Plan Review Stops For Permit 20060131 |
Review Stop |
AD |
ADDRESSING |
Rev No |
1 |
Status |
P |
Date |
2020-06-03 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2020-06-03 |
Time |
08:55 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2020-06-03 |
Time |
08:55 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
P |
Date |
2020-09-16 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-09-16 |
Time |
08:44 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-09-16 |
Time |
08:44 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
F |
Date |
2020-08-10 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-08-10 |
Time |
13:30 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-08-10 |
Time |
12:31 |
Sent To |
|
|
Notes |
2020-08-10 12:39:36 | WINDOWS/DOORS/SHUTTERS | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected]. | | CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1 | | AMENDMENTS | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | 1) THE 10 STORY BUILDING WOULD USE A MEAN ROOF HEIGHT | | OF 120 PER THE WIND DESIGN PRESSURE CHART PROVIDED. | | 2) THE SLIDING GLASS DOOR SHOWN IN WIND ZONE 5 DOES NOT | | MEET THE REQUIRED WIND PRESSURES OF (-100.9) PER THE | | CHART PROVIDED. (CANNOT USE A SHUTTER TO MAKE UP FOR | | THE REQUIRED PRESSURES ON THE DOOR) | | 3) THE SHUTTER NUMBER 13 DOES NOT MEET THE REQUIRED | | WIND DESIGN PRESSURES (THERE IS NO ON CENTER SPACING | | FOR 8 FOOT SPAN, (-100.9), USING (G) AT THE TOP). | | 4) SHUTTER NUMBER 1 = THE ON CENTER SPACING FOR THE (G) | | TOP SHOWN ON THE SHUTTER ATTACHMENT FORM IS INCORRECT | | (SHOULD BE 8 INCHES ON CENTER) | | 5) PLEASE SHOW THE ENTIRE BUILDING LENGTH AND WIDTH - | | NEEDED TO DETERMINE WIND ZONES 4 AND 5. | | 6) PLEASE UPDATE YOUR WINDOW SCHEDULE - YOU SHOW THE | | BUILDING LESS THAN 70 FEET HIGH. WIND DESIGN PRESSURES | | ARE BASED ON THE BUILDING ROOF HEIGHT (THE BUILDING | | APPEARS TO BE 10 STORIES WHICH WOULD BE APPROXAMETLY | | 100 FEET HIGH). | | 7) THE WIND DESIGN PRESSURE CHART NEEDS TO BE SIGNED | | ELECTRONICALLY BY THE ENGINEER - SEE FYI BELOW. | | | | THE BEST WAY TO REACH ME IS BY E MAIL (PLEASE E MAIL | | QUESTIONS TO [email protected]) | | | | FYI = SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO | | BE DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR | | ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW. | | DRAWINGS DO NOT SHOW IN "ADOBE READER" AS | | DIGITALLY/ELECTRONICALLY SIGNED. - OR - IF YOUR | | ENGINEER DOES NOT HAVE AN ELECTRONIC OR DIGITAL | | SIGNATURE - PLEASE DROP OFF (CITY HALL DROP BOX) THE | | ORIGINAL SIGNED AND SEALED DRAWINGS/DOCUMENTS ALONG | | WITH A "PLAN REVIEW REQUEST FORM" EXPLAINING THE REASON | | FOR SUBMITTING THE DOCUMENT OR DRAWINGS. PLAN REVIEW | | REQUEST FORM CAN BE OBTAINED BY E MAILING [email protected] | | AND ASKING FOR THE FORM. (AT THIS TIME DROP BOX ITEMS | | MAY TAKE 2 TO 3 WEEKS TO PROCESS, TO SEND TO PLAN | | REVIEW - DUE TO LIMITED STAFF INSIDE THE BUILDING | | DEPT.) |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2020-07-17 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-07-17 |
Time |
13:43 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-07-17 |
Time |
13:43 |
Sent To |
|
|
Notes |
