Plan Review Stops For Permit 20060389 |
Review Stop |
AD |
ADDRESSING |
Rev No |
2 |
Status |
F |
Date |
2020-08-11 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2020-08-11 |
Time |
08:15 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2020-08-11 |
Time |
08:15 |
Sent To |
|
|
Notes |
2020-08-11 08:15:31 | PER BUILDING COMMENTS, PLEASE INDICATE IF THE WORK TO | | BE DONE IS THE EAST OR WEST BUILDING. PLEASE EMAIL | | [email protected] |
|
|
Review Stop |
AD |
ADDRESSING |
Rev No |
1 |
Status |
F |
Date |
2020-07-23 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2020-07-23 |
Time |
12:11 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2020-07-23 |
Time |
12:11 |
Sent To |
|
|
Notes |
2020-07-23 12:12:05 | PER BUILDING COMMENTS, PLEASE INDICATE IF THE WORK TO | | BE DONE IS THE EAST OR WEST BUILDING. PLEASE EMAIL | | [email protected] |
|
|
Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
Rev No |
3 |
Status |
P |
Date |
2020-09-01 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-09-01 |
Time |
08:40 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-09-01 |
Time |
08:40 |
Sent To |
|
|
Notes |
|
|
Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
Rev No |
2 |
Status |
F |
Date |
2020-08-05 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2020-08-05 |
Time |
11:43 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2020-08-05 |
Time |
11:01 |
Sent To |
|
|
Notes |
2020-08-05 11:38:48 | COMMERCIAL ASBESTOS | | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | CONTRACTOR, ON LETTERHEAD, STATING THAT THE | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | COUNTY WILL BE FOLLOWED AND THAT NOTIFICATION WILL BE | | GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS | | REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE: | | | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | RENOVATION.HTML | | | | THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO | | [email protected]. THE INFORMATION SHOULD BE IN PDF | | FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE INCLUDE | | THE PERMIT NUMBER AND ?ASBESTOS? IN THE SUBJECT LINE. | | | | |
|
|
Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
Rev No |
1 |
Status |
F |
Date |
2020-06-14 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2020-06-14 |
Time |
13:48 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2020-06-14 |
Time |
13:47 |
Sent To |
|
|
Notes |
2020-06-14 13:48:26 | ASBESTOS COMMERCIAL. | | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | CONTRACTOR, ON LETTERHEAD, STATING THAT THE | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | COUNTY WILL BE FOLLOWED AND THAT NOTIFICATION WILL BE | | GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS | | REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE: | | | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | RENOVATION.HTML | | 19120504 | | THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO | | [email protected]. THE INFORMATION SHOULD BE IN PDF | | FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE INCLUDE | | THE PERMIT NUMBER AND ?ASBESTOS? IN THE SUBJECT LINE. | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2020-09-01 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2020-09-01 |
Time |
07:43 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2020-09-01 |
Time |
06:57 |
Sent To |
|
|
Notes |
2020-09-01 07:43:54 | 2017 FBC- BUILDING PLAN REVIEW | | W. P. B. PERMIT: 20060389 | | ADD: 2401 MERCER AVE. | | CONT: BUTLER CONSTRUCTION | | TEL: 561-832-9700 | | E-MAIL: [email protected] | | | | 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION | | | | 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | BUILDING CODE, BUILDING. | | | | 3RD REVIEW | | DATE: TUES. SEPT. 01ST/ 2020 | | ACTION: BUILDING PROVISO | | | | 1) THE SUBMITTED PERMIT APPLICATION STATES THAT IT IS | | FOR THE RENOVATION OF AN EXISTING RESTROOM FOR A VALUE | | OF $5,000.00 DOLLARS. THE CONTRACTOR SHALL INCREASE THE | | DOLLAR AMONT TO A MARKET VALUE BEFORE PERMIT ISSUANCE. | | A HOLD WILLBE PUT ON THE ISSUANCE OF THE PERMIT UNTIL | | VALUE IS INCREASED. | | JAMES A. WITMER BN, PX, SFP, CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | TEL: 561-805-6717 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2020-08-05 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2020-08-05 |
Time |
11:43 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2020-08-05 |
Time |
11:01 |
Sent To |
|
|
Notes |
2020-08-05 11:37:42 | 2017 FBC- BUILDING PLAN REVIEW | | W. P. B. PERMIT: 20060389 | | ADD: 2401 MERCER AVE. | | CONT: BUTLER CONSTRUCTION | | TEL: 561-832-9700 | | E-MAIL: [email protected] | | | | 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION | | | | 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | BUILDING CODE, BUILDING. | | | | 2ND REVIEW | | DATE: WED. AUGUST 05TH/ 2020 | | ACTION: DENIED | | | | 1A) 2ND REQUEST. THE SUBMITTED PERMIT APPLICATION | | STATES THAT IT IS FOR THE RENOVATION OF AN EXISTING | | RESTROOM FOR A VALUE OF $5,000.00 DOLLARS. THE PERMIT | | APPLICATION DOES NOT STATE IF THE WORK TO BE PERFORMED | | UNDER THIS PERMIT IS IN BUILDING A OR BUILDING B? NOR | | THE RESPONSE LETTER. | | | | 1B) 2ND REQUEST. TO FURTHER CONFUSE THE JOBSITE | | LOCATION IN THE TITLEBLOCK THE LOCATION STATES 2401 | | MERCER BUILDING B. THE LIFE SAFETY SHEET A-1 UNDER THE | | FLOOR PLAN STATES BUILDING A, WHICH IS IT? THE LOCATION | | OF WHERE THIS PROJECT IS TO TAKE PLACE IS IN QUESTION? | | 2017 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION 107.2.1 INFORMATION ON CONSTRUCTION | | DOCUMENTS. CONSTRUCTION DOCUMENTS SHALL BE OF | | SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND | | EXTENT OF THE WORK PROPOSED. | | | | 2) COMPLIED. | | 3) SHEET A-2 DOES MAKE REFERENCE TO THIS FACILITY IS A | | PUBLIC CHARTER SCHOOL GRADES K-8TH GRADE. PLEASE BE | | AWARE OF THE 2017 FBC-EXISTING BUILDING CODE SCOPING | | REQUIREMENTS AND THE EXCEPTION FOUND UNDER SECTION | | 101.2. EXCEPTION: FOR THE PURPOSE OF PUBLIC EDUCATIONAL | | FACILITIES AND STATE LICENSED FACILITIES, SEE CHAPTER | | 4, SPECIAL OCCUPANCIES, OF THE FLORIDA BUILDING CODE, | | BUILDING. | | SECTION 453 DEALS WITH STATE REQUIREMENTS FOR | | EDUCATIONAL FACILITIES. NOT THE LOCAL BUILDING | | DEPARTMENT CONCERN UNLESS THE SCHOOL BOARD SUBMITS | | PLANS FOR PUBLIC SCHOOLS. | | | | 3A) THIS COMMENT IS GOING TO BE REVIEWED BY THE | | ASSISTANT BUILDING OFFICIAL RICHARD GATHRIGHT FOR | | INTERPRETATION. ENTERED IN COMPUTER TODAY 8/05/2020. J. | | W. | | | | SECTION 468.1 IS FOR FLORIDA?S PUBLIC AND PRIVATE | | SCHOOLS, COLLEGES AND UNIVERSITIES. THERE IS NO | | EXISTING BUILDING CODE TO GO BY UNDER SPECIAL | | OCCUPANCIES FOUND IN CHAPTER 4. THERE IS NOT ENOUGH | | INFORMATION ON THE PLAN TO DETERMINE CODE COMPLIANCE | | FOR CODE COMPLIANCE FOR THE REQUIRED NUMBER OF FIXTURES | | REQUIRED UNDER THE 2017 FBC-B TABLE 2902.1 FOR | | EDUCATION. | | | | 3B) COMPLIED. | | | | 4) COMPLIED. | | | | 5) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID | | 19 IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS | | 561-718-9724. | | | | JAMES A. WITMER BN, PX, CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT | | 401 CLEMATIS ST. | | WEST PALM BEACH. FL 33402 | | TEL: 561-805-6717 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2020-06-14 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2020-06-14 |
