Plan Review Stops For Permit 20060169 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2020-10-20 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-10-20 |
Time |
09:44 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-10-20 |
Time |
07:43 |
Sent To |
|
|
Notes |
2020-10-20 09:45:15 | NO NOTES |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2020-10-05 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-10-02 |
Time |
14:50 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-10-02 |
Time |
14:45 |
Sent To |
|
|
Notes |
2020-10-05 08:21:50 | PLAN REVIEW GENERATOR / BUILDING | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER BUILDING - PX3169 | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | CODES IN EFFECT: | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | 1ST REVIEW | | | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. PROVIDE GENERATOR PAD DESIGN FOR 27KW GENERATOR. | | NOTE: 27KW GENERATOR WEIGHT IS 426 LBS. SEE PAGE 6 OF | | 11 OF GENERATOR SPECS. | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | 107.2.5. | | | | 2. PROVIDE SITE SPECIFIC WIND DESIGN LOADS OF GENERATOR | | PER R301 OR ASCE 7-10. | | R301.2.1 WIND DESIGN CRITERIA. | | BUILDINGS AND PORTIONS THEREOF SHALL BE CONSTRUCTED IN | | ACCORDANCE WITH THE WIND PROVISIONS OF THIS CODE USING | | THE BASIC WIND SPEED IN TABLE R301.2(1) AS DETERMINED | | FROM FIGURE R301.2(4). | | | | | | 2. DESIGNER TO SIGN DESIGN. | | FBC 107.2.1 ALL INFORMATION, DRAWINGS, SPECIFICATIONS | | AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE | | OF THE PERSON RESPONSIBLE FOR THE DESIGN. (SEE ALSO | | SECTION 107.3.5), CHPT. 471, F.S. & 61G15 AND CHPT. | | 481, F.S. & 61G1. | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2020-07-07 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-07-07 |
Time |
15:41 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-07-07 |
Time |
15:13 |
Sent To |
|
|
Notes |
2020-07-07 15:42:30 | PLAN REVIEW - BUILDING | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER BUILDING - PX3169 | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | CODES IN EFFECT: | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | 1ST REVIEW | | | | RESULTS: DENIED | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | BELOW. | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1) FBC 107.3.5.3 - PROVIDE WIND DESIGN LOADS FOR THE | | GENERATOR PURSUANT TO FBC-R301.2 AND AS REQUIRED BY THE | | GENERATOR PAD ENGINEERING THAT WAS SUBMITTED. | | | | 2) THE ENGINEER'S DIGITAL SIGNATURE IS REQUIRED ON | | ELECTRONICALLY SUBMITTED DRAWINGS. FS 471 & FAC 61G15 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2020-09-24 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2020-09-24 |
Time |
17:04 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2020-09-24 |
Time |
17:04 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2020-07-07 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-07-07 |
Time |
15:43 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-07-07 |
Time |
15:13 |
Sent To |
|
|
Notes |
2020-07-07 15:44:26 | PLAN REVIEW - ELECTRICAL | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER BUILDING - PX3169 | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | CODES IN EFFECT: | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | 1ST REVIEW | | | | RESULTS: DENIED | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | BELOW. | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. PROVIDE ATS SPECS. |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
4 |
Status |
P |
Date |
2020-10-20 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-10-20 |
Time |
08:00 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-10-20 |
Time |
07:47 |
Sent To |
|
|
Notes |
2020-10-20 08:02:47 | GAS CONTRACTOR: DIG IT UNLIMITED SHALL SUBMIT GAS | | SUB-PERMIT. CT |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
3 |
Status |
F |
Date |
2020-10-05 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2020-10-05 |
Time |
09:06 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2020-10-05 |
Time |
09:06 |
Sent To |
|
|
Notes |
2020-10-05 09:08:14 | I DO NOT SEE THE CHANGE OF CONTRACTOR FORM FOR THE GAS | | INSTALLATION CONTRACTOR. | | PLEASE SEE BUILDING REVIEWERS COMMENTS ON THE GENERATOR | | PAD. | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | | | | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
F |
Date |
2020-09-22 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2020-09-22 |
Time |
15:42 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2020-09-22 |
Time |
15:41 |
Sent To |
|
|
Notes |
