Plan Review Stops For Permit 20060547 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2020-07-27 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-07-27 |
Time |
14:55 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-07-27 |
Time |
14:55 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2020-07-20 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-07-20 |
Time |
14:24 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-07-20 |
Time |
14:24 |
Sent To |
|
|
Notes |
2020-07-20 14:25:28 | ROOFING | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected]. | | CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1 | | AMENDMENTS | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | 1) NEW TARCO W-3 DOCUMENTS PROVIDED = ROOFING SYSTEM TO | | BE USED ON THE PROVIDED PRODUCT APPROVAL (W3 AS | | HIGHLITED) REQUIRES ADDITIONAL SIGNED AND SEALED | | ATTACHMENT DETAILS FROM AN ARCHITECT OR ENGINEER FOR | | ROOF WIND ZONES 2 AND 3 WHICH REQUIRE A HIGHER PRESSURE | | THAN THE MAXIMUM SHOWN ON THE PRODUCT APPROVAL (-60) - | | SEE NOTE NUMBER 4 ON THE PRODUCT APPROVAL. SIGNED AND | | SEALED DRAWINGS OR DOCUMENTS WILL NEED TO BE DIGITALLY | | SIGNED AND SEALED TO BE USED IN ELECTRONIC PLAN REVIEW. | | SHOW THE WIND DESIGN DATA USED PER 2017 FBC AND ASCE | | 7-10 - WIND SPEED - EXPOSURE - RISK CATEGORY - ETC. | | SEE FBC R301.1 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2020-07-14 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-07-14 |
Time |
13:22 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-07-14 |
Time |
13:14 |
Sent To |
|
|
Notes |
2020-07-14 13:14:44 | ROOFING | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected]. | | CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1 | | AMENDMENTS | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | 1) NEW TARCO W-3 DOCUMENTS PROVIDED = ROOFING SYSTEM TO | | BE USED ON THE PROVIDED PRODUCT APPROVAL REQUIRES | | ADDITIONAL SIGNED AND SEALED ATTACHMENT DETAILS FROM AN | | ARCHITECT OR ENGINEER FOR ROOF WIND ZONES 2 AND 3 WHICH | | REQUIRE A HIGHER PRESSURE THAN THE MAXIMUM SHOWN ON THE | | PRODUCT APPROVAL (-60) - SEE NOTE NUMBER 4 ON THE | | PRODUCT APPROVAL. SIGNED AND SEALED DRAWINGS OR | | DOCUMENTS WILL NEED TO BE DIGITALLY SIGNED AND SEALED | | TO BE USED IN ELECTRONIC PLAN REVIEW. SHOW THE WIND | | DESIGN DATA USED PER 2017 FBC AND ASCE 7-10 - WIND | | SPEED - EXPOSURE - RISK CATEGORY - ETC. | | 2) PLEASE PROVIDE THE FRONT PAGES FOR THE FLORIDA STATE | | PRODUCT APPROVAL (THE INSTALLATION INSTRUCTIONS ARE | | PROVIDED - FOR TARCO W-3) | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2020-06-17 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-06-17 |
Time |
11:01 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-06-17 |
Time |
10:58 |
Sent To |
|
|
Notes |
2020-06-17 11:01:52 | ROOFING | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected] | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | 1) ROOFING SYSTEM TO BE USED ON THE PROVIDED PRODUCT | | APPROVAL REQUIRES ADDITIONAL SIGNED AND SEALED | | ATTACHMENT DETAILS FROM AN ARCHITECT OR ENGINEER FOR | | ROOF WIND ZONES 2 AND 3 WHICH REQUIRE A HIGHER PRESSURE | | THAN THE MAXIMUM SHOWN ON THE PRODUCT APPROVAL (-60) - | | SEE GEMERAL LIMITATION NOTE NUMBER 7 ON THE PRODUCT | | APPROVAL. SIGNED AND SEALED DRAWINGS OR DOCUMENTS WILL | | NEED TO BE DIGITALLY SIGNED AND SEALED TO BE USED IN | | ELECTRONIC PLAN REVIEW. SHOW THE WIND DESIGN DATA USED | | PER 2017 FBC AND ASCE 7-10 - WIND SPEED - EXPOSURE - | | RISK CATEGORY - ETC. | | | | FYI = ENGINEER CANNOT SELF-CERTIFY THE DIGITAL | | SIGNATURE | | 668.003(2) AND (3), F.S. | | (2) A PROFESSIONAL ENGINEER UTILIZING A DIGITAL | | SIGNATURE TO ELECTRONICALLY SIGN AND SEAL ENGINEERING | | PLANS, | | SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS SHALL HAVE | | THEIR IDENTITY AUTHENTICATED BY A CERTIFICATION | | AUTHORITY. | | |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
