Plan Review Stops For Permit 20060027 |
Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
Rev No |
3 |
Status |
P |
Date |
2020-06-19 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2020-06-19 |
Time |
07:35 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2020-06-19 |
Time |
07:35 |
Sent To |
|
|
Notes |
|
|
Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
Rev No |
2 |
Status |
F |
Date |
2020-06-18 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2020-06-18 |
Time |
16:01 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2020-06-18 |
Time |
16:01 |
Sent To |
|
|
Notes |
2020-06-18 16:01:41 | LETTER RECEIVED HAS LANGUAGE NOT CONSISTENT WITH THE | | ACKNOWLEDGEMENT REQUESTED IN PREVIOUS PLAN REVIEW, | | REQUESTED THAT IT BE REVISED |
|
|
Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
Rev No |
1 |
Status |
F |
Date |
2020-06-03 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2020-06-03 |
Time |
16:39 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2020-06-03 |
Time |
16:23 |
Sent To |
|
|
Notes |
2020-06-03 16:40:52 | PETER E VALENTI | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6673 | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | FBC M = FBC MECHANICAL | | | | ASBESTOS REVIEW DENIED: | | | | ASBESTOS REQUIREMENTS: | | | | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | CONTRACTOR, ON LETTERHEAD, STATING THAT THE | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | COUNTY WILL BE FOLLOWED AND THAT NOTIFICATION WILL BE | | GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS | | REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE: | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | RENOVATION.HTML | | | | THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO | | [email protected]. THE INFORMATION SHOULD BE IN PDF | | FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE INCLUDE | | THE PERMIT NUMBER AND "ASBESTOS" IN THE SUBJECT LINE. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2020-06-30 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2020-06-30 |
Time |
08:59 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2020-06-30 |
Time |
08:59 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2020-06-04 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2020-06-04 |
Time |
08:29 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2020-06-03 |
Time |
16:24 |
Sent To |
|
|
Notes |
2020-06-04 08:43:39 | PETER E VALENTI | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6673 | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | FBC M = FBC MECHANICAL | | | | BUILDING REVIEW DENIED: | | | | 1) FBC B 107.2.1, PROVIDE INFILL FRAMING DETAILS FOR | | INTERIOR WALLS. PLEASE INCLUDE THE DETAILS FOR DRYWALL | | AND MOISTURE RESISTANT WALL BOARD AT REQUIRED AREAS OF | | SHOWERS AND SINKS. | | | | 2) FBC B 107, PROVIDE THE PRODUCT APPROVALS FOR NEW | | WINDOWS AND MULLIONS. | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2020-06-30 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2020-06-30 |
Time |
09:16 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2020-06-25 |
Time |
12:57 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2020-06-05 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2020-06-05 |
Time |
18:11 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2020-06-05 |
Time |
17:43 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2020-06-23 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2020-06-23 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2020-06-23 |
Time |
11:39 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2020-06-04 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2020-06-04 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2020-06-03 |
Time |
14:54 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2020-06-30 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2020-06-30 |
Time |
09:19 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2020-06-22 |
Time |
11:23 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2020-06-10 |
Time |
|
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2020-06-02 |
Time |
16:30 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
N |
Date |
2020-06-09 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2020-06-09 |
Time |
17:21 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2020-06-09 |
Time |
17:21 |
Sent To |
|
|
Notes |
2020-06-09 17:22:30 | NO MECHANICAL WORK BEING SHOWN ON THIS PROJECT. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2020-06-23 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2020-06-23 |
Time |
12:49 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2020-06-23 |
Time |
12:19 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2020-06-10 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2020-06-10 |
Time |
14:14 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2020-06-10 |
Time |
13:56 |
Sent To |
|
|
Notes |
2020-06-10 14:16:11 | 1ST REVIEW FBC-2017 PLUMBING | | PERMIT- 20060027 | | 6/10/2020 | | | | CODES IN EFFECT: | | FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017 | | FBC ACC- FLORIDA ACCESSIBILITY CODE SIXTH ADDITION 2017 | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | 2017 | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | 2017 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2017 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) SHEET 1: PLEASE PROVIDE A SCOPE OF WORK FOR PLUMBING | | ON THE PLAN- SECTION 107.2.1 WPB. | | | | 2) SHEET 1: PLEASE CLARIFY IF THE EXISTING TUB AND | | SHOWER DRAIN OUTLETS WILL BE RELOCATED TO ACCOMMODATE | | THE NEW SHOWER INSTALLATIONS. IF RELOCATING THE DRAINS | | PLEASE NOTE THE FOLLOWING: | | A) REFER TO SECTION 1002.1 FBC P: THE HORIZONTAL | | DISTANCE FROM THE CENTERLINE OF THE NEW SHOWER DRAIN | | OUTLET TO THE CENTERLINE OF THE INLET OF THE EXISTING | | TRAPS SHALL NOT EXCEED 30?. PLEASE PLACE A NOTE ON THE | | PLAN INDICATING COMPLIANCE. | | B) RELOCATING THE SHOWER DRAIN OUTLETS WILL REQUIRE THE | | FLOOR TO BE X-RAYED TO IN ORDER TO LOCATE REINFORCING | | STEEL OR POST STRESSED FLOOR TENDONS. PLEASE PLACE A | | NOTE ON THE PLANS TO VERIFY COMPLIANCE WILL BE MET- | | SECTION 107.2.1 WPB. | | C) NEW DRAIN PIPE PENETRATIONS OF THE EXISTING SLAB | | WILL REQUIRE FIRESTOPPING TO SEAL THE ANNULAR SPACE | | AROUND THE PIPING. PROVIDE A UL TESTED AND APPROVED | | FIRESTOPPING ASSEMBLY DETAIL ON THE PLAN- SECTION | | 714.4.1.2 FBC B. | | | | 3) SHEET 1: PROVIDE A SHOWER PAN DETAIL- SECTION | | 417.5.2 FBC P. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | CHRISTOPHER L. COLE | | MECHANICAL/PLUMBING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | CCOLE@WPB | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
F |
Date |
2020-06-30 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2020-06-30 |
Time |
09:18 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2020-06-30 |
Time |
09:18 |
Sent To |
|
|
Notes |
2020-06-30 09:19:22 | VERSION 2 IS NOT DIGITALLY SIGNED JLEAHY |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2020-06-03 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2020-06-03 |
Time |
16:41 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2020-06-03 |
Time |
16:24 |
Sent To |
|
|
Notes |
|
|