Plan Review Stops For Permit 20060181 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2020-08-19 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2020-08-19 |
Time |
07:46 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2020-08-19 |
Time |
07:46 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2020-07-22 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2020-07-22 |
Time |
13:45 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2020-07-22 |
Time |
13:45 |
Sent To |
|
|
Notes |
2020-07-22 13:45:24 | PLAN | | REVIEW COMMENTS | | | | 2ND REVIEW: FBC SIXTH EDITION (2017) | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY BUILDING | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) THE GENERATOR PAD ENGINEERING IS NOT THE CORRECT ONE | | FOR THE GENERAC MODEL G0007042-2, 22 KW GENERATOR THE | | SPECIFICATIONS WERE SUBMITTED FOR. FBC 107.2.1 | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2020-06-24 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2020-06-24 |
Time |
15:59 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2020-06-24 |
Time |
15:59 |
Sent To |
|
|
Notes |
2020-06-24 16:02:35 | PLAN | | REVIEW COMMENTS | | | | 1ST REVIEW: FBC SIXTH EDITION (2017) | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY BUILDING | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) FBC 107.3.5.3 - PROVIDE WIND DESIGN LOADS FOR THE | | GENERATOR PURSUANT TO FBC-R301.2 AND AS REQUIRED BY THE | | GENERATOR PAD ENGINEERING THAT WAS SUBMITTED. | | | | 2) THE ENGINEER'S DIGITAL SIGNATURE IS REQUIRED ON | | ELECTRONICALLY SUBMITTED DRAWINGS. FS 471 & FAC 61G15 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2020-06-25 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-06-25 |
Time |
14:11 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-06-25 |
Time |
13:39 |
Sent To |
|
|
Notes |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
P |
Date |
2020-06-25 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-06-25 |
Time |
14:14 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-06-25 |
Time |
13:39 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2020-08-19 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2020-08-19 |
Time |
07:47 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2020-08-04 |
Time |
13:51 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2020-07-22 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2020-07-22 |
Time |
13:45 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2020-07-06 |
Time |
11:25 |
Sent To |
|
|
Notes |
2020-07-16 12:31:42 | 07/16/2020 RESUBMITTAL UPLOADED TO PROJECT DOX. DRAWING | | WITH ENGINEER'S ORIGINAL SIGNATURE SENT TO "STORAGE". | | JG. | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2020-07-02 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2020-07-02 |
Time |
14:26 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2020-06-11 |
Time |
16:42 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
N |
Date |
2020-06-25 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-06-25 |
Time |
14:11 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-06-25 |
Time |
13:39 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
5 |
Status |
P |
Date |
2020-08-19 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2020-08-19 |
Time |
17:43 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2020-08-19 |
Time |
17:41 |
Sent To |
|
|
Notes |
2020-08-19 17:43:22 | 08/19/2020 ENGINEER DRAWING MATCHES ONE UPLOADED TO | | PROJECTDOX. DRAWING WITH EMBOSSED SEAL AND ORIGINAL | | SIGNATURE SENT TO STORAGE. JG. |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
4 |
Status |
P |
Date |
2020-08-14 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2020-08-14 |
Time |
14:36 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2020-08-14 |
Time |
14:35 |
Sent To |
|
|
Notes |
2020-08-14 14:38:21 | 08/14/2020 | | CONCRETE PAD ENGINEERING WITH ORIGINAL SEAL/SIGNATURE | | MATCHES ONE UPLOADED TO PROJECTDOX. JG. |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
F |
Date |
2020-08-04 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2020-08-04 |
Time |
10:31 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2020-08-04 |
Time |
10:30 |
Sent To |
|
|
Notes |
2020-08-04 10:31:34 | NOTE: | | THIS REVIEW IS ONLY FOR THE SIGNATURE REVIEW. | | CONTRACTOR NEEDS TO UPLOAD TO PROJECTDOX THE | | INFORMATION REQUESTED BY THE PLANS EXAMINER FOR | | BUILDING. | | | | 1-ENGINEER WHO SIGNED AND SEALED THE CONCRETE PAD | | ENGINEERING IS NOT THE SAME ENGINEER WHO SIGNED/SEALED | | THE ORIGINAL ENGINEERING SUBMITTED. SEC. 107.3 CITY | | AMENDMENTS. | | THERE ARE THERE TWO OPTIONS TO ADDRESS THIS ISSUE: | | (1)SUBMIT ENGINEERING WITH ORIGINAL SEAL/SIGNATURE OF | | THE ENGINEER WHO SIGNED THE ORIGINAL SUBMITTAL. OR | | (2) UPLOAD TO PROJECTDOX NEW DOCUMENT SIGNED/SEALED BY | | THE NEW ENGINEER FOR BUILDING REVIEW. | | NOTE: IN ORDER TO EXPEDITE THE REVIEW PROCESS, IT IS | | PREFERABLE TO DOWNLOAD THE NEW ENGINEERING WITH A | | DIGITAL SIGNATURE. OTHERWISE, HARD COPY WITH ORIGINAL | | SEAL/SIGNATURE IS REQUIRED. WE CAN USE THE ONE | | SUBMITTED NOW IF IT MATCHES THE ONE THAT WAS DOWNLOADED | | TO PROJECTDOX. | | | | 2- THE CONCRETE PAD ENGINEERING SUBMITTED DOESN'T MATCH | | THE ORIGINAL ENGINEERING THAT WAS UPLOADED TO | | PROJECTDOX. SEC. 107.3 CITY AMENDMENTS. | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | QUESTIONS REGARDING THESE COMMENTS, | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2020-07-16 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2020-07-16 |
Time |
11:27 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2020-07-16 |
Time |
11:26 |
Sent To |
|
|
Notes |
2020-07-16 11:27:47 | CONVERTED TO DIGITAL. | | DRAWINGS/CALCULATIONS WITH ENGINEER'S ORIGINAL | | SEAL/SIGNATURE IN CITY'S FILE. JG | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2020-06-24 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2020-06-24 |
Time |
15:59 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2020-06-24 |
Time |
15:59 |
Sent To |
|
|
Notes |
2020-06-24 16:03:11 | THE ENGINEER'S DIGITAL SIGNATURE IS REQUIRED ON | | ELECTRONICALLY SUBMITTED DRAWINGS. FS 471 & FAC 61G15 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
|
|
|
Cont ID |
|
Sent By |
kalexand |
Date |
2020-07-02 |
Time |
|
Rev Time |
|
Received By |
|
Date |
2020-07-02 |
Time |
|
Sent To |
I |
|
Notes |
|
|