2 |
Status |
P |
Date |
2020-07-09 |
|
|
Cont ID |
|
Sent By |
aborngra |
Date |
2020-07-09 |
Time |
11:29 |
Rev Time |
0.00 |
Received By |
aborngra |
Date |
2020-07-09 |
Time |
11:29 |
Sent To |
|
|
Notes |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
P |
Date |
2020-06-18 |
|
|
Cont ID |
|
Sent By |
aborngra |
Date |
2020-06-18 |
Time |
11:43 |
Rev Time |
0.00 |
Received By |
aborngra |
Date |
2020-06-18 |
Time |
11:43 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2020-07-27 |
|
|
Cont ID |
|
Sent By |
ccarvaja |
Date |
2020-07-27 |
Time |
15:46 |
Rev Time |
0.00 |
Received By |
ccarvaja |
Date |
2020-07-22 |
Time |
15:34 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2020-07-20 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-07-20 |
Time |
14:35 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-07-15 |
Time |
09:20 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2020-07-14 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-07-14 |
Time |
13:26 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-07-08 |
Time |
10:26 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2020-06-29 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2020-06-29 |
Time |
14:57 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2020-06-15 |
Time |
13:58 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
4 |
Status |
N |
Date |
2020-07-27 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-07-27 |
Time |
14:55 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-07-27 |
Time |
14:55 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
F |
Date |
2020-07-20 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-07-20 |
Time |
14:28 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-07-20 |
Time |
14:28 |
Sent To |
|
|
Notes |
2020-07-20 14:29:17 | SEE BUILDING PLAN REVIEW |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
F |
Date |
2020-07-14 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-07-14 |
Time |
13:22 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-07-14 |
Time |
13:22 |
Sent To |
|
|
Notes |
2020-07-14 13:26:03 | SEE BUILDING PLAN REVIEW - ANY ADDED SIGNED AND SEALED | | DETAILS FROM AN ARCHITECT OR ENGINEER WILL NEED TO | | FOLLOW THESE REQUIREMENTS - - SIGNED AND SEALED | | DRAWINGS IN PROJECTDOX NEED TO BE | | DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR | | ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW. | | DRAWINGS DO NOT SHOW IN "ADOBE READER" AS | | DIGITALLY/ELECTRONICALLY SIGNED. - OR - IF YOUR | | ENGINEER DOES NOT HAVE AN ELECTRONIC OR DIGITAL | | SIGNATURE - PLEASE DROP OFF (CITY HALL DROP BOX) THE | | ORIGINAL SIGNED AND SEALED DRAWINGS/DOCUMENTS ALONG | | WITH A "PLAN REVIEW REQUEST FORM" EXPLAINING THE REASON | | FOR SUBMITTING THE DOCUMENT OR DRAWINGS. PLAN REVIEW | | REQUEST FORM CAN BE OBTAINED BY E MAILING [email protected] | | AND ASKING FOR THE FORM. (AT THIS TIME DROP BOX ITEMS | | MAY TAKE 2 TO 3 WEEKS TO PROCESS - DUE TO LIMITED STAFF | | INSIDE THE BUILDING DEPT.) |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2020-06-17 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-06-17 |
Time |
11:02 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-06-17 |
Time |
11:02 |
Sent To |
|
|
Notes |
2020-06-17 11:02:38 | SEE BUILDING PLAN REVIEW |
|
|