Plan Review Stops For Permit 20060341 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2020-08-25 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-08-25 |
Time |
11:34 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-08-25 |
Time |
07:38 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2020-07-08 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-07-08 |
Time |
10:58 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-07-08 |
Time |
07:26 |
Sent To |
|
|
Notes |
2020-07-08 10:58:42 | PLAN REVIEW - BUILDING | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER BUILDING - PX3169 | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | CODES IN EFFECT: | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | 1ST REVIEW | | | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1) FBC 107.3.5.3 - PROVIDE WIND DESIGN LOADS FOR THE | | GENERATOR PURSUANT TO FBC-R301.2 AND AS REQUIRED BY THE | | GENERATOR PAD ENGINEERING THAT WAS SUBMITTED. | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2020-08-25 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-08-25 |
Time |
11:37 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-08-25 |
Time |
07:38 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2020-07-08 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-07-08 |
Time |
11:00 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-07-08 |
Time |
07:26 |
Sent To |
|
|
Notes |
2020-07-08 11:00:51 | PLAN REVIEW - ELECTRICAL | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER BUILDING - PX3169 | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | CODES IN EFFECT: | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | 1ST REVIEW | | | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. PROVIDE ATS SPECS. |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
P |
Date |
2020-08-25 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-08-25 |
Time |
11:36 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-08-25 |
Time |
07:38 |
Sent To |
|
|
Notes |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
F |
Date |
2020-07-08 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-07-08 |
Time |
10:59 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-07-08 |
Time |
07:26 |
Sent To |
|
|
Notes |
2020-07-08 10:59:59 | PLAN REVIEW - FUEL GAS | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER BUILDING - PX3169 | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | CODES IN EFFECT: | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | 1ST REVIEW | | | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. PROVIDE DETAIL OF GENERATOR GAS COMPONENTS. RISER, | | SHUTOFF, REGULATOR, DRIP LEG AND FLEX CONNECTOR. | | | | 2. PROVIDE APPROPRIATE TABLE FOR 2 PSI P.E. PIPE FROM | | FBC RESIDENTIAL FUEL GAS TABLES. | | | | 3. PROVIDE TOTAL SUPPLY BTU FROM UTILITY. | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2020-08-25 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-08-25 |
Time |
11:39 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-08-24 |
Time |
13:50 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2020-07-08 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-07-08 |
Time |
11:02 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-06-22 |
Time |
14:22 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
N |
Date |
2020-08-25 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-08-25 |
Time |
07:38 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-08-25 |
Time |
07:38 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
N |
Date |
2020-07-08 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-07-08 |
Time |
11:02 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-07-08 |
Time |
07:26 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2020-08-25 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-08-25 |
Time |
11:37 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-08-25 |
Time |
07:38 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2020-07-08 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-07-08 |
Time |
11:01 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-07-08 |
Time |
07:26 |
Sent To |
|
|
Notes |
2020-07-08 11:01:55 | PLAN REVIEW - DIGITAL SIGNATURES AND SEALS | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER BUILDING - PX3169 | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | CODES IN EFFECT: | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | 1ST REVIEW | | | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1) THE ENGINEER'S DIGITAL SIGNATURE IS REQUIRED ON | | ELECTRONICALLY SUBMITTED DRAWINGS. FS 471 & FAC 61G15 | | | | . UPLOAD VIA THE PROJECTDOX PORTAL WITH DIGITAL | | SIGNATURES OF DESIGN PROFESSIONALS AS APPLICABLE; USE | | THE REQUIRED NAMING CONVENTION FOR EACH DOCUMENT. | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2020-08-25 |
|
|
Cont ID |
|
Sent By |
rthermid |
Date |
2020-08-25 |
Time |
|
Rev Time |
0.00 |
Received By |
rthermid |
Date |
2020-08-25 |
Time |
|
Sent To |
I |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2020-06-29 |
|
|
Cont ID |
|
Sent By |
rthermid |
Date |
2020-06-29 |
Time |
|
Rev Time |
|
Received By |
rthermid |
Date |
2020-06-29 |
Time |
|
Sent To |
I |
|
Notes |
2020-06-29 13:25:25 | ZONING PLAN REVIEW | | ________________________________________ | | | | DATE OF REVIEW: 6/29/2020 | | ________________________________________ | | | | REVIEW STATUS: FAILED | | ________________________________________ | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | REVIEW COMMENTS: | | | | 1. PLEASE PROVIDE THE SETBACKS FROM ALL PROPERTY | | LINES. | | ________________________________________ | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | IF THE RESUBMITTAL IS NOT PREPARED BY A DESIGN | | PROFESSIONAL (ARCHITECT OR ENGINEER), AND THE PAGES ARE | | 11X17 OR SMALLER, YOU MAY RESUBMIT, ALONG WITH A | | COMPLETED RESUBMITTAL FORM, VIA EMAIL TO | | [email protected]. THE EMAIL SHOULD INCLUDE THE PERMIT | | NUMBER AND "RESUBMITTAL" IN THE SUBJECT LINE. THE | | RESUBMITTAL FORM CAN BE FOUND AT THIS WEBSITE: | | | | HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B | | UILDING-PERMIT-FORMS | | | | IF THE FORM IS TEMPORARILY UNAVAILABLE, PLEASE REQUEST | | THAT IT BE SENT TO YOU BY EMAILING [email protected] | | ________________________________________ | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | RAFAELA THERMIDOR, ASSOCIATE PLANNER | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | 401 CLEMATIS STREET - P.O. BOX 3147 | | WEST PALM BEACH, FLORIDA 33402 | | | | P: 561.822.1443 | | TTY: 800.955.8771 | | E: [email protected] | | | | W: WPB.ORG | | |
|
|