2020-09-22 15:42:31 | 2ND REVIEW FBC-2017 MECHANICAL | | PERMIT-20060169 | | | | CODES IN EFFECT: | | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | EDITION 2017 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2017 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) THE APPLICATION FOR PERMIT IS FOR A 27KW NATURAL GAS | | GENERATOR. THE GENERATOR PAD SPEC SHEET IS FOR A 22KW | | GENERATOR. PLEASE PROVIDE THE DIGITALLY SIGNED AND | | SEALED SPEC SHEETS FOR THE 27 KW GENERATOR. FBC FS | | 107.2.1 | | | | 2) THE GAS SUB PERMIT HAS BPM GAS SYSTEMS AS THE | | CONTRACTOR, THE GAS ISOMETRIC HAS DIG IT UNLIMITED. IF | | THE CONTRACTOR HAS CHANGED PLEASE SUBMIT A CHANGE OF | | CONTRACTOR FORM AND FILL OUT A NEW GAS SUB PERMIT. FBC | | FS 107.2.1 | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD | | SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER | | SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN | | THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS | | PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS | | PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR | | UPDATED. | | | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
F |
Date |
2020-07-07 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-07-07 |
Time |
15:42 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-07-07 |
Time |
15:13 |
Sent To |
|
|
Notes |
2020-07-07 15:41:13 | PLAN REVIEW - FUEL GAS | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER BUILDING - PX3169 | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | CODES IN EFFECT: | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | 1ST REVIEW | | | | RESULTS: DENIED | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | BELOW. | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. PROVIDE DETAIL OF GENERATOR GAS COMPONENTS. RISER, | | SHUTOFF, REGULATOR, DRIP LEG AND FLEX CONNECTOR. | | | | 2. PROVIDE APPROPRIATE TABLE FOR 2 PSI P.E. PIPE FROM | | FBC RESIDENTIAL FUEL GAS TABLES. | | | | 3. PROVIDE SPECS. FOR 2 PSI REGULATOR RATED FOR | | EXTERIOR INSTALLATION. | | | | 4. PROVIDE SPECS. FOR FLEX CONNECTOR. | | | | 5. PROVIDE TOTAL SUPPLY BTU FROM UTILITY. | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2020-10-20 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-10-20 |
Time |
10:00 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-10-14 |
Time |
10:48 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2020-10-05 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2020-10-05 |
Time |
09:09 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2020-10-02 |
Time |
16:54 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2020-10-02 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-10-02 |
Time |
14:50 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-09-17 |
Time |
07:22 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2020-07-07 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-07-07 |
Time |
15:45 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-06-22 |
Time |
14:33 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
N |
Date |
2020-10-20 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-10-20 |
Time |
08:02 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-10-20 |
Time |
07:43 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
N |
Date |
2020-10-05 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2020-10-05 |
Time |
09:09 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2020-10-05 |
Time |
09:09 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
N |
Date |
2020-09-22 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2020-09-22 |
Time |
15:42 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2020-09-22 |
Time |
15:42 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
N |
Date |
2020-07-07 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-07-07 |
Time |
15:40 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-07-07 |
Time |
15:13 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
P |
Date |
2020-10-02 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-10-02 |
Time |
14:49 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-10-02 |
Time |
14:48 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2020-09-22 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2020-09-22 |
Time |
15:43 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2020-09-22 |
Time |
15:43 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2020-07-07 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-07-07 |
Time |
15:44 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-07-07 |
Time |
15:13 |
Sent To |
|
|
Notes |
2020-07-07 15:45:21 | PLAN REVIEW - DIGITAL SIGNATURES AND SEALS | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER BUILDING - PX3169 | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | CODES IN EFFECT: | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | 1ST REVIEW | | | | RESULTS: DENIED | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | BELOW. | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1) THE ENGINEER'S DIGITAL SIGNATURE IS REQUIRED ON | | ELECTRONICALLY SUBMITTED DRAWINGS. FS 471 & FAC 61G15 | | | | . UPLOAD VIA THE PROJECTDOX PORTAL WITH DIGITAL | | SIGNATURES OF DESIGN PROFESSIONALS AS APPLICABLE; USE | | THE REQUIRED NAMING CONVENTION FOR EACH DOCUMENT. | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2020-06-29 |
|
|
Cont ID |
|
Sent By |
rthermid |
Date |
2020-06-29 |
Time |
|
Rev Time |
|
Received By |
rthermid |
Date |
2020-06-29 |
Time |
|
Sent To |
I |
|
Notes |
|
|