPANCIES. AN EMERGENCY SHOWER AND EYE | | WASH STATION MAY BE REQUIRED FOR THE F OCCUPANCY | | DEPENDING UPON DEPARTMENT OF HEALTH, DEPARTMENT OF | | AGRICULTURE, OSHA, OR OTHER GOVERNING AGENCY | | REQUIREMENTS. PLEASE CONTACT THOSE AGENCIES FOR FURTHER | | INFORMATION. | | | | 2) SHEET A.100: PLEASE LABEL THE TOILET ROOMS AS EITHER | | MALE OR FEMALE- SEE SECTIONS 403.2 AND 403.2.1 FBC P. | | THE PLAN INDICATES THE TOILET ROOMS ARE EXISTING. | | PLEASE PROVIDE ENLARGED DRAWINGS AND DETAILS TO VERIFY | | COMPLIANCE WITH SECTION 1006.1 FBC EX, AND SECTION | | 601.1 FBC ACC. | | | | 3) A.100: THE PLAN INDICATES ACCESS TO ONE OF THE TWO | | TOILET ROOMS IS THROUGH A STORAGE AND BREWERY AREA | | WHICH IS NOT ALLOWED PER SECTION 403.3.1 FBC P. | | | | 4) A.100: THE PLAN SHOWS NEW SINKS IN WHAT APPEARS TO | | BE A BAR AREA, HOWEVER PLUMBING PLANS WERE NOT PROVIDED | | FOR THE PROPOSED PROJECT. PLEASE SUBMIT PLUMBING PLANS | | SHOWING THE LOCATIONS OF ALL NEW OR RELOCATED FIXTURES, | | FLOOR DRAINS, TRENCH DRAINS, INDIRECT WASTE RECEPTORS, | | ETC. PROVIDE SANITARY AND WATER RISER ISOMETRIC | | DRAWINGS, AND FLAT LINE PIPING PLANS SHOWING THE POINTS | | OF CONNECTIONS TO THE EXISTING DWV AND WATER | | DISTRIBUTION SYSTEMS- SECTIONS 107.2.1 AND 107.3.5.1.1 | | WPB. THE WATER RISER SHALL PROVIDE SYMBOLS TO INDICATE | | THE LOCATIONS OF REQUIRED BACKFLOW PREVENTERS, WATER | | HAMMER ARRESTORS, TRAP PRIMERS, SHUT OFF VALVES, AND | | ALL PIPING CONNECTIONS TO PROCESS OR BREWERY EQUIPMENT | | AND TANKS (IF APPLICABLE). | | | | 5) PROVIDE PLUMBING FIXTURE AND DEVICE SCHEDULES | | INDICATING MAKES AND MODELS AND LISTING AND LABELING | | INFORMATION- SECTION 303 FBC P. | | | | 6) REFER TO SECTION 1003.3.1 FBC P: A GREASE | | INTERCEPTOR WILL BE REQUIRED TO RECEIVE THE DRAINAGE | | FROM FIXTURES AND EQUIPMENT WITH GREASE-LADEN WASTE | | LOCATED IN THE BREWERY AND PROCESSING AREAS. SHOW ON | | THE PLANS THE DRAINAGE SYSTEM FOR THE TANKS AND KETTLES | | AND OTHER PROCESS EQUIPMENT. | | | | 7) SHEET 8: REFER TO TABLE 608.1 AND SUBMIT SPECS FOR | | THE WATER SUPPLY HOSE BIB AND BACKFLOW PREVENTER, AND | | THE FDA HOSE AND CARBON FILTER- SECTION 107.2.1 WPB. | | | | 8) SHEET 6: SHOW THE WATER FEED CONNECTION TO THE COLD | | WATER TANK. CLARIFY IF THE TANK WILL BE MANUALLY FILLED | | USING THE HOSE OR IF IT WILL BE HARD-PIPED- SEE SECTION | | 608.1 FBC P. | | | | 9) ACCESSIBILITY: PLEASE BE ADVISED THAT ALL NEW | | PLUMBING FIXTURES FOR PUBLIC USE SHALL BE ACCESSIBLE- | | SECTION 201.1 FBC ACC. THE SUBMITTED PLANS ARE NOT | | SHOWING ANY NEW PUBLIC USE FIXTURES, HOWEVER ALL | | REVISED PLANS INDICATING NEW FIXTURE INSTALLATIONS, | | INCLUDING THE REQUIRED DRINKING FOUNTAINS, SHALL | | INCLUDE INSTALLATION DRAWINGS AND DETAILS IN COMPLIANCE | | WITH SECTION 601.1 FBC ACC. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | CHRISTOPHER L. COLE | | MECHANICAL/PLUMBING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
