Plan Review Stops For Permit 20060162 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2020-10-13 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-10-13 |
Time |
14:19 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-10-13 |
Time |
08:00 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2020-07-07 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-07-07 |
Time |
14:36 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-07-07 |
Time |
14:09 |
Sent To |
|
|
Notes |
2020-07-07 14:36:33 | PLAN REVIEW - BUILDING | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER BUILDING - PX3169 | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | CODES IN EFFECT: | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | 1ST REVIEW | | | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1) FBC 107.3.5.3 - PROVIDE WIND DESIGN LOADS FOR THE | | GENERATOR PURSUANT TO FBC-R301.2 AND AS REQUIRED BY THE | | GENERATOR PAD ENGINEERING THAT WAS SUBMITTED. | | | | 2) THE ENGINEER'S DIGITAL SIGNATURE IS REQUIRED ON | | ELECTRONICALLY SUBMITTED DRAWINGS. FS 471 & FAC 61G15 | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2020-10-13 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-10-13 |
Time |
08:35 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-10-13 |
Time |
08:00 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2020-07-07 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-07-07 |
Time |
14:35 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-07-07 |
Time |
14:09 |
Sent To |
|
|
Notes |
2020-07-07 15:39:32 | PLAN REVIEW - ELECTRICAL | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER BUILDING - PX3169 | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | CODES IN EFFECT: | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | 1ST REVIEW | | | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. PROVIDE ATS SPECS. | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
N |
Date |
2020-09-23 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2020-09-23 |
Time |
14:54 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2020-09-23 |
Time |
14:54 |
Sent To |
|
|
Notes |
2020-09-23 14:55:38 | PROVISO: SEPARATE PERMIT AND PLANS REQUIRED PRIOR TO | | COMMENCEMENT OF GAS WORK | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
F |
Date |
2020-07-07 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-07-07 |
Time |
14:37 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-07-07 |
Time |
14:09 |
Sent To |
|
|
Notes |
2020-07-07 14:42:39 | PLAN REVIEW - FUEL GAS | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER BUILDING - PX3169 | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | CODES IN EFFECT: | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | 1ST REVIEW | | | | RESULTS: DENIED | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | BELOW. | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | OUR RECORDS INDICATE AN EXISTING NG SERVICE AT THE | | PROPERTY. PROVIDE A CODE COMPLIANT GAS RISER DIAGRAHM. | | | | 1. PROVIDE DETAIL OF GENERATOR GAS COMPONENTS. RISER, | | SHUTOFF, REGULATOR, DRIP LEG AND FLEX CONNECTOR. | | | | 2. PROVIDE APPROPRIATE TABLE FOR 2 PSI P.E. PIPE FROM | | FBC RESIDENTIAL FUEL GAS TABLES. | | | | 3. PROVIDE TOTAL SUPPLY BTU FROM UTILITY. | | | | 4. PROVIDE TOTAL GAS LOADS. INCLUDE EXISTING GAS | | APPLIANCES. | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2020-10-13 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-10-13 |
Time |
14:19 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-09-29 |
Time |
14:38 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2020-07-07 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-07-07 |
Time |
14:42 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-06-22 |
Time |
14:32 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
N |
Date |
2020-07-07 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-07-07 |
Time |
14:34 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-07-07 |
Time |
14:09 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2020-10-13 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-10-13 |
Time |
08:36 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-10-13 |
Time |
08:00 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2020-07-07 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-07-07 |
Time |
14:37 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-07-07 |
Time |
14:10 |
Sent To |
|
|
Notes |
2020-07-07 14:37:32 | PLAN REVIEW - DIGITAL SIGNATURES AND SEALS | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER BUILDING - PX3169 | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | CODES IN EFFECT: | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | 1ST REVIEW | | | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1) THE ENGINEER'S DIGITAL SIGNATURE IS REQUIRED ON | | ELECTRONICALLY SUBMITTED DRAWINGS. FS 471 & FAC 61G15 | | | | . UPLOAD VIA THE PROJECTDOX PORTAL WITH DIGITAL | | SIGNATURES OF DESIGN PROFESSIONALS AS APPLICABLE; USE | | THE REQUIRED NAMING CONVENTION FOR EACH DOCUMENT. | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2020-06-29 |
|
|
Cont ID |
|
Sent By |
rthermid |
Date |
2020-06-29 |
Time |
|
Rev Time |
|
Received By |
rthermid |
Date |
2020-06-29 |
Time |
|
Sent To |
I |
|
Notes |
|
|