2020-07-17 13:54:24 | WINDOWS/DOORS/SHUTTERS | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected]. | | CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1 | | AMENDMENTS | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | 1) BUILDING APPEARS TO BE OVER 60 FEET HIGH - THE WIND | | DESIGN PRESSURES PROVIDED ARE FOR A BUILDING LESSTHAN | | 60 FEET HIGH - PLEASE PROVIDE THE CORRECT SIGNED AND | | SEALED WIND DESIGN PRESSURES FROM AN ARCHITECT OR | | ENGINEER FOR THIS BUILDING FBC 1609. | | 2) PLEASE PROVIDE A FLOOR PLAN SHOWING THE LOCATION ON | | THE UNIT WITHIN THE BUILDING - NEEDED TO DETERMINE THE | | WIND ZONES 4 OR 5. | | 3) IF THE UNIT IS AN END UNIT PLEASE SHOW THE DISTANCE | | FROM THE CORNER OF THE BUILDING TO THE EDGE OF THE | | CORNER WINDOWS OR DOORS - NEEDED TO DETERMINE IF IN | | WIND ZONE 4 OR 5. | | 4) PLEASE SHOW THE ENTIRE BUILDING LENGTH AND WIDTH - | | NEEDED TO DETERMINE WIND ZONES 4 AND 5. | | 5) PLEASE UPDATE YOUR WINDOW SCHEDULE - YOU SHOW THE | | BUILDING LESSTHAN 55 FEET HIGH. WIND DESIGN PRESSURES | | ARE BASED ON THE BUILDING ROOF HEIGHT (THE BUILDING | | APPEARS TO BE 10 STORIES). | | | | FYI = SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO | | BE DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR | | ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW. | | DRAWINGS DO NOT SHOW IN "ADOBE READER" AS | | DIGITALLY/ELECTRONICALLY SIGNED. - OR - IF YOUR | | ENGINEER DOES NOT HAVE AN ELECTRONIC OR DIGITAL | | SIGNATURE - PLEASE DROP OFF (CITY HALL DROP BOX) THE | | ORIGINAL SIGNED AND SEALED DRAWINGS/DOCUMENTS ALONG | | WITH A "PLAN REVIEW REQUEST FORM" EXPLAINING THE REASON | | FOR SUBMITTING THE DOCUMENT OR DRAWINGS. PLAN REVIEW | | REQUEST FORM CAN BE OBTAINED BY E MAILING [email protected] | | AND ASKING FOR THE FORM. (AT THIS TIME DROP BOX ITEMS | | MAY TAKE 2 TO 3 WEEKS TO PROCESS, TO SEND TO PLAN | | REVIEW - DUE TO LIMITED STAFF INSIDE THE BUILDING | | DEPT.) | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2020-07-02 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-07-02 |
Time |
08:02 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-07-02 |
Time |
08:02 |
Sent To |
|
|
Notes |
2020-07-02 08:02:21 | WINDOWS/DOORS/SHUTTERS | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected]. | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | 1) PLEASE SHOW ON THE FLOOR PLAN THE WINDOW, DOOR AND | | SHUTTER LOCATIONS (WHAT GOES WHERE) AND SIZES (WIDTH | | AND HEIGHT). | | 2) PLEASE SHOW THE DISTANCE FROM THE CORNER OF THE | | BUILDING TO THE EDGE OF THE WINDOWS TO DETERMINE IF IN | | WIND ZONE 4 OR 5. | | 3) FBC R 301, COMPLETE THE FORM PROVIDED AT THE FRONT | | COUNTER "SCHEDULE FOR INSTALLATION OF OPENING | | PROTECTIVE DEVICES OR ASSEMBLIES" OR PROVIDE ALL | | INFORMATION REQUIRED IN ANOTHER FORMAT (SUCH AS EXCEL | | SPREADSHEET). WHEN COMPLETING THE INSTALLATION | | SCHEDULE, PLEASE NOTE FACTORS APPLY DEPENDING ON | | SUBSTRATE, EDGE DISTANCE AND FASTENER. FOR FASTENER, IF | | USING TAPCON, BE SPECIFIC AS TO WHICH TAPCON (TAPCON | | W/ADVANCED THREADFORM TECHNOLOGY REQUIRES A .9 FACTOR). | | FORMS CAN BE PROVIDED BY EMAILING AND ASKING FOR | | "SCHEDULE FOR INSTALLATION OF OPENING PROTECTIVE | | DEVICES OR ASSEMBLIES" AT [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2020-06-25 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-06-25 |
Time |
12:43 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-06-25 |
Time |
12:33 |
Sent To |
|
|
Notes |
2020-06-25 12:43:14 | WINDOWS/DOORS/SHUTTERS | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected]. | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | 1) PLEASE SHOW ON THE FLOOR PLAN THE WINDOW, DOOR AND | | SHUTTER LOCATIONS (WHAT GOES WHERE) AND SIZES (WIDTH | | AND HEIGHT). | | 2) PLEASE SHOW THE DISTANCE FROM THE CORNER OF THE | | BUILDING TO THE EDGE OF THE WINDOWS TO DETERMINE IF IN | | WIND ZONE 4 OR 5. | | 3) FBC R 301, COMPLETE THE FORM PROVIDED AT THE FRONT | | COUNTER "SCHEDULE FOR INSTALLATION OF OPENING | | PROTECTIVE DEVICES OR ASSEMBLIES" OR PROVIDE ALL | | INFORMATION REQUIRED IN ANOTHER FORMAT (SUCH AS EXCEL | | SPREADSHEET). WHEN COMPLETING THE INSTALLATION | | SCHEDULE, PLEASE NOTE FACTORS APPLY DEPENDING ON | | SUBSTRATE, EDGE DISTANCE AND FASTENER. FOR FASTENER, IF | | USING TAPCON, BE SPECIFIC AS TO WHICH TAPCON (TAPCON | | W/ADVANCED THREADFORM TECHNOLOGY REQUIRES A .9 FACTOR). | | FORMS CAN BE PROVIDED BY EMAILING AND ASKING FOR | | "SCHEDULE FOR INSTALLATION OF OPENING PROTECTIVE | | DEVICES OR ASSEMBLIES" AT [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2020-09-16 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-09-16 |
Time |
08:44 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-09-14 |
Time |
09:28 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2020-08-10 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-08-10 |
Time |
13:31 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-08-07 |
Time |
10:12 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2020-07-17 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-07-17 |
Time |
14:08 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-07-13 |
Time |
11:50 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2020-07-02 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-07-02 |
Time |
08:03 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-06-29 |
Time |
10:06 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2020-06-25 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-06-25 |
Time |
12:46 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-06-23 |
Time |
10:51 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
5 |
Status |
P |
Date |
2020-09-16 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-09-16 |
Time |
08:44 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-09-16 |
Time |
08:44 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
4 |
Status |
F |
Date |
2020-08-10 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-08-10 |
Time |
13:31 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-08-10 |
Time |
13:31 |
Sent To |
|
|
Notes |
2020-08-10 13:31:31 | SEE BUILDING PLAN REVIEW |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
F |
Date |
2020-07-17 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-07-17 |
Time |
14:07 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-07-17 |
Time |
14:07 |
Sent To |
|
|
Notes |
2020-07-17 14:08:11 | SEE BUILDING PLAN REVIEW |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
F |
Date |
2020-07-02 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-07-02 |
Time |
08:02 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-07-02 |
Time |
08:02 |
Sent To |
|
|
Notes |
2020-07-02 08:03:10 | WIND DESIGN PRESSURES = DRAWINGS/DOCUMENTS NEED TO BE | | DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR | | ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW. |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2020-06-25 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-06-25 |
Time |
12:43 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-06-25 |
Time |
12:43 |
Sent To |
|
|
Notes |
2020-06-25 12:45:56 | WIND DESIGN PRESSURES = DRAWINGS/DOCUMENTS NEED TO BE | | DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR | | ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW. |
|
|