Time |
15:40 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2020-06-14 |
Time |
13:47 |
Sent To |
|
|
Notes |
2020-06-14 15:39:48 | 2017 FBC- BUILDING PLAN REVIEW | | W. P. B. PERMIT: 20060389 | | ADD: 2401 MERCER AVE. | | CONT: BUTLER CONSTRUCTION | | TEL: 561-832-9700 | | E-MAIL: [email protected] | | | | 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION | | | | 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | BUILDING CODE, BUILDING. | | | | 1ST REVIEW | | DATE: SUN. JUNE 14TH/ 2020 | | ACTION: DENIED | | | | 1) THE SUBMITTED PERMIT APPLICATION STATES THAT IT IS | | FOR THE RENOVATION OF AN EXISTING RESTROOM FOR A VALUE | | OF $5,000.00 DOLLARS. THE PERMIT APPLICATION DOES NOT | | STATE IF THE WORK TO BE PERFORMED UNDER THIS PERMIT IS | | IN BUILDING A OR BUILDING B? TO FURTHER CONFUSE THE | | JOBSITE LOCATION IN THE TITLEBLOCK THE LOCATION STATES | | 2401 MERCER BUILDING B. THE LIFE SAFETY SHEET A-1 UNDER | | THE FLOOR PLAN STATES BUILDING A, WHICH IS IT? THE | | LOCATION OF WHERE THIS PROJECT IS TO TAKE PLACE IS IN | | QUESTION? | | 2017 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION 107.2.1 INFORMATION ON CONSTRUCTION | | DOCUMENTS. CONSTRUCTION DOCUMENTS SHALL BE OF | | SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND | | EXTENT OF THE WORK PROPOSED. | | | | 2) SHEET A-1 CODE REFERENCES LIST THE 2014 FBC AS THE | | CODE IN AFFECT. PLEASE UPDATE THE CODE REFERENCE TO THE | | 2017 FBC. THE 2017 FAMILY OF THE 6TH EDITION FLORIDA | | BUILDING CODE HAS BEEN ADOPTED STATEWIDE SINCE | | 12/31/2017. | | | | 3) SHEET A-2 DOES MAKE REFERENCE TO THIS FACILITY IS A | | PUBLIC CHARTER SCHOOL GRADES K-8TH GRADE. PLEASE BE | | AWARE OF THE 2017 FBC-EXISTING BUILDING CODE SCOPING | | REQUIREMENTS AND THE EXCEPTION FOUND UNDER SECTION | | 101.2. EXCEPTION: FOR THE PURPOSE OF PUBLIC EDUCATIONAL | | FACILITIES AND STATE LICENSED FACILITIES, SEE CHAPTER | | 4, SPECIAL OCCUPANCIES, OF THE FLORIDA BUILDING CODE, | | BUILDING. | | SECTION 453 DEALS WITH STATE REQUIREMENTS FOR | | EDUCATIONAL FACILITIES. NOT THE LOCAL BUILDING | | DEPARTMENT CONCERN UNLESS THE SCHOOL BOARD SUBMITS | | PLANS FOR PUBLIC SCHOOLS. | | | | 3A) SECTION 468.1 IS FOR FLORIDA?S PUBLIC AND PRIVATE | | SCHOOLS, COLLEGES AND UNIVERSITIES. THERE IS NO | | EXISTING BUILDING CODE TO GO BY UNDER SPECIAL | | OCCUPANCIES FOUND IN CHAPTER 4. THERE IS NOT ENOUGH | | INFORMATION ON THE PLAN TO DETERMINE CODE COMPLIANCE | | FOR CODE COMPLIANCE FOR THE REQUIRED NUMBER OF FIXTURES | | REQUIRED UNDER THE 2017 FBC-B TABLE 2902.1 FOR | | EDUCATION. | | | | 3B) 2017 FBC-B 468.3.5.1 STANDARDS. EDUCATIONAL AND | | ANCILLARY FACILITIES SHALL BE PROVIDED WITH TOILETS, | | HAND WASHING FACILITIES AND DRINKING FOUNTAINS FOR ALL | | OCCUPANTS IN RATIOS AND ACCESSIBLE AS REQUIRED BY THE | | FLORIDA BUILDING CODE, FLORIDA LAW AND FEDERAL | | REGULATIONS. SHEET A-1 SHOWS A SINGLE DRINKING FOUNTAIN | | NOT A HIGH-LOW DRINKING FOUNTAIN AS REQUIRED BY: | | 2017 FBC-ACCESSIBILITY CODE. 211.2 MINIMUM NUMBER. NO | | FEWER THAN TWO DRINKING FOUNTAINS SHALL BE PROVIDED. | | ONE DRINKING FOUNTAIN SHALL COMPLY WITH 602.1 THROUGH | | 602.6 AND ONE DRINKING FOUNTAIN SHALL COMPLY WITH | | 602.7. | | DRINKING FOUNTAINS TO SHOW COMPLIANCE WITH 307.2 | | PROTRUSION LIMITS. OBJECTS WITH LEADING EDGES MORE THAN | | 27 INCHES AND NOT MORE THAN 80 INCHES ABOVE THE FINISH | | FLOOR SHALL PROTRUDE 4 INCHES OR LESS MAXIMUM | | HORIZONTALLY INTO THE CIRCULATION PATH. SKIRTS MAYBE | | REQUIRED TO BE APPLIED TO THE BOTTOM OF THE DRINKING | | FOUNTAIN. | | | | 4) SHEET A-3 HAS RESTROOM DETAILS, THE GRAB BARS THAT | | SURROUND THE WATER CLOSET NEED TO BE UPDATED TO THE | | 2017 FBC-ACCESSIBILITY CODE. 2017 FBC-ACCESSIBILITY | | CODE SECTION 609.4 POSITION OF GRAB BARS. GRAB BARS | | SHALL BE INSTALLED IN A HORIZONTAL POSITION, 33 INCHES | | MINIMUM AND 36 INCHES MAXIMUM ABOVE THE FINISH FLOOR | | MEASURED TO THE TOP OF THE GRIPPING SURFACE, NOT | | CENTERLINE. | | | | 5) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | A THOROUGH REVIEW OF THE PLANS COULD NOT HAPPEN SINCE | | THERE WAS A GREAT DEFICIENCY IN PLANS AND REQUIRED | | DOCUMENTATION. WITH THE NEXT PLAN REVIEW CYCLE THERE | | MAYBE ADDITIONAL REVIEW COMMENTS BECAUSE OF NEW PLANS | | AND INFORMATION LACKING UNDER THE PRIOR REVIEW. | | | | PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID | | 19 IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS | | 561-718-9724. | | | | JAMES A. WITMER BN, PX, SFP, CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | TEL: 561-805-6717 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
P |
Date |
2020-10-05 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2020-10-05 |
Time |
16:26 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2020-10-05 |
Time |
16:23 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
F |
Date |
2020-09-10 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2020-09-10 |
Time |
15:21 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2020-09-10 |
Time |
15:09 |
Sent To |
|
|
Notes |
2020-09-10 15:23:25 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | FLORIDA BUILDING CODE 2017 6TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | NFPA 70 2014 EDITION | | | | JAKE LEAHY BN, BU, PX | | ELECTRICAL PLANS EXAMINER II | | 561-805-6713 | | [email protected] | | | | PLEASE INDICATE ANY NEW OR MOVED ELECTRICAL OUTLETS ON | | PLAN FOR REVIEW. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2020-08-10 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2020-08-10 |
Time |
17:32 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2020-08-10 |
Time |
17:26 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2020-06-29 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2020-06-29 |
Time |
15:02 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2020-06-29 |
Time |
15:02 |
Sent To |
|
|
Notes |
2020-06-29 15:04:14 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2014 5TH EDITION | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 | | 5TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION, | | PART VIII ELECTRICAL | | NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | FLORIDA BUILDING CODE 2017 6TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | NFPA 70 2014 EDITION | | | | JAKE LEAHY BN, BU, PX | | ELECTRICAL PLANS EXAMINER II | | 561-805-6713 | | [email protected] | | | | | | NO ELECTRIC SHOWN FOR BATHROOM. PLEASE INDICATE ON | | DRAWING WHAT ELECTRIC IS TO BE INSTALLED IN NEW | | BATHROOM. |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2020-09-02 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2020-09-02 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2020-09-02 |
Time |
14:50 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2020-07-28 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2020-07-28 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2020-07-28 |
Time |
09:33 |
Sent To |
|
|
Notes |
2020-07-28 09:33:13 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED | | AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE | | PROVISO COMMENTS WILL RESULT IN A FAILED FIRE | | INSPECTION. | | | | 1) ANY REMOVAL AND/OR CONSTRUCTION OF WALLS AND /OR | | CEILINGS MAY REQUIRE AN EVALUATION OF THE FIRE ALARM | | SYSTEM OR DEVICES FOR CODE COVERAGE AND COMPLIANCE BY | | CERTIFIED CONTRACTORS. | | | | 2) ANY AND ALL WORK ON THE FIRE ALARM SYSTEM/EQUIPMENT | | SHALL BE DONE UNDER SEPARATE PERMIT AND SHOP DRAWINGS | | BY CERTIFIED CONTRACTORS. | | | | 3) THE FIRE ALARM SYSTEM SHALL REMAIN ACTIVE THROUGHOUT | | THE CONSTRUCTION PERIOD. | | | | PETER LEDUC | | FIRE MARSHAL | | WEST PALM BEACH FIRE RESCUE | | 561-804-4709 | | [email protected] | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2020-06-12 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2020-06-12 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2020-06-12 |
Time |
12:50 |
Sent To |
|
|
Notes |
2020-06-12 12:52:33 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED | | AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE | | PROVISO COMMENTS WILL RESULT IN A FAILED FIRE | | INSPECTION. | | | | 1) ANY REMOVAL AND/OR CONSTRUCTION OF WALLS AND /OR | | CEILINGS MAY REQUIRE AN EVALUATION OF THE FIRE ALARM | | SYSTEM OR DEVICES FOR CODE COVERAGE AND COMPLIANCE BY | | CERTIFIED CONTRACTORS. | | | | 2) ANY AND ALL WORK ON THE FIRE ALARM SYSTEM/EQUIPMENT | | SHALL BE DONE UNDER SEPARATE PERMIT AND SHOP DRAWINGS | | BY CERTIFIED CONTRACTORS. | | | | 3) THE FIRE ALARM SYSTEM SHALL REMAIN ACTIVE THROUGHOUT | | THE CONSTRUCTION PERIOD. | | | | PETER LEDUC | | FIRE MARSHAL | | WEST PALM BEACH FIRE RESCUE | | 561-804-4709 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2020-10-05 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2020-10-05 |
Time |
16:26 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2020-09-24 |
Time |
14:59 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2020-09-10 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2020-09-10 |
Time |
15:23 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2020-08-31 |
Time |
09:26 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2020-08-11 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2020-08-11 |
Time |
08:15 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2020-07-27 |
Time |
09:43 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2020-07-02 |
Time |
|
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2020-06-11 |
Time |
14:39 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
F |
Date |
2020-09-28 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2020-09-28 |
Time |
07:30 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2020-09-28 |
Time |
06:52 |
Sent To |
|
|
Notes |
2020-09-28 07:31:04 | 3RD REVIEW FBC-2017 MECHANICAL | | PERMIT-20060389 | | | | CODES IN EFFECT: | | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | 2017 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2017 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) PLEASE SEE BUILDING B SQ. FT. SUMMARY ON SHEET A-1. | | AFTER CARE ASSEMBLY AREA HAS AN OCCUPANT LOAD OF 72 | | PEOPLE. PLEASE USE THIS OCCUPANT COUNT FOR THE OUTDOOR | | AIR CALCULATIONS FOR THE AFTER CARE ROOM ON SHEET A-4. | | WE MUST PROVIDE O.A. BASED ON THE OCCUPANT LOAD OF THE | | SPACE. FBC M TABLE 403.3.1.1 | | | | 2) BASED ON FBC M TABLE 403.3.1.1: REQUIRED O.A. FOR | | THIS BUILDING IS: AFTER CARE ROOM- 605 CFM; 4 | | CLASSROOMS- 1007CFM. SHEET A-4- THE DRAWING SHOWS AN | | O.A. DUCT FOR EXISTING AHU#1 BUT THE OUTDOOR AIR | | CALCULATIONS DO NOT SHOW THE REQUIRED OUTDOOR AIR FOR | | THIS ROOM. PLEASE SHOW THIS IN THE O.A. CALCULATIONS. | | FBC M TABLE 403.3.1.1 | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD | | SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER | | SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN | | THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS | | PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS | | PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR | | UPDATED. | | | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2020-09-08 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2020-09-08 |
Time |
14:02 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2020-09-08 |
Time |
11:59 |
Sent To |
|
|
Notes |
2020-09-08 14:02:53 | 2ND REVIEW FBC-2017 MECHANICAL | | PERMIT-20060389 | | | | CODES IN EFFECT: | | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | 2017 | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | 2017 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2017 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) PROVIDE A O.A. CALCULATION BASED ON THE OCCUPANT | | COUNT FOR EACH ROOM SHOWN ON SHEET A-1. FBC M 403.3.1.1 | | | | 2) PLEASE PROVIDE O.A. CALCULATIONS FOR THE | | ADMIN/SUPPLY ROOM AND THE ROOM ADJACENT TO IT. FBC FS | | 107.2.1 | | | | 3) THE O.A. CALCULATIONS APPEAR TO BE LOW BASED ON | | TABLE 403.3.1.1- CLASS ROOMS (AGE 9 PLUS) AND THE | | AFTER-SCHOOL DAY CARE (MULTI-USE ASSEMBLY). THESE | | NUMBERS ARE BASED ON OCCUPANCY OF ROOMS ON SHEET A-1. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD | | SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER | | SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN | | THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS | | PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS | | PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR | | UPDATED. | | | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2020-08-12 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2020-08-12 |
Time |
14:05 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2020-08-12 |
Time |
14:04 |
Sent To |
|
|
Notes |
2020-08-12 14:06:04 | 1ST REVIEW FBC-2017 MECHANICAL | | PERMIT-20060393 | | | | CODES IN EFFECT: | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | 2017 | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | 2017 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2017 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) THIS APPEARS TO BE A CHANGE OF OCCUPANCY FROM A | | BUSINESS TO EDUCATION. | | | | 2) PLEASE PROVIDE MECHANICAL SHEETS, BOTH DEMO AND NEW | | WORK SHEETS. FBC FS 107.2.1 | | | | 3) PLEASE PROVIDE MECHANICAL VENTILATION CALCULATIONS | | FOR EACH CLASSROOM AND EACH AREA OF THIS SPACE. VERIFY | | THE EXISTING MECHANICAL SYSTEM IS ADEQUATE FOR THIS NEW | | CHANGE OF OCCUPANCY. FBC M TABLE 403.3.1.1 | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD | | SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER | | SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN | | THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS | | PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS | | PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR | | UPDATED. | | | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2020-09-02 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2020-09-02 |
Time |
10:02 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2020-09-02 |
Time |
09:19 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2020-08-04 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2020-08-04 |
Time |
17:34 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2020-08-04 |
Time |
14:06 |
Sent To |
|
|
Notes |
2020-08-04 17:36:49 | 2ND REVIEW FBC-2017 PLUMBING | | PERMIT- 20060389 | | 8/4/2020 | | | | CODES IN EFFECT: | | FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017 | | FBC ACC- FLORIDA ACCESSIBILITY CODE SIXTH ADDITION 2017 | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | 2017 | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | 2017 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2017 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) SHEET A3: REMOVE THE REFERENCES TO THE FBC 2007 | | SHOWN IN DETAIL 6. THE ACCESSIBLE TOILET ROOM SHALL BE | | DESIGNED IN ACCORDANCE WITH THE FLORIDA ACCESSIBILITY | | CODE- 2017 SIXTH EDITION. | | | | A) DETAIL 6 GRAB BARS: REFER TO FIGURE 604.5.2 FBC ACC | | AND CORRECT THE REAR WALL GRAB BAR DETAIL. | | | | B) 2ND REQUEST FOR LOCATION, MOUNTING HEIGHT AND | | CLEARANCE FOR THE TOILET PAPER DISPENSER- SECTION | | 604.7. | | | | C) REFER TO FIGURES 306.2 AND 306.3 AND CORRECT THE | | KNEE AND TOE CLEARANCES FOR THE LAVATORY. TOE | | CLEARANCES SHALL BE MINIMUM 9" IN HEIGHT, AND KNEE | | CLEARANCE SHALL BE 11" DEEP MINIMUM AT 9" ABOVE THE | | FINISHED FLOOR- SECTION 306.3.3. | | | | 2) COMMENTS #5,6,7, & 8 FROM THE 1ST REVIEW LISTED | | BELOW HAVE NOT BEEN ADDRESSED- PLEASE COMPLY. | | 5) A3: PROVIDE A WATER RISER DRAWING SHOWING PIPE | | SIZES, LOCATIONS OF SHUTOFF VALVES, WATER HAMMER | | ARRESTORS, MIXING VALVES ETC.- SECTION 107.3.5.1.3 WPB | | AMENDMENTS TO THE FBC. NOT PROVIDED. | | | | 6) A3: PROVIDE PLUMBING FIXTURE AND DEVICE SCHEDULES ON | | THE PLAN- SECTION 107.2.1 WPB & SECTION 405.9. NOT | | PROVIDED. | | | | 7) A3: INDICATE HOW TEMPERED WATER WILL BE PROVIDED TO | | THE LAVATORY- SECTION 416.5 FBC P. NOT PROVIDED. | | | | 8) A1 & A3: PROVIDE THE SCOPE OF WORK FOR THE REQUIRED | | WATER HEATER- SECTION 607.1 FBC P. CLARIFY IF THE | | APPLIANCE IS EXISTING OR TO BE REPLACED. SHOW THE | | LOCATION AND PROVIDE PLUMBING DETAILS IF APPLICABLE. | | PLEASE NOTE THAT THE DEVELOPED LENGTH OF HOT OR | | TEMPERED WATER PIPING, FROM THE SOURCE OF HOT WATER TO | | THE FIXTURES THAT REQUIRE HOT OR TEMPERED WATER, SHALL | | NOT EXCEED 50 FEET. | | THE WATER HEATER DETAIL ON A3 DOES NOT SPECIFY A MAKE | | AND MODEL, GALLON SIZE, OR EFFICIENCY RATING. | | NOTE-7 SPECIFIES A MIXING VALVE BUT INCORRECT LISTING- | | ASSE 1070 CONFORMANCE REQUIRED- SECTION 607.1.2 FBC P. | | NOTE-8 INDICATES MIXING VALVE TEMPERATURE SETTING AT | | 140 DEGREES. TEMPERED WATER SHALL HAVE A TEMPERATURE | | RANGE 0F 85 TO 110 DEGREES FAHRENHEIT. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | CHRISTOPHER L. COLE | | MECHANICAL/PLUMBING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2020-07-02 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2020-07-02 |
Time |
11:45 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2020-07-02 |
Time |
10:03 |
Sent To |
|
|
Notes |
2020-07-02 11:48:41 | 1ST REVIEW FBC-2017 PLUMBING | | PERMIT- 20060389 | | 7/2/2020 | | | | CODES IN EFFECT: | | FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017 | | FBC ACC- FLORIDA ACCESSIBILITY CODE SIXTH ADDITION 2017 | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | 2017 | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | 2017 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2017 | | PLAN REVIEW RESULTS: DENIED. | | | | 1) SHEET A1: REFER TO SECTION 468.3.5.1 FBC B, AND | | TABLE 403.3 FBC P AND PROVIDE PLUMBING FIXTURE | | CALCULATIONS. PROVIDE A SCHEDULE ON THE PLAN INDICATING | | THE REQUIRED AND PROVIDED PLUMBING FIXTURE BASED ON THE | | E OCCUPANCY AND OCCUPANT LOAD OF 183. PLEASE NOTE THAT | | A MINIMUM OF TWO DRINKING FOUNTAINS ARE REQUIRED- REFER | | TO SECTION 211.1- 2113 FBC ACC PLEASE NOTE A THOROUGH | | REVIEW OF THE PLANS CANNOT BE ACCOMPLISHED UNTIL THE | | SCHEDULE IS PROVIDED- SECTION 107.2.1 WPB. | | | | 2) A1, A2: IDENTIFY THE NEW TOILET ROOM AS EITHER MALE | | OR FEMALE- SECTION 403.2 FBC P. | | | | 3) A3: PROVIDE ENLARGED TOILET ROOM DRAWINGS | | INDICATING: | | A) CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS FOR THE | | WATER CLOSET- SECTION 604.3. | | B) CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS FOR THE | | LAVATORY- SECTION 606.2. | | C) TURNING SPACE DIAMETER- SECTION 304.3. | | D) LOCATION OF THE WATER CLOSET FLUSH CONTROL- SECTION | | 604.6. | | E) LOCATION, CLEARANCE, AND MOUNTING HEIGHT FOR THE | | TOILET PAPER DISPENSER- SECTION 604.7. | | | | 4) A3: THE SINK FIXTURE DRAIN MUST CONNECT TO THE 3" | | BUILDING DRAIN DOWNSTREAM OF THE WC AND LAVATORY PER | | SECTIONS 912.1 AND 912.2.1 FBC P. | | | | 5) A3: PROVIDE A WATER RISER DRAWING SHOWING PIPE | | SIZES, LOCATIONS OF SHUTOFF VALVES, WATER HAMMER | | ARRESTORS, MIXING VALVES ETC.- SECTION 107.3.5.1.3 WPB | | AMENDMENTS TO THE FBC. | | | | 6) A3: PROVIDE PLUMBING FIXTURE AND DEVICE SCHEDULES ON | | THE PLAN- SECTION 107.2.1 WPB & SECTION 405.9 FBC P. | | | | 7) A3: INDICATE HOW TEMPERED WATER WILL BE PROVIDED TO | | THE LAVATORY- SECTION 416.5 FBC P. | | | | 8) A1 & A3: PROVIDE THE SCOPE OF WORK FOR THE REQUIRED | | WATER HEATER- SECTION 607.1 FBC P. CLARIFY IF THE | | APPLIANCE IS EXISTING OR TO BE REPLACED. SHOW THE | | LOCATION AND PROVIDE PLUMBING DETAILS IF APPLICABLE. | | PLEASE NOTE THAT THE DEVELOPED LENGTH OF HOT OR | | TEMPERED WATER PIPING, FROM THE SOURCE OF HOT WATER TO | | THE FIXTURES THAT REQUIRE HOT OR TEMPERED WATER, SHALL | | NOT EXCEED 50 FEET. | | | | 9) A1 & A3: CONCERNING THE REQUIRED DRINKING FOUNTAINS | | PLEASE SEE SECTION 211.1.2 FBC ACC- NO FEWER THAN TWO | | DRINKING FOUNTAINS SHALL BE PROVIDED. ONE DRINKING | | FOUNTAIN SHALL COMPLY WITH SECTIONS 602.1 - 602.6, AND | | ONE SHALL COMPLY WITH 602.7. SECTION 602.7 REQUIRES | | THAT SPOUT OUTLETS FOR STANDING PERSONS SHALL BE 38 | | INCHES MINIMUM AND 43 INCHES MAXIMUM FROM THE FINISHED | | FLOOR. SHOW THE LOCATIONS OF THE FOUNTAIN AND SHOW: | | A) THE CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS FOR | | FORWARD WHEELCHAIR APPROACH- SECTION 602.2. FBC ACC. | | B) KNEE AND TOE CLEARANCES- SECTION 306. | | C) SPOUT HEIGHT AND SPOUT LOCATION- SECTION 602.4 AND | | 602.5. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | CHRISTOPHER L. COLE | | MECHANICAL/PLUMBING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | | 2020-07-01 16:35:39 | TIM HUNT |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
4 |
Status |
P |
Date |
2020-09-28 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2020-09-28 |
Time |
07:33 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2020-09-28 |
Time |
07:33 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
P |
Date |
2020-09-01 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2020-09-01 |
Time |
07:44 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2020-08-10 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2020-08-10 |
Time |
17:32 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2020-08-10 |
Time |
17:32 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2020-07-02 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2020-07-02 |
Time |
12:00 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2020-07-02 |
Time |
12:00 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2020-08-05 |
|
|
Cont ID |
|
Sent By |
awooten |
Date |
2020-08-05 |
Time |
|
Rev Time |
0.00 |
Received By |
awooten |
Date |
2020-08-05 |
Time |
|
Sent To |
|
|
Notes |
|
|