Plan Review Details - Permit 20060547
Plan Review Stops For Permit 20060547
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2020-07-27 Cont ID  
Sent By rmcphers Date 2020-07-27 Time 14:55 Rev Time 0.00
Received By rmcphers Date 2020-07-27 Time 14:55 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2020-07-20 Cont ID  
Sent By rmcphers Date 2020-07-20 Time 14:24 Rev Time 0.00
Received By rmcphers Date 2020-07-20 Time 14:24 Sent To  
Notes
2020-07-20 14:25:28ROOFING
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected].
 CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1
 AMENDMENTS
  
 CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107
 1) NEW TARCO W-3 DOCUMENTS PROVIDED = ROOFING SYSTEM TO
 BE USED ON THE PROVIDED PRODUCT APPROVAL (W3 AS
 HIGHLITED) REQUIRES ADDITIONAL SIGNED AND SEALED
 ATTACHMENT DETAILS FROM AN ARCHITECT OR ENGINEER FOR
 ROOF WIND ZONES 2 AND 3 WHICH REQUIRE A HIGHER PRESSURE
 THAN THE MAXIMUM SHOWN ON THE PRODUCT APPROVAL (-60) -
 SEE NOTE NUMBER 4 ON THE PRODUCT APPROVAL. SIGNED AND
 SEALED DRAWINGS OR DOCUMENTS WILL NEED TO BE DIGITALLY
 SIGNED AND SEALED TO BE USED IN ELECTRONIC PLAN REVIEW.
 SHOW THE WIND DESIGN DATA USED PER 2017 FBC AND ASCE
 7-10 - WIND SPEED - EXPOSURE - RISK CATEGORY - ETC.
 SEE FBC R301.1

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2020-07-14 Cont ID  
Sent By rmcphers Date 2020-07-14 Time 13:22 Rev Time 0.00
Received By rmcphers Date 2020-07-14 Time 13:14 Sent To  
Notes
2020-07-14 13:14:44ROOFING
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected].
 CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1
 AMENDMENTS
  
 CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107
 1) NEW TARCO W-3 DOCUMENTS PROVIDED = ROOFING SYSTEM TO
 BE USED ON THE PROVIDED PRODUCT APPROVAL REQUIRES
 ADDITIONAL SIGNED AND SEALED ATTACHMENT DETAILS FROM AN
 ARCHITECT OR ENGINEER FOR ROOF WIND ZONES 2 AND 3 WHICH
 REQUIRE A HIGHER PRESSURE THAN THE MAXIMUM SHOWN ON THE
 PRODUCT APPROVAL (-60) - SEE NOTE NUMBER 4 ON THE
 PRODUCT APPROVAL. SIGNED AND SEALED DRAWINGS OR
 DOCUMENTS WILL NEED TO BE DIGITALLY SIGNED AND SEALED
 TO BE USED IN ELECTRONIC PLAN REVIEW. SHOW THE WIND
 DESIGN DATA USED PER 2017 FBC AND ASCE 7-10 - WIND
 SPEED - EXPOSURE - RISK CATEGORY - ETC.
 2) PLEASE PROVIDE THE FRONT PAGES FOR THE FLORIDA STATE
 PRODUCT APPROVAL (THE INSTALLATION INSTRUCTIONS ARE
 PROVIDED - FOR TARCO W-3)
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-06-17 Cont ID  
Sent By rmcphers Date 2020-06-17 Time 11:01 Rev Time 0.00
Received By rmcphers Date 2020-06-17 Time 10:58 Sent To  
Notes
2020-06-17 11:01:52ROOFING
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
  
 CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107
 1) ROOFING SYSTEM TO BE USED ON THE PROVIDED PRODUCT
 APPROVAL REQUIRES ADDITIONAL SIGNED AND SEALED
 ATTACHMENT DETAILS FROM AN ARCHITECT OR ENGINEER FOR
 ROOF WIND ZONES 2 AND 3 WHICH REQUIRE A HIGHER PRESSURE
 THAN THE MAXIMUM SHOWN ON THE PRODUCT APPROVAL (-60) -
 SEE GEMERAL LIMITATION NOTE NUMBER 7 ON THE PRODUCT
 APPROVAL. SIGNED AND SEALED DRAWINGS OR DOCUMENTS WILL
 NEED TO BE DIGITALLY SIGNED AND SEALED TO BE USED IN
 ELECTRONIC PLAN REVIEW. SHOW THE WIND DESIGN DATA USED
 PER 2017 FBC AND ASCE 7-10 - WIND SPEED - EXPOSURE -
 RISK CATEGORY - ETC.
  