F |
Date |
2021-08-17 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2021-08-17 |
Time |
16:02 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2021-08-17 |
Time |
16:02 |
Sent To |
|
|
Notes |
2021-08-17 16:02:19 | DESIGNER MUST DIGITALLY SIGN AND SEAL ALL PAGES OF HIS | | DESIGN. FS471.025 | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2020-07-10 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2020-07-10 |
Time |
10:13 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2020-07-10 |
Time |
09:45 |
Sent To |
|
|
Notes |
2020-07-10 10:15:16 | DESIGNER MUST DIGITALLY SIGN AND SEAL ALL PAGES OF HIS | | DESIGN. FS471.025 | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2021-08-13 |
|
|
Cont ID |
|
Sent By |
awooten |
Date |
2021-08-13 |
Time |
|
Rev Time |
0.00 |
Received By |
awooten |
Date |
2021-08-13 |
Time |
|
Sent To |
|
|
Notes |
2021-08-13 14:21:04 | *********ZONING REVIEW FAILED********* | | | | ****DUE TO THIS LOCATION BEING ZONED INDUSTRIAL, IT IS | | EXEMPT FROM ADDITIONAL STANDARDS 1 AND 2 LOCATED IN | | SECTION 6.1. PLEASE SHOW THAT YOU MEET THE OTHER | | REQUIREMENTS ON FLOOR PLAN. | | | | 6.1. BREWPUB/MICROBREWERY/MICRO-DISTILLERY/MICRO-WINERY | | (PXR: SEE ITEM 12.1, TABLE IX-I). | | | | A. ADDITIONAL APPLICATION REQUIREMENTS | | | | 1. A WRITTEN STATEMENT THAT THE PROPOSED FACILITY WILL | | COMPLY WITH ALL APPLICABLE STATE LAWS AND REGULATIONS. | | (SUBMITTED) | | 2. THE ADDITIONAL STANDARDS FOR THIS USE SHALL NOT | | APPLY TO BONA FIDE RESTAURANTS DERIVING MORE THAN 51 | | PERCENT OF SALES FROM FOOD AND SERVING MANUFACTURES | | ALCOHOLIC BEVERAGES FOR ON-SITE CONSUMPTION ONLY AND | | WITH NO DISTRIBUTION. (NOT A RESTAURANT, N/A.) | | 3. A FLOOR PLAN DEPICTING COMPLIANCE WITH ADDITIONAL | | STANDARD 2 SHALL BE SUBMITTED AS PART OF THE | | CERTIFICATE OF USE APPLICATION. NOT A RESTAURANT, N/A.) | | | | B. ADDITIONAL STANDARDS . | | | | 1. THE MAXIMUM SIZE OF A BUILDING CONTAINING A BREWPUB, | | MICROBREWERY, MICRO-DISTILLERY, OR MICRO-WINERY USE | | SHALL NOT EXCEED 3,000 SQUARE FEET IN THE NORTHWOOD | | MIXED-USE DISTRICT (NMUD) OR 5,000 SQUARE FEET IN THE | | GENERAL COMMERCIAL (GC) ZONING DISTRICT. THERE SHALL BE | | NO LIMIT FOR A FACILITY LOCATED WITHIN THE INDUSTRIAL | | (IND) ZONING DISTRICT. (ZONED INDUSTRIAL, N/A.) | | | | 2. THIS USE SHALL BE PERMITTED ONLY IN CONJUNCTION WITH | | A RESTAURANT, BAR, TASTING ROOM OR RETAIL SERVICE. A | | MAXIMUM OF 75 PERCENT OF THE SQUARE FOOTAGE OF THE | | FACILITY (INCLUSIVE OF OUTDOOR SEATING FACILITIES) | | SHALL BE DEDICATED TO THE BREWERY FUNCTION INCLUDING, | | BUT NOT LIMITED TO, BREW HOUSE, BOILING AND WATER | | TREATMENT AREAS, BOTTLING AND KEGGING LINES, MALT | | MILLING AND STORAGE, FERMENTATION TANKS, CONDITION | | TANKS AND SERVING TANKS. THIS STANDARD SHALL NOT APPLY | | TO PROPERTIES LOCATED WITHIN THE INDUSTRIAL (I) ZONING | | DISTRICT). N/A | | | | 3. EXCEPT FOR LOADING AND UNLOADING, ALL ACTIVITIES | | SHALL OCCUR WITHIN A BUILDING. DELIVERY ACCESS AND | | LOADING BAYS SHALL NOT FACE TOWARD ANY STREET, | | EXCLUDING ALLEYS. DELIVERY ACCESS AND LOADING BAYS | | FACING AN ADJACENT RESIDENTIAL USE, OR RESIDENTIAL | | ZONING DISTRICT, SHALL HAVE THE DOORS CLOSED AT ALL | | TIMES, EXCEPT DURING THE MOVEMENT OF RAW MATERIALS, | | OTHER SUPPLIES AND FINISHED PRODUCTS INTO AND OUT OF | | THE BUILDING. ( PROPERTY HAS A SERVICE ALLEY IN THE | | REAR WHERE THEY WILL DO LOADING AND UNLOADING. LOADING | | BAYS DO NOT FACE AN ADJACENT RESIDENTIAL DISTRICT/USE.) | | | | 4. ALL NEW FACILITIES, WHETHER IN AN EXISTING BUILDING | | OR NEW BUILDING SHALL PROVIDE ON-SITE LOADING IN | | ACCORDANCE WITH ZLDR SECTION 94-485(P), TABLE XV-4. FOR | | NEW FACILITIES LOCATING WITHIN AN EXISTING BUILDING, | | WITH NO CHANGE IN BUILDING FOOTPRINT, IF A FUNCTIONAL | | ALLEY EXISTS ADJACENT TO THE FACILITY, FACILITIES MAY | | USE THE ALLEY TO ACCOUNT FOR ONE OF THE REQUIRED | | ON-SITE LOADING SPACES. ( PROPERTY HAS AN SERVICE ALLEY | | IN THE REAR.) | | | | 5. ALL MECHANICAL EQUIPMENT VISIBLE FROM THE STREET | | (EXCLUDING ALLEYS), WITH AN ADJACENT RESIDENTIAL USE OR | | WITHIN A RESIDENTIAL ZONING DISTRICT, SHALL BE SCREENED | | USING ARCHITECTURAL FEATURES CONSISTENT WITH THE | | PRINCIPAL STRUCTURE. (THE PROPERTY IS NOT WITHIN A | | RESIDENTIAL ZONING DISTRICT/USE.) | | | | 6. NO OUTDOOR STORAGE SHALL BE ALLOWED. THIS | | PROHIBITION INCLUDES USE OF PORTABLE STORAGE UNITS, | | CARGO CONTAINERS, AND TRACTOR TRAILERS. (NO OUTDOOR | | STORAGE IS BEING PROPOSED.) | | | | 7. OUTDOOR SEATING AREAS OR AREAS OF PATRON | | CONGREGATION SHALL BE PROHIBITED WHEN THE PROPERTY | | DIRECTLY ABUTS A RESIDENTIAL ZONING DISTRICT. (SUBJECT | | PROPERTY DOES NOT ABUT A RESIDENTIAL ZONING DISTRICT | | AND OUTDOOR SEATING IS NOT PROPOSEDL) | | | | 8. DRIVE-THROUGH FACILITIES ARE PROHIBITED. (THE | | BREWERY IS NOT PROPOSING A DRIVE-THROUGH.) | | | | ****PLEASE SHOW THAT YOU HAVE MET CRITERIA A ON YOUR | | SITE PLAN AS WELL AS PROVIDE PROOF OF LICENSE INDICATED | | IN B FROM CHAPTER 6 - ALCOHOLIC BEVERAGES. | | | | CHAPTER 6 ALCOHOLIC BEVERAGES | | | | (E) OTHER EXCEPTIONS. THE PROVISIONS OF SUBSECTIONS (B) | | OF THIS SECTION SHALL NOT APPLY TO: | | | | (1) BREWPUB/MICROBREWERY/MICRO-DISTILLERY/MICRO-WINERY | | AS DEFINED IN THIS CHAPTER, WHERE THE SALE OF ALCOHOLIC | | BEVERAGES FOR ON-SITE CONSUMPTION IS INCIDENTAL TO THE | | PRODUCTION, DISTRIBUTION, AND SALE OF PACKAGED | | ALCOHOLIC BEVERAGES FOR OFF-SITE CONSUMPTION AND MEETS | | THE FOLLOWING CRITERIA: | | | | A. AT LEAST 65 PERCENT OF THE SQUARE FOOTAGE OF THE | | FACILITY (INCLUSIVE OF OUTDOOR SEATING FACILITIES) | | SHALL BE DEDICATED TO THE BREWERY FUNCTION INCLUDING, | | BUT NOT LIMITED TO, BREW HOUSE, BOILING AND WATER | | TREATMENT AREAS, BOTTLING AND KEGGING LINES, MALT | | MILLING AND STORAGE, FERMENTATION TANKS, CONDITION | | TANKS AND SERVING TANKS. | | | | **PLEASE INDICATE SQUARE FOOTAGE CALCULATIONS ON FLOOR | | PLAN SHOWING THAT THE 65% REQUIREMENT HAS BEEN MET.** | | | | B. BUSINESS MUST HOLD ONE OF THE FOLLOWING LICENSES | | ISSUED BY THE FLORIDA DEPARTMENT OF BUSINESS AND | | PROFESSIONAL REGULATIONS, DIVISION OF ALCOHOLIC | | BEVERAGES AND TOBACCO: CMB, AMW, BMWC, DD. | | | | **PLEASE SUBMIT A COPY OF CMB LICENSE.** | | | | | | ALANA WOOTEN | | PLANNER | | PLANNING DIVISION | | 561-822-1449 | | [email protected] | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2020-07-09 |
|
|
Cont ID |
|
Sent By |
awooten |
Date |
2020-07-09 |
Time |
|
Rev Time |
|
Received By |
awooten |
Date |
2020-07-09 |
Time |
|
Sent To |
|
|
Notes |
2020-07-09 10:43:51 | *********ZONING REVIEW FAILED********* | | | | ****DUE TO THIS LOCATION BEING ZONED INDUSTRIAL, IT IS | | EXEMPT FROM ADDITIONAL STANDARDS 1 AND 2 LOCATED IN | | SECTION 6.1. PLEASE SHOW THAT YOU MEET THE OTHER | | ADDITIONAL STANDARDS 3-8 ON YOUR FLOOR PLAN AND SITE | | PLAN. | | | | 6.1. BREWPUB/MICROBREWERY/MICRO-DISTILLERY/MICRO-WINERY | | (PXR: SEE ITEM 12.1, TABLE IX-I). | | | | A. ADDITIONAL APPLICATION REQUIREMENTS . | | | | 1. A WRITTEN STATEMENT THAT THE PROPOSED FACILITY WILL | | COMPLY WITH ALL APPLICABLE STATE LAWS AND REGULATIONS. | | 2. THE ADDITIONAL STANDARDS FOR THIS USE SHALL NOT | | APPLY TO BONA FIDE RESTAURANTS DERIVING MORE THAN 51 | | PERCENT OF SALES FROM FOOD AND SERVING MANUFACTURES | | ALCOHOLIC BEVERAGES FOR ON-SITE CONSUMPTION ONLY AND | | WITH NO DISTRIBUTION. | | 3. A FLOOR PLAN DEPICTING COMPLIANCE WITH ADDITIONAL | | STANDARD 2 SHALL BE SUBMITTED AS PART OF THE | | CERTIFICATE OF USE APPLICATION. | | | | B. ADDITIONAL STANDARDS . | | | | 1. THE MAXIMUM SIZE OF A BUILDING CONTAINING A BREWPUB, | | MICROBREWERY, MICRO-DISTILLERY, OR MICRO-WINERY USE | | SHALL NOT EXCEED 3,000 SQUARE FEET IN THE NORTHWOOD | | MIXED-USE DISTRICT (NMUD) OR 5,000 SQUARE FEET IN THE | | GENERAL COMMERCIAL (GC) ZONING DISTRICT. THERE SHALL BE | | NO LIMIT FOR A FACILITY LOCATED WITHIN THE INDUSTRIAL | | (IND) ZONING DISTRICT. N/A | | | | 2. THIS USE SHALL BE PERMITTED ONLY IN CONJUNCTION WITH | | A RESTAURANT, BAR, TASTING ROOM OR RETAIL SERVICE. A | | MAXIMUM OF 75 PERCENT OF THE SQUARE FOOTAGE OF THE | | FACILITY (INCLUSIVE OF OUTDOOR SEATING FACILITIES) | | SHALL BE DEDICATED TO THE BREWERY FUNCTION INCLUDING, | | BUT NOT LIMITED TO, BREW HOUSE, BOILING AND WATER | | TREATMENT AREAS, BOTTLING AND KEGGING LINES, MALT | | MILLING AND STORAGE, FERMENTATION TANKS, CONDITION | | TANKS AND SERVING TANKS. THIS STANDARD SHALL NOT APPLY | | TO PROPERTIES LOCATED WITHIN THE INDUSTRIAL (I) ZONING | | DISTRICT). N/A | | | | 3. EXCEPT FOR LOADING AND UNLOADING, ALL ACTIVITIES | | SHALL OCCUR WITHIN A BUILDING. DELIVERY ACCESS AND | | LOADING BAYS SHALL NOT FACE TOWARD ANY STREET, | | EXCLUDING ALLEYS. DELIVERY ACCESS AND LOADING BAYS | | FACING AN ADJACENT RESIDENTIAL USE, OR RESIDENTIAL | | ZONING DISTRICT, SHALL HAVE THE DOORS CLOSED AT ALL | | TIMES, EXCEPT DURING THE MOVEMENT OF RAW MATERIALS, | | OTHER SUPPLIES AND FINISHED PRODUCTS INTO AND OUT OF | | THE BUILDING. | | | | 4. ALL NEW FACILITIES, WHETHER IN AN EXISTING BUILDING | | OR NEW BUILDING SHALL PROVIDE ON-SITE LOADING IN | | ACCORDANCE WITH ZLDR SECTION 94-485(P), TABLE XV-4. FOR | | NEW FACILITIES LOCATING WITHIN AN EXISTING BUILDING, | | WITH NO CHANGE IN BUILDING FOOTPRINT, IF A FUNCTIONAL | | ALLEY EXISTS ADJACENT TO THE FACILITY, FACILITIES MAY | | USE THE ALLEY TO ACCOUNT FOR ONE OF THE REQUIRED | | ON-SITE LOADING SPACES. | | | | 5. ALL MECHANICAL EQUIPMENT VISIBLE FROM THE STREET | | (EXCLUDING ALLEYS), WITH AN ADJACENT RESIDENTIAL USE OR | | WITHIN A RESIDENTIAL ZONING DISTRICT, SHALL BE SCREENED | | USING ARCHITECTURAL FEATURES CONSISTENT WITH THE | | PRINCIPAL STRUCTURE. | | | | 6. NO OUTDOOR STORAGE SHALL BE ALLOWED. THIS | | PROHIBITION INCLUDES USE OF PORTABLE STORAGE UNITS, | | CARGO CONTAINERS, AND TRACTOR TRAILERS. | | | | 7. OUTDOOR SEATING AREAS OR AREAS OF PATRON | | CONGREGATION SHALL BE PROHIBITED WHEN THE PROPERTY | | DIRECTLY ABUTS A RESIDENTIAL ZONING DISTRICT. | | | | 8. DRIVE-THROUGH FACILITIES ARE PROHIBITED. | | | | ****PLEASE SHOW THAT YOU HAVE MET CRITERIA A ON YOUR | | SITE PLAN AS WELL AS PROVIDE PROOF OF LICENSE INDICATED | | IN B FROM CHAPTER 6 - ALCOHOLIC BEVERAGES. | | | | CHAPTER 6 ALCOHOLIC BEVERAGES | | | | (E) OTHER EXCEPTIONS. THE PROVISIONS OF SUBSECTIONS (B) | | OF THIS SECTION SHALL NOT APPLY TO: | | | | (1) BREWPUB/MICROBREWERY/MICRO-DISTILLERY/MICRO-WINERY | | AS DEFINED IN THIS CHAPTER, WHERE THE SALE OF ALCOHOLIC | | BEVERAGES FOR ON-SITE CONSUMPTION IS INCIDENTAL TO THE | | PRODUCTION, DISTRIBUTION, AND SALE OF PACKAGED | | ALCOHOLIC BEVERAGES FOR OFF-SITE CONSUMPTION AND MEETS | | THE FOLLOWING CRITERIA: | | | | A. AT LEAST 65 PERCENT OF THE SQUARE FOOTAGE OF THE | | FACILITY (INCLUSIVE OF OUTDOOR SEATING FACILITIES) | | SHALL BE DEDICATED TO THE BREWERY FUNCTION INCLUDING, | | BUT NOT LIMITED TO, BREW HOUSE, BOILING AND WATER | | TREATMENT AREAS, BOTTLING AND KEGGING LINES, MALT | | MILLING AND STORAGE, FERMENTATION TANKS, CONDITION | | TANKS AND SERVING TANKS. | | | | B. BUSINESS MUST HOLD ONE OF THE FOLLOWING LICENSES | | ISSUED BY THE FLORIDA DEPARTMENT OF BUSINESS AND | | PROFESSIONAL REGULATIONS, DIVISION OF ALCOHOLIC | | BEVERAGES AND TOBACCO: CMB, AMW, BMWC, DD. | | | | | | ALANA WOOTEN | | PLANNER | | PLANNING DIVISION | | 561-822-1449 | | [email protected] | | |
|
|
|