Plan Review Details - Permit 20060131
Plan Review Stops For Permit 20060131
Review Stop AD ADDRESSING
Rev No 1 Status P Date 2020-06-03 Cont ID  
Sent By cpuell Date 2020-06-03 Time 08:55 Rev Time 0.00
Received By cpuell Date 2020-06-03 Time 08:55 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2020-09-16 Cont ID  
Sent By rmcphers Date 2020-09-16 Time 08:44 Rev Time 0.00
Received By rmcphers Date 2020-09-16 Time 08:44 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status F Date 2020-08-10 Cont ID  
Sent By rmcphers Date 2020-08-10 Time 13:30 Rev Time 0.00
Received By rmcphers Date 2020-08-10 Time 12:31 Sent To  
Notes
2020-08-10 12:39:36WINDOWS/DOORS/SHUTTERS
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected].
 CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1
 AMENDMENTS
  
 CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107
 1) THE 10 STORY BUILDING WOULD USE A MEAN ROOF HEIGHT
 OF 120 PER THE WIND DESIGN PRESSURE CHART PROVIDED.
 2) THE SLIDING GLASS DOOR SHOWN IN WIND ZONE 5 DOES NOT
 MEET THE REQUIRED WIND PRESSURES OF (-100.9) PER THE
 CHART PROVIDED. (CANNOT USE A SHUTTER TO MAKE UP FOR
 THE REQUIRED PRESSURES ON THE DOOR)
 3) THE SHUTTER NUMBER 13 DOES NOT MEET THE REQUIRED
 WIND DESIGN PRESSURES (THERE IS NO ON CENTER SPACING
 FOR 8 FOOT SPAN, (-100.9), USING (G) AT THE TOP).
 4) SHUTTER NUMBER 1 = THE ON CENTER SPACING FOR THE (G)
 TOP SHOWN ON THE SHUTTER ATTACHMENT FORM IS INCORRECT
 (SHOULD BE 8 INCHES ON CENTER)
 5) PLEASE SHOW THE ENTIRE BUILDING LENGTH AND WIDTH -
 NEEDED TO DETERMINE WIND ZONES 4 AND 5.
 6) PLEASE UPDATE YOUR WINDOW SCHEDULE - YOU SHOW THE
 BUILDING LESS THAN 70 FEET HIGH. WIND DESIGN PRESSURES
 ARE BASED ON THE BUILDING ROOF HEIGHT (THE BUILDING
 APPEARS TO BE 10 STORIES WHICH WOULD BE APPROXAMETLY
 100 FEET HIGH).
 7) THE WIND DESIGN PRESSURE CHART NEEDS TO BE SIGNED
 ELECTRONICALLY BY THE ENGINEER - SEE FYI BELOW.
  
 THE BEST WAY TO REACH ME IS BY E MAIL (PLEASE E MAIL
 QUESTIONS TO [email protected])
  
 FYI = SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO
 BE DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR
 ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW.
 DRAWINGS DO NOT SHOW IN "ADOBE READER" AS
 DIGITALLY/ELECTRONICALLY SIGNED. - OR - IF YOUR
 ENGINEER DOES NOT HAVE AN ELECTRONIC OR DIGITAL
 SIGNATURE - PLEASE DROP OFF (CITY HALL DROP BOX) THE
 ORIGINAL SIGNED AND SEALED DRAWINGS/DOCUMENTS ALONG
 WITH A "PLAN REVIEW REQUEST FORM" EXPLAINING THE REASON
 FOR SUBMITTING THE DOCUMENT OR DRAWINGS. PLAN REVIEW
 REQUEST FORM CAN BE OBTAINED BY E MAILING [email protected]
 AND ASKING FOR THE FORM. (AT THIS TIME DROP BOX ITEMS
 MAY TAKE 2 TO 3 WEEKS TO PROCESS, TO SEND TO PLAN
 REVIEW - DUE TO LIMITED STAFF INSIDE THE BUILDING
 DEPT.)