 FYI = ENGINEER CANNOT SELF-CERTIFY THE DIGITAL
 SIGNATURE
 668.003(2) AND (3), F.S.
 (2) A PROFESSIONAL ENGINEER UTILIZING A DIGITAL
 SIGNATURE TO ELECTRONICALLY SIGN AND SEAL ENGINEERING
 PLANS,
 SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS SHALL HAVE
 THEIR IDENTITY AUTHENTICATED BY A CERTIFICATION
 AUTHORITY.
  

Review Stop HIST HISTORICAL
Rev No 2 Status P Date 2020-07-09 Cont ID  
Sent By aborngra Date 2020-07-09 Time 11:29 Rev Time 0.00
Received By aborngra Date 2020-07-09 Time 11:29 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2020-06-18 Cont ID  
Sent By aborngra Date 2020-06-18 Time 11:43 Rev Time 0.00
Received By aborngra Date 2020-06-18 Time 11:43 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2020-07-27 Cont ID  
Sent By ccarvaja Date 2020-07-27 Time 15:46 Rev Time 0.00
Received By ccarvaja Date 2020-07-22 Time 15:34 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2020-07-20 Cont ID  
Sent By rmcphers Date 2020-07-20 Time 14:35 Rev Time 0.00
Received By rmcphers Date 2020-07-15 Time 09:20 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-07-14 Cont ID  
Sent By rmcphers Date 2020-07-14 Time 13:26 Rev Time 0.00
Received By rmcphers Date 2020-07-08 Time 10:26 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-06-29 Cont ID  
Sent By shill Date 2020-06-29 Time 14:57 Rev Time 0.00
Received By shill Date 2020-06-15 Time 13:58 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 4 Status N Date 2020-07-27 Cont ID  
Sent By rmcphers Date 2020-07-27 Time 14:55 Rev Time 0.00
Received By rmcphers Date 2020-07-27 Time 14:55 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status F Date 2020-07-20 Cont ID  
Sent By rmcphers Date 2020-07-20 Time 14:28 Rev Time 0.00
Received By rmcphers Date 2020-07-20 Time 14:28 Sent To  
Notes
2020-07-20 14:29:17SEE BUILDING PLAN REVIEW

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2020-07-14 Cont ID  
Sent By rmcphers Date 2020-07-14 Time 13:22 Rev Time 0.00
Received By rmcphers Date 2020-07-14 Time 13:22 Sent To  
Notes
2020-07-14 13:26:03SEE BUILDING PLAN REVIEW - ANY ADDED SIGNED AND SEALED
 DETAILS FROM AN ARCHITECT OR ENGINEER WILL NEED TO
 FOLLOW THESE REQUIREMENTS - - SIGNED AND SEALED
 DRAWINGS IN PROJECTDOX NEED TO BE
 DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR
 ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW.
 DRAWINGS DO NOT SHOW IN "ADOBE READER" AS
 DIGITALLY/ELECTRONICALLY SIGNED. - OR - IF YOUR
 ENGINEER DOES NOT HAVE AN ELECTRONIC OR DIGITAL
 SIGNATURE - PLEASE DROP OFF (CITY HALL DROP BOX) THE
 ORIGINAL SIGNED AND SEALED DRAWINGS/DOCUMENTS ALONG
 WITH A "PLAN REVIEW REQUEST FORM" EXPLAINING THE REASON
 FOR SUBMITTING THE DOCUMENT OR DRAWINGS. PLAN REVIEW
 REQUEST FORM CAN BE OBTAINED BY E MAILING [email protected]
 AND ASKING FOR THE FORM. (AT THIS TIME DROP BOX ITEMS
 MAY TAKE 2 TO 3 WEEKS TO PROCESS - DUE TO LIMITED STAFF
 INSIDE THE BUILDING DEPT.)

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2020-06-17 Cont ID  
Sent By rmcphers Date 2020-06-17 Time 11:02 Rev Time 0.00
Received By rmcphers Date 2020-06-17 Time 11:02 Sent To  
Notes
2020-06-17 11:02:38SEE BUILDING PLAN REVIEW