Plan Review Stops For Permit 20060558 |
Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
Rev No |
2 |
Status |
P |
Date |
2020-07-13 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-07-13 |
Time |
12:08 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-07-13 |
Time |
12:07 |
Sent To |
|
|
Notes |
|
|
Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
Rev No |
1 |
Status |
F |
Date |
2020-06-15 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2020-06-15 |
Time |
10:16 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2020-06-15 |
Time |
10:15 |
Sent To |
|
|
Notes |
2020-06-15 10:16:48 | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | CONTRACTOR, ON LETTERHEAD, STATING THAT THE | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | COUNTY WILL BE FOLLOWED AND THAT NOTIFICATION WILL BE | | GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS | | REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE: | | | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | RENOVATION.HTML | | 19120504 | | THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO | | [email protected]. THE INFORMATION SHOULD BE IN PDF | | FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE INCLUDE | | THE PERMIT NUMBER AND ?ASBESTOS? IN THE SUBJECT LINE. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2020-08-12 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2020-08-12 |
Time |
17:00 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2020-08-12 |
Time |
16:30 |
Sent To |
|
|
Notes |
2020-08-12 17:00:21 | 2017 FBC- BUILDING PLAN REVIEW | | W. P. B. PERMIT: 20060558 | | ADD: 20060558 | | CONT: RHODES REMODELING LLC | | TEL: 561-798-1382 | | E-MAIL: [email protected] | | | | 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION | | | | 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | BUILDING CODE, BUILDING. | | | | 3RD REVIEW | | DATE: WED. AUGUST 12TH/ 2020 | | ACTION: APPROVED. | | INTERTEK REPORT SEE PAGES | | 19/25 FOR IIC= 53 | | 17/25 FOR STC=17/25 | | | | ALL WORK PER CITY CODES IS | | SUBJECT TO THE FIELD | | INSPECTOR'S APPROVAL. | | | | JAMES A. WITMER BN, PX, SFP, CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | TEL: 561-805-6717 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2020-07-19 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2020-07-19 |
Time |
15:13 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2020-07-19 |
Time |
14:44 |
Sent To |
|
|
Notes |
2020-07-19 15:05:40 | 2017 FBC- BUILDING PLAN REVIEW | | W. P. B. PERMIT: 20060558 | | ADD: 20060558 | | CONT: RHODES REMODELING LLC | | TEL: 561-798-1382 | | E-MAIL: [email protected] | | | | 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION | | | | 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | BUILDING CODE, BUILDING. | | | | 2ND REVIEW | | DATE: SUN. JULY 19TH/ 2020 | | ACTION: DENIED | | | | 1) THE DOCUMENT SCOPE OF WORK LIST THE INSTALATION OF | | VINYL FLOORING AND PERGO UNDERLAYMENT. TO DATE WE HAVE | | NOT RECEIVED TESTING REPORTS FOR THE PRODUCT PERGO | | UNDERLAYMENT AND VINYL FLOORING. | | | | FLOOR INSULATION (FBC-B 2017) | | FOR TILE, STONE, MARBLE, VINYL AND WOOD FLOORING ALL | | NEED TO HAVE HAD THE SOUND UNDERLAYMENT TESTED FLOOR | | ASSEMBLIES TO THE FOLLOWING STANDARDS AND MEET THE | | QUALIFICATIONS LISTED UNDER EACH OF THE STANDARDS FOR A | | 6 INCH CONCRETE FLOOR ASSEMBLY/ NO DROPPED CEILING: | | PLEASE PROVIDE TEST REPORTS SHOWING COMPLIANCE WITH: | | | | TYPE I AND II BUILDINGS | | 1A) FBC-B 2017 1207.3 STRUCTURE-BORNE SOUND. | | FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR | | BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA | | WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION | | CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD | | TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492. | | | | 1B) FBC-B 2017 1207.2 AIR-BORNE SOUND. | | WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES | | SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM | | PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION | | CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) | | FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM | | E 90. | | | | 1C) FLAME SPREAD- FBC-B 2017 603.1. EXCEPTION 2. | | INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID | | DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED | | TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. | | | | FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS | | A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL | | MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A | | MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723. | | | | 2) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID | | 19 IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS | | 561-718-9724. | | JAMES A. WITMER BN, PX, SFP, CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | TEL: 561-805-6717 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2020-06-15 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2020-06-15 |
Time |
10:54 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2020-06-15 |
Time |
10:15 |
Sent To |
|
|
Notes |
2020-06-15 10:49:24 | 2017 FBC- BUILDING PLAN REVIEW | | W. P. B. PERMIT: 20060558 | | ADD: 20060558 | | CONT: RHODES REMODELING LLC | | TEL: 561-798-1382 | | E-MAIL: [email protected] | | | | 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION | | | | 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | BUILDING CODE, BUILDING. | | | | 1ST REVIEW | | DATE: MON. JUNE 15TH/ 2020 | | ACTION: DENIED | | | | 1) THE DOCUMENT SCOPE OF WORK LIST TO DIFFERENT | | FLOORING MATERIALS, 1ST VINYL PLANK FLOORING THROUGHOUT | | THE UNIT WITH THE EXCEPTION OF MARBLE/ TILE IN THE | | MASTER BATH FLOOR. THE FIRST ISSUE WITH THE VINYL PLANK | | FLOORING IS NO DOCUMENTATION WAS SUBMITTED FOR THIS | | PRODUCT NOR THE UNDERLAYMENT. NO TEST RESULTS WERE | | SUBMITTED, IS THE INSULATION PART OF THE VINYL PLANK? | | | | THE SECOND MATERIAL THAT CAN BE USED FOR UNDERLAYMENT | | FOR EITHER TILE OR MARBLE FLOORING IS THE WHISPER MAT | | CS. THE CITY IS IN RECEIPT OF THE ACTUAL TEST REPORTS | | FOR THIS PRODUCT FOR THE IIC RATING, STC RATING BOTH 50 | | OR BETTER AND THE ACTUAL FLAME SPREAD TEST, WE CAN HAVE | | THESE TEST UPLOADED IN TO FILE. | | | | FLOOR INSULATION (FBC-B 2017) | | FOR TILE, STONE, MARBLE, VINYL AND WOOD FLOORING ALL | | NEED TO HAVE HAD THE SOUND UNDERLAYMENT TESTED FLOOR | | ASSEMBLIES TO THE FOLLOWING STANDARDS AND MEET THE | | QUALIFICATIONS LISTED UNDER EACH OF THE STANDARDS FOR A | | 6 INCH CONCRETE FLOOR ASSEMBLY/ NO DROPPED CEILING: | | PLEASE PROVIDE TEST REPORTS SHOWING COMPLIANCE WITH: | | | | TYPE I AND II BUILDINGS | | 1A) FBC-B 2017 1207.3 STRUCTURE-BORNE SOUND. | | FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR | | BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA | | WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION | | CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD | | TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492. | | | | 1B) FBC-B 2017 1207.2 AIR-BORNE SOUND. | | WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES | | SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM | | PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION | | CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) | | FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM | | E 90. | | | | 1C) FLAME SPREAD- FBC-B 2017 603.1. EXCEPTION 2. | | INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID | | DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED | | TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. | | | | FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS | | A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL | | MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A | | MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723. | | | | 2) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID | | 19 IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS | | 561-718-9724. | | JAMES A. WITMER BN, PX, SFP, CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | TEL: 561-805-6717 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2020-07-30 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2020-07-30 |
Time |
17:26 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2020-07-30 |
Time |
17:19 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2020-06-29 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2020-06-29 |
Time |
15:07 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2020-06-29 |
Time |
15:04 |
Sent To |
|
|
Notes |
2020-06-29 15:17:23 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2014 5TH EDITION | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 | | 5TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION, | | PART VIII ELECTRICAL | | NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | FLORIDA BUILDING CODE 2017 6TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | NFPA 70 2014 EDITION | | | | JAKE LEAHY BN, BU, PX | | ELECTRICAL PLANS EXAMINER II | | 561-805-6713 | | [email protected] | | | | KITCHEN LAYOUT SHOWS PANEL NEXT TO THE REFRIGERATOR, IS | | PANEL FACING INTO THE KITCHEN? IF SO THIS IS A | | VIOLATION OF 110.26 | | | | E3405.1WORKING SPACE AND CLEARANCES. | | ACCESS AND WORKING SPACE SHALL BE PROVIDED AND | | MAINTAINED AROUND ALL ELECTRICAL EQUIPMENT TO PERMIT | | READY AND SAFE OPERATION AND MAINTENANCE OF SUCH | | EQUIPMENT IN ACCORDANCE WITH THIS SECTION AND FIGURE | | E3405.1. (110.26) 30" WIDE AND 36" DEEP | | | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2020-07-14 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2020-07-14 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2020-07-14 |
Time |
11:48 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2020-06-12 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2020-06-12 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2020-06-12 |
Time |
13:11 |
Sent To |
|
|
Notes |
2020-06-12 13:14:26 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | 1) PROPOSED MECHANICAL SHEET - THERE IS INDICATION OF | | THE DUCT WORK TIEING INTO THE HALLWAY DUCT WORK. | | | | THIS DUCT WORK APPEARS TO BE BREECHING A FIRE RATED | | CORRIDOR WALL AND THERE IS NO FIRE DAMPER INDICATED. | | | | PLEASE REVIEW AND CORRECT. | | | | | | | | 2) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | ABOVE. | | | | | | 3) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2020-08-12 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2020-08-12 |
Time |
17:00 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2020-08-07 |
Time |
09:55 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2020-07-30 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2020-07-30 |
Time |
17:26 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2020-07-13 |
Time |
11:21 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2020-07-06 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2020-07-06 |
Time |
11:21 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2020-06-11 |
Time |
09:40 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2020-07-23 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2020-07-23 |
Time |
10:52 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2020-07-23 |
Time |
10:52 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2020-07-06 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2020-07-06 |
Time |
10:28 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2020-07-06 |
Time |
10:28 |
Sent To |
|
|
Notes |
2020-07-06 10:28:41 | 1ST REVIEW FBC-2017 MECHANICAL | | PERMIT-20060558 | | | | CODES IN EFFECT: | | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | 2017 | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | 2017 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2017 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) PLEASE PROVIDE A COMPLETE DRAWING OF THE UNIT | | SHOWING ALL DUCT WORK BEING REPLACED OR MOVED; INCLUDE | | DUCT SIZES, SIZE OF SUPPLY VENTS. FBC FS 107.2.1 | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD | | SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER | | SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN | | THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS | | PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS | | PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR | | UPDATED. | | | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2020-07-23 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2020-07-23 |
Time |
09:56 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2020-07-23 |
Time |
08:12 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2020-07-02 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2020-07-02 |
Time |
09:45 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2020-07-02 |
Time |
09:40 |
Sent To |
|
|
Notes |
2020-07-02 09:58:09 | 1ST REVIEW FBC-2017 PLUMBING | | PERMIT-20060558 | | 7/2/2020 | | | | CODES IN EFFECT: | | | | FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017 | | FBC ACC- FLORIDA ACCESSIBILITY CODE SIXTH ADDITION 2017 | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | 2017 | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | 2017 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2017 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) PROVIDE A PLUMBING PLAN INCLUDING A SCOPE OF WORK | | OUTLINE AND LOCATIONS OF ALL FIXTURES TO BE REPLACED OR | | INSTALLED. INCLUDE A SANITARY ISOMETRIC AND WATER RISER | | FOR ALL RELOCATED, OR EXTENDED DWV OR WATER | | DISTRIBUTION PIPES- SECTION 107.2.1 WPB. | | | | 2) PLEASE NOTE: | | | | A) THE HORIZONTAL DISTANCE FROM THE CENTERLINE OF THE | | NEW SHOWER DRAIN OUTLET TO THE CENTERLINE OF THE INLET | | OF THE EXISTING TRAPS SHALL NOT EXCEED 30". PLEASE | | PLACE A NOTE ON THE PLAN INDICATING COMPLIANCE- SECTION | | 1002.1 FBC P. | | B) RELOCATING THE SHOWER DRAIN OUTLET MAY REQUIRE THE | | FLOOR TO BE X-RAYED TO IN ORDER TO LOCATE REINFORCING | | STEEL OR POST STRESSED FLOOR TENDONS. PLEASE PLACE A | | NOTE ON THE PLANS TO VERIFY COMPLIANCE WILL BE MET- | | SECTION 107.2.1 WPB. | | C) NEW DRAIN PIPE PENETRATIONS OF THE EXISTING SLAB | | WILL REQUIRE FIRESTOPPING TO SEAL THE ANNULAR SPACE | | AROUND THE PIPING. PROVIDE A UL TESTED AND APPROVED | | FIRESTOPPING ASSEMBLY DETAIL ON THE PLAN- SECTION | | 714.4.1.2 FBC B. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | CHRISTOPHER L. COLE | | MECHANICAL/PLUMBING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
N |
Date |
2020-07-23 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2020-07-23 |
Time |
10:53 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2020-07-23 |
Time |
10:53 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
N |
Date |
2020-07-02 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2020-07-02 |
Time |
09:59 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2020-07-02 |
Time |
09:59 |
Sent To |
|
|
Notes |
2020-07-02 10:00:30 | CONTRACTOR DESIGNED PLANS SIGNED BY CONTRACTOR. |
|
|