|
 |
 |
 |
 |
 |
Plan Review Details - Permit 20060658
Plan Review Stops For Permit 20060658 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2020-07-21 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2020-07-21 |
Time |
10:45 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2020-07-21 |
Time |
10:45 |
Sent To |
|
|
Notes |
2020-07-21 10:45:23 | JONATHAN BROOKS JR. | | BUILDING PLANS EXAMINER | | WORK HOURS TUESDAY & THURSDAY 7:00 AM TO 3:00 PM | | (561) 805-6716 ALTERNATE: CONTACT SAMANTHA HILL (561) | | 805-6724 | | [email protected] | | | | 1ST REVIEW: FBC 2017 6TH EDITION | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | FBC B = FBC BUILDING | | FBC R = FBC RESIDENTIAL | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | IF THE RESUBMITTAL IS NOT PREPARED BY A DESIGN | | PROFESSIONAL (ARCHITECT OR ENGINEER), AND THE PAGES ARE | | 11X17 OR SMALLER, YOU MAY RESUBMIT ALONG WITH A | | COMPLETED RESUBMITTAL FORM, VIA EMAIL TO | | [email protected]. THE EMAIL SHOULD INCLUDE THE PERMIT | | NUMBER AND "RESUBMITTAL" IN THE SUBJECT LINE. THE | | RESUBMITTAL FORM CAN BE FOUND AT THIS WEBSITE: | | HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B | | UILDING-PERMIT-FORMS | | | | 1. FBC R 310.4. REVISE PLAN TO SHOW REQUIRED MEANS OF | | EGRESS. INCLUDE ROOM DESIGNATION. | | 2. SUBMITTED PRODUCT APPROVAL FL16893-R4 HAS BEEN | | REVISED TO FL16893-R5. PLEASE PROVIDE TWO SETS. ALL | | APPLICABLE DETAILS AND ATTACHMENTS MUST BE CLEARLY | | IDENTIFIED ON THE PRODUCT APPROVAL DRAWINGS. DETAILS | | AND ATTACHMENTS NOT SPECIFICALLY COVERED IN PRODUCT | | APPROVALS WILL NEED SITE-SPECIFIC ENGINEERING. AS PER | | RULE 61G20-3 | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2020-06-15 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2020-06-15 |
Time |
11:04 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2020-06-15 |
Time |
11:04 |
Sent To |
|
|
Notes |
2020-06-15 11:06:34 | PETER E VALENTI | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6673 | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | FBC M = FBC MECHANICAL | | | | BUILDING REVIEW DENIED: | | | | 1. FBC R 301, COMPLETE THE "SCHEDULE FOR INSTALLATION | | OF OPENING PROTECTIVE DEVICES" OR PROVIDE ALL | | INFORMATION REQUIRED IN ANOTHER FORMAT (SUCH AS EXCEL | | SPREADSHEET): | | | | HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B | | UILDING-PERMIT-FORMS?PAGE=2 | | | | 2. WHEN COMPLETING THE INSTALLATION SCHEDULE, PLEASE | | NOTE FACTORS APPLY DEPENDING ON SUBSTRATE, EDGE | | DISTANCE AND FASTENER. FOR FASTENER, IF USING TAPCON, | | BE SPECIFIC AS TO WHICH TAPCON. | | | | PLEASE CONTACT ME IF YOU NEED ASSISTANCE. | | | | 3. REVISE PLAN TO SHOW MEANS OF ESCAPE REQUIRED BY FBC | | R 310.4; INCLUDE ROOM DESIGNATION. | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2020-07-21 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2020-07-21 |
Time |
10:45 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2020-07-21 |
Time |
|
Sent To |
|
|
Notes |
2020-07-18 09:31:16 | ROUTED TO BLDG. MISC 1 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2020-06-15 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2020-06-15 |
Time |
11:06 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2020-06-11 |
Time |
15:00 |
Sent To |
|
|
Notes |
2020-06-11 15:01:11 | ROUTED TO BLDG <$5K |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |