Plan Review Stops For Permit 20060298 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2021-02-26 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-02-26 |
Time |
14:20 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-02-26 |
Time |
14:20 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2020-07-09 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-07-09 |
Time |
14:02 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-07-09 |
Time |
14:02 |
Sent To |
|
|
Notes |
2020-07-09 14:03:23 | GENERATOR | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected]. | | CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1 | | AMENDMENTS | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | 1) SLAB ENGINEERING = SIGNED AND SEALED DRAWINGS NEED | | TO BE DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER | | OR ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW - OR | | - IF YOUR ENGINEER DOES NOT HAVE A ELECTRONIC OR | | DIGITAL SIGNATURE - PLEASE DROP OFF (CITY HALL DROP | | BOX) THE ORIGINAL SIGNED AND SEALED DOCUMENT ALONG WITH | | A "PLAN REVIEW REQUEST FORM" EXPLAINING THE REASON FOR | | SUBMITTING THE DOCUMENT OR DRAWINGS. PLAN REVIEW | | REQUEST FORM CAN BE OBTAINED BY E MAILING [email protected] | | AND ASKING FOR THE FORM. | | 2) SLAB ENGINEERING PROVIDED REQUIRES A SEPARATE SIGNED | | AND SEALED ENGINEERING SHOWING THE SITE SPECIFIC WIND | | DESIGN PRESSURES - SEE NOTE NUMBER 2 ON THE PROVIDED | | ENGINEERING. | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2021-02-19 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-02-19 |
Time |
10:54 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-02-19 |
Time |
10:15 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2020-07-10 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-07-10 |
Time |
11:33 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-07-10 |
Time |
10:14 |
Sent To |
|
|
Notes |
2020-07-10 11:34:24 | PLAN REVIEW - ELECTRIC | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER BUILDING - PX3169 | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | CODES IN EFFECT: | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | 1ST REVIEW | | | | RESULTS: DENIED | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | BELOW. | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. PROVIDE ATS SPECIFICATIONS. | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | 107.2.5. | | | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
P |
Date |
2021-02-19 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-02-19 |
Time |
10:57 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-02-19 |
Time |
10:15 |
Sent To |
|
|
Notes |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
F |
Date |
2020-07-10 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-07-10 |
Time |
11:29 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-07-10 |
Time |
10:14 |
Sent To |
|
|
Notes |
2020-07-10 11:33:12 | PLAN REVIEW - FUEL GAS GENERATOR | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER BUILDING - PX3169 | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | CODES IN EFFECT: | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | 1ST REVIEW | | | | RESULTS: DENIED | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | BELOW. | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1) GAS ISOMETRIC DRAWING: | | A) THE DRAWING IS INCOMPLETE AND MUST BE MODIFIED TO | | SHOW THE ENTIRE SYSTEM INCLUDING ALL BRANCH PIPES FROM | | THE METER TO THE MOST REMOTE OUTLET. THE BTUH LOAD OF | | EACH APPLIANCE AND THE LOCATIONS OF REGULATORS SHALL BE | | INDICATED ON THE DRAWING- SECTIONS G2412.3 & G2412.4 | | FBC RES. | | B) PROVIDE THE TOTAL DEVELOPED LENGTH OF THE SYSTEM | | FROM THE METER TO THE MOST REMOTE OUTLET, AND BRANCH | | LENGTH SIZES- SECTIONS G2413.4.1, G2413.4.2 & | | G2413.4.3. | | B) PROVIDE DELIVERY PRESSURE TO THE GENERATOR FROM THE | | OUTLET OF THE REGULATOR- SECTION G2421.1 | | C) CORRECT THE BTUH LOAD OF THE GENERATOR. THE | | SUBMITTED SPECS INDICATE 327,000 BTUH FULL LOAD- | | G2413.2 FBC RES. | | | | | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2021-04-06 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2021-04-06 |
Time |
09:16 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2021-02-05 |
Time |
23:35 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2020-07-21 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2020-07-21 |
Time |
08:21 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2020-06-22 |
Time |
15:25 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
N |
Date |
2021-02-19 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-02-19 |
Time |
10:15 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-02-19 |
Time |
10:15 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
N |
Date |
2020-07-10 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-07-10 |
Time |
11:34 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-07-10 |
Time |
10:14 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2021-04-06 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-02-26 |
Time |
14:21 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2021-02-26 |
Time |
14:21 |
Sent To |
|
|
Notes |
2021-04-06 09:19:06 | APPROVED SIGNATURE | | | 2021-02-26 14:22:05 | SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE | | DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR | | ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW. | | DRAWINGS DO NOT SHOW IN "ADOBE READER" AS | | DIGITALLY/ELECTRONICALLY SIGNED. - OR - IF YOUR | | ARCHITECT OR ENGINEER DOES NOT HAVE AN ELECTRONIC OR | | DIGITAL SIGNATURE ? YOU CAN MAIL IN OR DROP OFF THE | | ORIGINAL SIGNED AND SEALED DRAWINGS/DOCUMENTS TO THE | | FRONT DESK IN THE BUILDING DEPT. AT THE CITY HALL |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2020-07-09 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-07-09 |
Time |
14:03 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-07-09 |
Time |
14:03 |
Sent To |
|
|
Notes |
2020-07-09 14:03:58 | SEE BUILDING PLAN REVIEW |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2021-04-05 |
|
|
Cont ID |
|
Sent By |
kalexand |
Date |
2021-04-05 |
Time |
|
Rev Time |
0.00 |
Received By |
rthermid |
Date |
2021-04-05 |
Time |
|
Sent To |
I |
|
Notes |
2021-04-05 12:31:29 | VARIANCE #3389 - APPROVED | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
|
|
|
Cont ID |
|
Sent By |
kalexand |
Date |
2020-07-20 |
Time |
|
Rev Time |
|
Received By |
|
Date |
2020-07-20 |
Time |
|
Sent To |
I |
|
Notes |
2020-07-20 14:12:54 | ZONING PLAN REVIEW | | ________________________________________ | | | | DATE OF REVIEW: 7/20/20 | | ________________________________________ | | | | REVIEW STATUS: FAILED | | ________________________________________ | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | REVIEW COMMENTS: | | | | 1. AS THE FRONTAGE ALONG S. OLIVE IS THE NARROWEST, IT | | IS LEGALLY CONSIDERED THE FRONT SETBACK. A GENERATOR | | MAY NOT ENCROACH INTO THE REQUIRED 25FT FRONT SETBACK. | | ________________________________________ | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | IF THE RESUBMITTAL IS NOT PREPARED BY A DESIGN | | PROFESSIONAL (ARCHITECT OR ENGINEER), AND THE PAGES ARE | | 11X17 OR SMALLER, YOU MAY RESUBMIT, ALONG WITH A | | COMPLETED RESUBMITTAL FORM, VIA EMAIL TO | | [email protected]. THE EMAIL SHOULD INCLUDE THE PERMIT | | NUMBER AND "RESUBMITTAL" IN THE SUBJECT LINE. THE | | RESUBMITTAL FORM CAN BE FOUND AT THIS WEBSITE: | | | | HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B | | UILDING-PERMIT-FORMS | | | | IF THE FORM IS TEMPORARILY UNAVAILABLE, PLEASE REQUEST | | THAT IT BE SENT TO YOU BY EMAILING [email protected] | | ________________________________________ | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | KIZZI ALEXANDRE, ASSOCIATE PLANNER | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | 401 CLEMATIS STREET - P.O. BOX 3147 | | WEST PALM BEACH, FLORIDA 33402 | | | | P: 561.822.1442 | | TTY: 800.955.8771 | | E: [email protected] | | | | W: WPB.ORG | | |
|
|