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2020-07-17 Cont ID  
Sent By rmcphers Date 2020-07-17 Time 13:43 Rev Time 0.00
Received By rmcphers Date 2020-07-17 Time 13:43 Sent To  
Notes
2020-07-17 13:54:24WINDOWS/DOORS/SHUTTERS
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected].
 CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1
 AMENDMENTS
  
 CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107
 1) BUILDING APPEARS TO BE OVER 60 FEET HIGH - THE WIND
 DESIGN PRESSURES PROVIDED ARE FOR A BUILDING LESSTHAN
 60 FEET HIGH - PLEASE PROVIDE THE CORRECT SIGNED AND
 SEALED WIND DESIGN PRESSURES FROM AN ARCHITECT OR
 ENGINEER FOR THIS BUILDING FBC 1609.
 2) PLEASE PROVIDE A FLOOR PLAN SHOWING THE LOCATION ON
 THE UNIT WITHIN THE BUILDING - NEEDED TO DETERMINE THE
 WIND ZONES 4 OR 5.
 3) IF THE UNIT IS AN END UNIT PLEASE SHOW THE DISTANCE
 FROM THE CORNER OF THE BUILDING TO THE EDGE OF THE
 CORNER WINDOWS OR DOORS - NEEDED TO DETERMINE IF IN
 WIND ZONE 4 OR 5.
 4) PLEASE SHOW THE ENTIRE BUILDING LENGTH AND WIDTH -
 NEEDED TO DETERMINE WIND ZONES 4 AND 5.
 5) PLEASE UPDATE YOUR WINDOW SCHEDULE - YOU SHOW THE
 BUILDING LESSTHAN 55 FEET HIGH. WIND DESIGN PRESSURES
 ARE BASED ON THE BUILDING ROOF HEIGHT (THE BUILDING
 APPEARS TO BE 10 STORIES).
  
 FYI = SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO
 BE DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR
 ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW.
 DRAWINGS DO NOT SHOW IN "ADOBE READER" AS
 DIGITALLY/ELECTRONICALLY SIGNED. - OR - IF YOUR
 ENGINEER DOES NOT HAVE AN ELECTRONIC OR DIGITAL
 SIGNATURE - PLEASE DROP OFF (CITY HALL DROP BOX) THE
 ORIGINAL SIGNED AND SEALED DRAWINGS/DOCUMENTS ALONG
 WITH A "PLAN REVIEW REQUEST FORM" EXPLAINING THE REASON
 FOR SUBMITTING THE DOCUMENT OR DRAWINGS. PLAN REVIEW
 REQUEST FORM CAN BE OBTAINED BY E MAILING [email protected]
 AND ASKING FOR THE FORM. (AT THIS TIME DROP BOX ITEMS
 MAY TAKE 2 TO 3 WEEKS TO PROCESS, TO SEND TO PLAN
 REVIEW - DUE TO LIMITED STAFF INSIDE THE BUILDING
 DEPT.)
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2020-07-02 Cont ID  
Sent By rmcphers Date 2020-07-02 Time 08:02 Rev Time 0.00
Received By rmcphers Date 2020-07-02 Time 08:02 Sent To  
Notes
2020-07-02 08:02:21WINDOWS/DOORS/SHUTTERS
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected].
  
 CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107
 1) PLEASE SHOW ON THE FLOOR PLAN THE WINDOW, DOOR AND
 SHUTTER LOCATIONS (WHAT GOES WHERE) AND SIZES (WIDTH
 AND HEIGHT).
 2) PLEASE SHOW THE DISTANCE FROM THE CORNER OF THE
 BUILDING TO THE EDGE OF THE WINDOWS TO DETERMINE IF IN
 WIND ZONE 4 OR 5.
 3) FBC R 301, COMPLETE THE FORM PROVIDED AT THE FRONT
 COUNTER "SCHEDULE FOR INSTALLATION OF OPENING
 PROTECTIVE DEVICES OR ASSEMBLIES" OR PROVIDE ALL
 INFORMATION REQUIRED IN ANOTHER FORMAT (SUCH AS EXCEL
 SPREADSHEET). WHEN COMPLETING THE INSTALLATION
 SCHEDULE, PLEASE NOTE FACTORS APPLY DEPENDING ON
 SUBSTRATE, EDGE DISTANCE AND FASTENER. FOR FASTENER, IF
 USING TAPCON, BE SPECIFIC AS TO WHICH TAPCON (TAPCON
 W/ADVANCED THREADFORM TECHNOLOGY REQUIRES A .9 FACTOR).
 FORMS CAN BE PROVIDED BY EMAILING AND ASKING FOR
 "SCHEDULE FOR INSTALLATION OF OPENING PROTECTIVE
 DEVICES OR ASSEMBLIES" AT [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-06-25 Cont ID  
Sent By rmcphers Date 2020-06-25 Time 12:43 Rev Time 0.00
Received By rmcphers Date 2020-06-25 Time 12:33 Sent To  
Notes
2020-06-25 12:43:14WINDOWS/DOORS/SHUTTERS
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected].
  
 CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107
 1) PLEASE SHOW ON THE FLOOR PLAN THE WINDOW, DOOR AND
 SHUTTER LOCATIONS (WHAT GOES WHERE) AND SIZES (WIDTH
 AND HEIGHT).
 2) PLEASE SHOW THE DISTANCE FROM THE CORNER OF THE
 BUILDING TO THE EDGE OF THE WINDOWS TO DETERMINE IF IN
 WIND ZONE 4 OR 5.
 3) FBC R 301, COMPLETE THE FORM PROVIDED AT THE FRONT
 COUNTER "SCHEDULE FOR INSTALLATION OF OPENING
 PROTECTIVE DEVICES OR ASSEMBLIES" OR PROVIDE ALL
 INFORMATION REQUIRED IN ANOTHER FORMAT (SUCH AS EXCEL
 SPREADSHEET). WHEN COMPLETING THE INSTALLATION
 SCHEDULE, PLEASE NOTE FACTORS APPLY DEPENDING ON
 SUBSTRATE, EDGE DISTANCE AND FASTENER. FOR FASTENER, IF
 USING TAPCON, BE SPECIFIC AS TO WHICH TAPCON (TAPCON
 W/ADVANCED THREADFORM TECHNOLOGY REQUIRES A .9 FACTOR).
 FORMS CAN BE PROVIDED BY EMAILING AND ASKING FOR
 "SCHEDULE FOR INSTALLATION OF OPENING PROTECTIVE
 DEVICES OR ASSEMBLIES" AT [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2020-09-16 Cont ID  
Sent By rmcphers Date 2020-09-16 Time 08:44 Rev Time 0.00
Received By rmcphers Date 2020-09-14 Time 09:28 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2020-08-10 Cont ID  
Sent By rmcphers Date 2020-08-10 Time 13:31 Rev Time 0.00
Received By rmcphers Date 2020-08-07 Time 10:12 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2020-07-17 Cont ID  
Sent By rmcphers Date 2020-07-17 Time 14:08 Rev Time 0.00
Received By rmcphers Date 2020-07-13 Time 11:50 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-07-02 Cont ID  
Sent By rmcphers Date 2020-07-02 Time 08:03 Rev Time 0.00
Received By rmcphers Date 2020-06-29 Time 10:06 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-06-25 Cont ID  
Sent By rmcphers Date 2020-06-25 Time 12:46 Rev Time 0.00
Received By rmcphers Date 2020-06-23 Time 10:51 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 5 Status P Date 2020-09-16 Cont ID  
Sent By rmcphers Date 2020-09-16 Time 08:44 Rev Time 0.00
Received By rmcphers Date 2020-09-16 Time 08:44 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 4 Status F Date 2020-08-10 Cont ID  
Sent By rmcphers Date 2020-08-10 Time 13:31 Rev Time 0.00
Received By rmcphers Date 2020-08-10 Time 13:31 Sent To  
Notes
2020-08-10 13:31:31SEE BUILDING PLAN REVIEW

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status F Date 2020-07-17 Cont ID  
Sent By rmcphers Date 2020-07-17 Time 14:07 Rev Time 0.00
Received By rmcphers Date 2020-07-17 Time 14:07 Sent To  
Notes
2020-07-17 14:08:11SEE BUILDING PLAN REVIEW

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2020-07-02 Cont ID  
Sent By rmcphers Date 2020-07-02 Time 08:02 Rev Time 0.00
Received By rmcphers Date 2020-07-02 Time 08:02 Sent To  
Notes
2020-07-02 08:03:10WIND DESIGN PRESSURES = DRAWINGS/DOCUMENTS NEED TO BE
 DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR
 ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2020-06-25 Cont ID  
Sent By rmcphers Date 2020-06-25 Time 12:43 Rev Time 0.00
Received By rmcphers Date 2020-06-25 Time 12:43 Sent To  
Notes
2020-06-25 12:45:56WIND DESIGN PRESSURES = DRAWINGS/DOCUMENTS NEED TO BE
 DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR
 ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW.